Your advantages
Wilo CC-HVAC BM

Your advantages

  • Easy operation: User-oriented menu navigation with multilingual plain text display and/or symbol guidance.
  • Easy-to-use system: Saves and outputs operating data, displays and saves error messages.
  • Reliable system: Conductivity test of the transmitter paths, motor protection, status indicator for drives.
  • Advanced settings: 3 adjustable setpoints, PID controller.
  • Optional modules for connection to bus systems: Profibus, BACnet, CANBus, Modbus RTU, LON and others.
Series description

Design

Comfort control system for all conventional pumps in glandless and glanded design with fixed speeds and threephase motors.

Application

For continuous power adjustment to the variable operating states of single, twin-head or multi-pump systems (up to 6 pumps). Controlling depends on the differential pressure Δp, feed/return temperature (±T) or differential temperature (ΔT), including the free adjustment of the duty point by means of preadjustment of the full-load pump output.

Equipment/function

How it works

Wilo Comfort Control Systems enable the infinitely variable electronically controlled power adjustment of pumps to the variable operating statuses of the hydraulic system, depending on the pressure (p), volume flow (Q) and temperature (T) control variables.

Equipment features

  • PID controller
  • Integrated real time clock with summer/winter time switchover
  • Integrated individual/total elapsed time indicator
  • Service life optimisation for multi-pump systems
  • Motor protection by connection of WSK, PTC TS and TSA
  • Multi-colour touch display with backlight
  • Status display for drives (e.g. pumps and frequency converters)
  • User-oriented menu navigation with multi-language plain text display and/or symbol navigation
  • Storage and display of extensive operating data
  • Defined display of error messages and storage in the history memory
  • Conductivity test of the transmitter paths

Typekey

NO VALUE

Technical data

  • Device versions
    • Wall fixation (WM) up to P2 = 4 kW
    • Floor model (BM) from P2 = 5.5 kW
    • Version for control panel installation on request
  • Protection class IP54
  • Mains connection 3~400 V, 50 Hz
  • for pumps with a rated power of P2 = 1.1 to 45 kW (higher power and other voltages on request)
  • Speed control range of 100 % and 30 % of the rated motor speed
  • Power factor cos φ of > 0.90
  • Efficiency at Pmax of > 0.93 and within the permissible partial load range of > 0.85
  • Output voltage of 3 x 130 V – 400 V
  • Output frequency of (10 Hz) 12 Hz – 50/60 Hz
  • Permitted ambient temperature 0 °C to +40 °C

Configuration

NO VALUE

Product selection