Wilo-EMU polder pumps

Series description

Your advantages

  • Deep water lowering using self-cooling motors
  • Long service life thanks to heavy-duty version made of grey cast iron or bronze
  • Compact design
  • Rewindable motors with easy maintenance
  • Hydraulics can be coated with Ceram CT to boost efficiency.
  • The Ceram CP coating is optionally available, prevents deposits and prolongs the service life.

Construction

Multistage submersible pump as a polder pump for vertical installation

Application

  • Drinking water and industrial water from tanks or shallow bodies of water
  • Municipal water supply
  • Sprinkling and irrigation
  • Lowering of the water level
  • Industrial applications
  • Utilisation of geothermal energy
  • Utilisation in offshore areas

Equipment/function

  • Multistage submersible pump with semi-axial impellers
  • Hydraulics and motor freely configurable, depending on power requirements
  • Three-phase motor for direct or star-delta start
  • Rewindable motors

Scope of delivery

  • Hydraulics + motor completely assembled
  • Connection cable approved for drinking water, cable cross-section and length per standard design or per customer request
  • Installation and operating instructions

Type key

Example:

Wilo-EMU K 127P-3 + M 9-2/75

Hydraulics:

K 127P-3

K127

Hydraulics type

P

Construction form: Polder pump

3

Number of hydraulic stages

Motor:

M 9-2/75

M

Submersible motor with special construction for polder pump applications

9

Size (8... = 8"; 9... = 10"; 12... = 12"; 15... = 16")

2

Number of poles

75

Package length

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Fluid temperature: 20 °C, higher temperature upon request
  • Minimum flow across outside shroud: not necessary
  • Max. sand content: 35 g/m3
  • Max. number of starts: 10/h
  • Protection class: IP68
  • Control range for frequency converter:
    • 2-pole: 25 – 50 Hz
    • 4-pole: 30 – 50 Hz

Description/construction

Polder pump for vertical installation.

Hydraulics

Multistage polder pump with semi-axial hydraulics. Housing parts made of EN-GJL with 2K-coating or G-CuSn10, impellers made of NiAl-Bz. Pressure connection as flange connection.

Motor

Motor above the hydraulics, surrounded by a flow shroud. Fluid flows around the motor during operation, permitting surfacing of the motor.

Three-phase motor with rewindable PVC-insulated winding for direct and star-delta starting. Motor shroud made of A2/A4-quality stainless steel or steel/G-CuSn10. Standard pump connection. Sealing of motor shaft achieved through the use of a double mechanical seal made of solid silicon carbide material.

Thrust bearing with rockers for absorption of high axial thrust. Negative axial thrust is absorbed by the counter-thrust bearing. Self-lubricating bearing. Motors are filled with water-glycol mixture as standard. Alternatively, they can be filled with drinking water (T version). Frequency converter operation is permitted (SF 1.1).

Cooling

The internal motor is cooled by the fluid. The limit values for maximum fluid temperature and minimum flow velocity must be adhered to. The volume flow must not be interrupted during operation.

Downloads

REACH regulation

Edition 2018-10
Page format 209.9 x 296.7 mm
Number of pages 4

PDF (581 kB)

Download

General overview 2019 International version

Article Number 2200591
Edition 2018
Version number 1
Page format 209.9 x 297.0 mm
Number of pages 74

PDF (42 MB)