Wilo-Actun FIRST-SPU4
Series description


Your advantages
- Durable, as all parts that come into contact with the fluid are non-corrosive.
- Integrated non-return valve
- Low-wearing due to floating impellers
- Easy maintenance motor
Construction
Multistage 4" submersible pump with a shroud design for vertical and horizontal installation
Application
- For water supply from boreholes and rainwater reservoirs
- For domestic water supply, sprinkling and irrigation
- Pressure boosting
- Lowering of the water level
- For pumping water without long-fibre, abrasive constituents
Equipment/function
- Multistage submersible pump with radial and semi-axial impellers
- Rewindable, oil-filled motor
- Integrated non-return valve
- NEMA coupling
- Single-phase or three-phase AC motor
Scope of delivery
- Hydraulics + motor completely assembled
- 2.0/2.5 m connection cable (cross-section: 4 x 1.5 mm2)
- Installation and user manual
Type key
E.g. | Wilo-Actun FIRST SPU4.01-10-B/XI4-50-1-230 |
Actun | Product family |
FIRST | Series designation |
SPU | Type name (“Submersible pump for universal use” with plastic impellers) |
4 | Pump nominal diameter in inches |
01 | Rated flow rate in m³/h |
10 | Number of stages |
B | Technical generation |
XI | Identifies a fitted motor, series with predominantly rust-free steel (inox) |
4 | Motor nominal diameter in inches |
50-1-230 | Electric version; 50 Hz, 1~ 230 V |
Technical data
- Mains connection: 3~400 V, 50 Hz
- Submerged operating mode: S1
- Fluid temperature: 3-30 °C
- Minimum flow rate at motor: 0.2 m/s or 0.5 m/s (depending on performance)
- Max. sand content: 150 g/m3
- Max. number of starts: 10 -20/h (depending on performance)
- Max. immersion depth: 200 m
- Protection class: IP68
- Pressure connection: NPT 3 to NPT 6
Materials
- Hydraulics housing: Stainless steel 1.4301
- Impellers: Noryl
- Pump shaft: 1.4104 stainless steel
- 1.4301 stainless steel motor housing
- Motor shaft: 1.4305 stainless steel
Description/construction
Submersible pump for vertical and horizontal installation.
Hydraulics
Multistage submersible pump with radial or semi-axial impellers with a shroud design. Integrated non-return valve. All parts that come into contact with the fluid are made from corrosion-resistant materials.
Motor
Rewindable, corrosion-resistant alternating current motor or three-phase current motor for direct starting. Sealed using a mechanical seal with self-lubricating bearings with oil filling.
Cooling
The motor is cooled by the fluid. The motor must always be immersed when operated. The limit value for the maximum fluid temperature may not be exceeded. The limit value for the minimum volume flow may not be exceeded. Vertical installation is possible with or without cooling shroud. A cooling shroud is required for horizontal installation.
Duty chart
Wilo-Actun FIRST SPU 4