Flumen EXCEL-TRE 20.145-4/13 S7
Data sheet
Unit
-
Power consumption at duty point P1.10.57 kW
-
Max. thrust F105 N
-
Thrust to power ratio184 N/kW
-
Max. weight* m40 kg
-
Explosion protection ATEXoptional
-
Explosion protection FMoptional
-
Protection class motorIP68
Propeller
-
Propeller model3-blade propeller with self-cleaning hub; backward-curved as a result clogging- and entwining-free
-
Nominal propeller diameter Dnom200 mm
-
Propeller speed n1416 1/min
-
Transmission ratio1.000
Filling quantities and types
-
Filling sealing chamberWhite oil
-
Fill volume sealing chamber V0.40 l
Motor/electronics
-
Motor typeTE 12-4/13GRF (Ex)
-
Motor designSubmersible motor acc. IEC 60034-1
-
Mains connection3~400 V, 50 Hz
-
Rated current IN2.95 A
-
Starting current - direct IA14 A
-
Power consumption P1 max1.40 kW
-
Rated power P21.10 kW
-
Speed original n1416 1/min
-
Motor efficiency classIE3
-
Efficiency ηM78.0 Percentage
-
Power factor cos φ0.69
-
Min. fluid temperature Tmin3 °C
-
Max. fluid temperature Tmax40 °C
-
Max. immersion depth20.00 m
-
Insulation classF/B (optionally H/B)
-
Max. switching frequency t15 1/h
-
min. switching break t3 min
-
Starting torque M18.3 Nm
-
Moment of inertia0.00210 kg/m²
-
Motor bearings2 grooved ball bearing
Materials
-
Motor housingStainless steel
-
Static gasketsFKM
-
Motor shaft1.4021, X20Cr13
-
Sealing chamber1.4408, GX5CrNiMo19-11-2
-
Seal on the fluid sideSiC/SiC, Q1Q1VGG
-
Propeller1.4408, GX5CrNiMo19-11-2
Information for order placements
-
BrandWilo
-
Product descriptionFlumen EXCEL-TRE 20.145-4/13 S7
-
Article numberTRE_20_145-4_13_S7_400_50
-
Net weight, approx. m40 kg
Options
-
Explosion protection typeATEX, FM
-
Motor protectionBimetallic
Dimensions and dimensions drawings
WILO-Flumen Excel-TRE 20


Ordering information
Information for order placements
-
BrandWilo
-
Product descriptionFlumen EXCEL-TRE 20.145-4/13 S7
-
Article numberTRE_20_145-4_13_S7_400_50
-
Net weight, approx. m40 kg
-
Date of sales availability2010-01-01
-
Date of introduction2010-01-01
Downloads