Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
SC/SC-FC-HVAC system | Wilo
Your advantages
Wilo-SCe-HVAC system

Your advantages

  • Easy operation: Display, symbols and menu navigation analogous to the Wilo glanded pumps of the latest design
  • Easy-to-use system: System access to the service menu protected via code, error history code with up to 16 individual messages
  • Reliable system: Permanent display of pumps and system status as well as the actual value present in the display
  • SBM and SSM as standard, other error messages/alarm signals can optionally be output via relay or via other communication tools (e.g., bus systems)
  • Advanced settings: 2 adjustable setpoints, remote setpoint adjustment possible
  • Communication capability: Connectible bus systems: BACnet, Modbus RTU (RS 232) (LON connectible via optional module)
Series description

Design

Digitally controlled, variable Smart control systems for driving glandless and glanded pumps of all makes and single and multi-pump systems. SC version: Control of fixed speed pumps via contactors (cascade connection). SC-FC version: Control of fixed speed pumps via contactors (cascade connection), but control of a pump via frequency converter as a base-load pump, control of the peak-load pumps in cascade connection

Application

For continuous power adjustment to the variable operating states of single, twin-head or multi-pump systems (up to 4 pumps). Controlling depends on the differential pressure Δp, feed/return temperature (±T) or differential temperature (ΔT), including the free adjustment of the duty point by means of preadjustment of the full-load pump output.

Documents

RCM

RCM 2215573

Number of pages 1
PDF (102 KB)
Product selection
Product descriptionMax. number of controllable pumpsMax. rated current per pump IArticle number
SC-HVAC system 2x37,5A-WM (star-delta-starting)
2
37.5 A
2545371
SC-HVAC system 2x43A-WM (star-delta-starting)
2
43 A
2545375
SC-HVAC system 3x1,6A-WM (direct starting)
3
1.6 A
2545312
SC-HVAC system 3x2,4A-WM (direct starting)
3
2.4 A
2545316
SC-HVAC system 3x4A-WM (direct starting)
3
4 A
2545320
SC-HVAC system 3x6,3A-WM (direct starting)
3
6.3 A
2545324
SC-HVAC system 3x10A-WM (direct starting)
3
10 A
2545328
SC-HVAC system 3x12A-WM (direct starting)
3
12 A
2545332
SC-HVAC system 3x13A-WM (star-delta-starting)
3
13 A
2545352
SC-HVAC system 3x16A-WM (star-delta-starting)
3
16 A
2545356
SC-HVAC system 3x16A-WM (direct starting)
3
16 A
2545336
SC-HVAC system 3x19A-WM (star-delta-starting)
3
19 A
2545360
SC-HVAC system 3x20A-WM (direct starting)
3
20 A
2545340
SC-HVAC system 3x24A-WM (star-delta-starting)
3
24 A
2545364
SC-HVAC system 3x24A-WM (direct starting)
3
24 A
2545344
SC-HVAC system 3x32A-BM (star-delta-starting)
3
32 A
2545368
SC-HVAC system 3x32A-WM (direct starting)
3
32 A
2545348
SC-HVAC system 3x37,5A-BM (star-delta-starting)
3
37.5 A
2545372
SC-HVAC system 3x43A-BM (star-delta-starting)
3
43 A
2545376
SC-HVAC system 4x1,6A-WM (direct starting)
4
1.6 A
2545313
SC-HVAC system 4x2,4A-WM (direct starting)
4
2.4 A
2545317
SC-HVAC system 4x4A-WM (direct starting)
4
4 A
2545321
SC-HVAC system 4x6,3A-WM (direct starting)
4
6.3 A
2545325
SC-HVAC system 4x10A-WM (direct starting)
4
10 A
2545329
SC-HVAC system 4x12A-WM (direct starting)
4
12 A
2545333
SC-HVAC system 4x13A-WM (star-delta-starting)
4
13 A
2545353
SC-HVAC system 4x16A-WM (star-delta-starting)
4
16 A
2545357
SC-HVAC system 4x16A-WM (direct starting)
4
16 A
2545337
SC-HVAC system 4x19A-WM (star-delta-starting)
4
19 A
2545361
SC-HVAC system 4x20A-WM (direct starting)
4
20 A
2545341
SC-HVAC system 4x24A-WM (star-delta-starting)
4
24 A
2545365
SC-HVAC system 4x24A-WM (direct starting)
4
24 A
2545345
SC-HVAC system 4x32A-BM (star-delta-starting)
4
32 A
2545369
SC-HVAC system 4x32A-WM (direct starting)
4
32 A
2545349
SC-HVAC system 4x37,5A-BM (star-delta-starting)
4
37.5 A
2545373
SC-HVAC system 4x43A-BM (star-delta-starting)
4
43 A
2545377