SC(E)2.0 OPTION BACNET MSTP/ MODBUS RTU
Technical data | |
---|---|
Rated voltage U | 5 V |
Voltage tolerance | 0 % |
Protection class | IP20 |
Min. storage temperature | -10 °C |
Max. storage temperature | 60 °C |
Min. ambient temperature | 0 °C |
Max. ambient temperature | 40 °C |
Prices | |
---|---|
Price (excl. VAT) | on request |
Product data | |
---|---|
Brand | Wilo |
Product description | SC(E)2.0 OPTION BACNET MSTP/ MODBUS RTU |
Article number | 4255869 |
EAN number | 4062679393582 |
Minimum order quantity | 1 |
Date of sales availability | 2024-03-18 |
Packaging | |
---|---|
Packaging type | Cardboard box |
Packaging property | Transport packaging |
Pieces per pallet | 1 |
Number per layer | 1 |
Dimension, weight | |
---|---|
Length with packaging | 205 mm |
Length L | 102.5 mm |
Height with packaging | 50 mm |
Height H | 6.2 mm |
Width with packaging | 255 mm |
Width W | 93.1 mm |
Gross weight, approx. m | 0.2 kg |
Net weight, approx. m | 0.1 kg |
BACnet MSTP
For connecting Wilo-SiBoostSmart2.0 systems with BACnet-MSTP networks.
The SC2.0-OPTION BACnet-MSTP communication module is a hardware extension for integrating an SC(e)2.0 system as a participant in the existing BACnet building automation. The connection of the BACnet-MSTP module to the RS485 bus takes place via twisted-pair cabling. BACnet (Building Automation and Control Networks) ensures interoperability between devices from different manufacturers. With BACnet-MSTP, different parameters can be read and written, e.g. switchgear data, pump status and modes, actual values, setpoints, the current speed of the pump, measured temperatures (HVAC only), operating hours, switching cycles, etc.
Subsequent installation of the BACnet-MSTP function in the switchgear is possible. The version by Wilo customer service is recommended.
Modbus RTU:
For connecting Wilo-SiBoostSmart2.0 systems with Modbus RTU networks.
The SC2.0-OPTION Modbus RTU communication module is a hardware extension for integrating an SC(e)2.0 system as a participant in the existing Modbus RTU building automation. The connection of the Modbus RTU module to the RS485 bus takes place via twisted-pair cabling. Modbus RTU warrants interoperability between devices from different manufacturers. With Modbus RTU, different parameters can be read and written, e.g. switchgear data, pump status and modes, actual values, setpoints, the current speed of the pump, measured temperatures (HVAC only), operating hours, switching cycles, etc.
Subsequent installation of the Modbus RTU function in the switchgear is possible. The version by Wilo customer service is recommended.
Scope of delivery:
- Adapter
- Installation and operating instructions
Technical data | |
---|---|
Rated voltage U | 5 V |
Protection class | IP20 |
Max. ambient temperature | 40 °C |
Min. ambient temperature | 0 °C |
Length L | 102.5 mm |
Width W | 93.1 mm |
Height H | 6.2 mm |
Net weight, approx. | 0.1 kg |
Make | Wilo |
Item no. | 4255869 |