Otsing
Võtke ühendust
E-post
Kataloogi loomine
Minu lemmikud
Tootevõrdlus
SC/SC-FC-HVAC system | Wilo
Your advantages
Wilo-SCe-HVAC system

Your advantages

  • Easy operation: Display, symbols and menu navigation analogous to the Wilo glanded pumps of the latest design
  • Easy-to-use system: System access to the service menu protected via code, error history code with up to 16 individual messages
  • Reliable system: Permanent display of pumps and system status as well as the actual value present in the display
  • SBM and SSM as standard, other error messages/alarm signals can optionally be output via relay or via other communication tools (e.g., bus systems)
  • Advanced settings: 2 adjustable setpoints, remote setpoint adjustment possible
  • Communication capability: Connectible bus systems: BACnet, Modbus RTU (RS 232) (LON connectible via optional module)

Recommended services

Series description

Design

Digitally controlled, variable Smart control systems for driving glandless and glanded pumps of all makes and single and multi-pump systems. SC version: Control of fixed speed pumps via contactors (cascade connection). SC-FC version: Control of fixed speed pumps via contactors (cascade connection), but control of a pump via frequency converter as a base-load pump, control of the peak-load pumps in cascade connection

Application

For continuous power adjustment to the variable operating states of single, twin-head or multi-pump systems (up to 4 pumps). Controlling depends on the differential pressure Δp, feed/return temperature (±T) or differential temperature (ΔT), including the free adjustment of the duty point by means of preadjustment of the full-load pump output.

Documents

Installation and operating instructions

Wilo-Control SC-HVAC (SC, SC-FC, SCe)

Article Number 2542066
Edition 2014 02
Number of pages 57
Language en
PDF (3 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (271 KB)

CE

CE 3335004-02

Number of pages 4
Language language neutral
PDF (336 KB)

CE 2117792-07

Number of pages 6
Language language neutral
PDF (213 KB)
Product selection
Product description Max. number of controllable pumps Max. rated current per pump IArticle number Price (excl. VAT)
SC-FC-HVAC system 3x43A-FC-BM (star-delta-starting)
3
43 A
2545492
on request
SC-FC-HVAC system 4x1,6A-FC-WM (direct starting)
4
1.6 A
2545429
on request
SC-FC-HVAC system 4x2,4A-FC-WM (direct starting)
4
2.4 A
2545433
on request
SC-FC-HVAC system 4x4A-FC-WM (direct starting)
4
4 A
2545437
on request
SC-FC-HVAC system 4x6,3A-FC-WM (direct starting)
4
6.3 A
2545441
on request
SC-FC-HVAC system 4x10A-FC-WM (direct starting)
4
10 A
2545445
on request
SC-FC-HVAC system 4x12A-FC-BM (direct starting)
4
12 A
2545449
on request
SC-FC-HVAC system 4x13A-FC-BM (star-delta-starting)
4
13 A
2545469
on request
SC-FC-HVAC system 4x16A-FC-BM (direct starting)
4
16 A
2545453
on request
SC-FC-HVAC system 4x16A-FC-BM (star-delta-starting)
4
16 A
2545473
on request
SC-FC-HVAC system 4x19A-FC-BM (star-delta-starting)
4
19 A
2545477
on request
SC-FC-HVAC system 4x20A-FC-BM (direct starting)
4
20 A
2545457
on request
SC-FC-HVAC system 4x24A-FC-BM (direct starting)
4
24 A
2545461
on request
SC-FC-HVAC system 4x24A-FC-BM (star-delta-starting)
4
24 A
2545481
on request
SC-FC-HVAC system 4x32A-FC-BM (direct starting)
4
32 A
2545465
on request
SC-FC-HVAC system 4x32A-FC-BM (star-delta-starting)
4
32 A
2545485
on request
SC-FC-HVAC system 4x37,5A-FC-BM (star-delta-starting)
4
37.5 A
2545489
on request
SC-FC-HVAC system 4x43A-FC-BM (star-delta-starting)
4
43 A
2545493
on request
SC-HVAC system 1x1,6A-WM (direct starting)
1
1.6 A
2545310
on request
SC-HVAC system 1x2,4A-WM (direct starting)
1
2.4 A
2545314
on request
SC-HVAC system 1x4A-WM (direct starting)
1
4 A
2545318
on request
SC-HVAC system 1x6,3A-WM (direct starting)
1
6.3 A
2545322
on request
SC-HVAC system 1x10A-WM (direct starting)
1
10 A
2545326
on request
SC-HVAC system 1x12A-WM (direct starting)
1
12 A
2545330
on request
SC-HVAC system 1x13A-WM (star-delta-starting)
1
13 A
2545350
on request
SC-HVAC system 1x16A-WM (star-delta-starting)
1
16 A
2545354
on request
SC-HVAC system 1x16A-WM (direct starting)
1
16 A
2545334
on request
SC-HVAC system 1x19A-WM (star-delta-starting)
1
19 A
2545358
on request
SC-HVAC system 1x20A-WM (direct starting)
1
20 A
2545338
on request
SC-HVAC system 1x24A-WM (star-delta-starting)
1
24 A
2545362
on request
SC-HVAC system 1x24A-WM (direct starting)
1
24 A
2545342
on request
SC-HVAC system 1x32A-WM (star-delta-starting)
1
32 A
2545366
on request
SC-HVAC system 1x32A-WM (direct starting)
1
32 A
2545346
on request
SC-HVAC system 1x37,5A-WM (star-delta-starting)
1
37.5 A
2545370
on request
SC-HVAC system 1x43A-WM (star-delta-starting)
1
43 A
2545374
on request
SC-HVAC system 2x1,6A-WM (direct starting)
2
1.6 A
2545311
on request
SC-HVAC system 2x2,4A-WM (direct starting)
2
2.4 A
2545315
on request
SC-HVAC system 2x4A-WM (direct starting)
2
4 A
2545319
on request
SC-HVAC system 2x6,3A-WM (direct starting)
2
6.3 A
2545323
on request
SC-HVAC system 2x10A-WM (direct starting)
2
10 A
2545327
on request
SC-HVAC system 2x12A-WM (direct starting)
2
12 A
2545331
on request
SC-HVAC system 2x13A-WM (star-delta-starting)
2
13 A
2545351
on request
SC-HVAC system 2x16A-WM (star-delta-starting)
2
16 A
2545355
on request
SC-HVAC system 2x16A-WM (direct starting)
2
16 A
2545335
on request
SC-HVAC system 2x19A-WM (star-delta-starting)
2
19 A
2545359
on request
SC-HVAC system 2x20A-WM (direct starting)
2
20 A
2545339
on request
SC-HVAC system 2x24A-WM (star-delta-starting)
2
24 A
2545363
on request
SC-HVAC system 2x24A-WM (direct starting)
2
24 A
2545343
on request
SC-HVAC system 2x32A-WM (star-delta-starting)
2
32 A
2545367
on request
SC-HVAC system 2x32A-WM (direct starting)
2
32 A
2545347
on request