SCe-HVAC system 1x13A-WM
Technical data | |
---|---|
Min. rated current I | 10.1 A |
Max. rated current per pump I | 13 A |
Protection class | IP54 |
Activation type | Electronic (E) |
Max. number of controllable pumps | 1 |
Control | Without frequency converter |
Installation | Wall-mounted installation |
Materials | |
---|---|
Material, housing | Steel |
Product data | |
---|---|
Brand | Wilo |
Product description | SCe-HVAC system 1x13A-WM |
Article number | 2545258 |
EAN number | 4048482651019 |
Colour | grey |
Minimum order quantity | 1 |
Date of sales availability | 2010-01-01 |
Packaging | |
---|---|
Packaging type | Cardboard box |
Packaging property | Transport packaging |
Pieces per pallet | 1 |
Number per layer | 1 |
Dimension, weight | |
---|---|
Length with packaging | 270 mm |
Length L | 210 mm |
Height with packaging | 490 mm |
Height H | 400 mm |
Width with packaging | 450 mm |
Width W | 400 mm |
Gross weight, approx. m | 22.3 kg |
Net weight, approx. m | 20.9 kg |
Wilo-Smart Controller for digital, stepless power control of one-pump and multi-pump systems in heating, air-conditioning and ventilation applications. For infinitely variable, electronically controlled pumps or pumps with integrated frequency converter.
Hardware
Fully electronic Wilo-Smart Controller (SCe) in steel sheeting enclosure (colour: pebble grey), comprised of internal power supply, microprocessor with “Soft-SPS”, analogue and digital inputs and outputs, LCD display (backlit) for displaying operating data, control parameters, operating states of the pumps, error messages and history memory. LEDs for display of system status (operation/fault), setting of operating parameters and acknowledgement of fault messages via Green Button Technology, lockable main switch, potential-free contacts for SBM/SSM collective operation and collective fault signals, contacts for external On/Off and 2nd setpoint, conductivity test in the sensor cable. The pump mains power feed is protected via the circuit breaker. Actual value output via a 0-10 V analogue signal for external measurement / display applications, (10 Volt depending on the sensor end value). External remote setpoint adjustment via 4...20 mA signal. Automatic, load-sensitive cut-in of 1 to n peak-load pump(s) depending on the control variables:
- Pressure - constant, p-c
- Differential pressure - constant, dp-c
- Differential pressure - variable, dp-v
- Temperature setter, n = f(Tx)
- Speed setter, n=f(analogue In)
- Differential pressure - constant, dT
Software functions
Fully automatic control for 1 to n pumps (frequency-controlled) by means of setpoint/actual value comparison, 4-20 mA sensor signal (conductivity test) for control variable actual values, menu navigation with symbols and menu numbers.
2 parameter sets can be selected: Easy Menu (setpoint & control mode) or expert Menu (operation and control parameters)
Can be selected by Customer Service with or without standby pump, automatic switching of an operating pump to the reserve pump in the event of a fault, operating mode of the pumps can be selected freely (manual, off, automatic), elapsed time indicator for each pump and system, switching cycle counter for each pump and system.
Monitoring of Max. and Min. values of the system with adjustable delay times and limits, external On/Off via contact for deactivation of the Automatic mode of the system, fault memory of the last 16 faults, setpoint switching of 2nd setpoint can be activated by contact, SBM and SSM logic reversal possible, parameters pre-set at the factory for simple commissioning.
Automatic, configurable pump cycling
- Standard setting: Impulse - The base-load pump is cycled at each new demand, regardless of operating hours
- Alternative: Pump cycling dependent on operating hours, cycling of the base-load pump after the specified operating hours
Automatic pump trial run (pump kick)
- Can be activated
- Time between two pump trial runs is freely programmable
Standards followed
- Electrical Equipment of Machines EN 60204-1
- Low-voltage switchgear combinations EN 61439-1 and 61439-2
- EMC - Immunity for Industrial Environments EN 61000-6-2
- EMC - Emission standard for residential, commercial and light-industrial environments EN 61000-6-3 (for SC-FC only up to 9.0 kW, above this: EN 61000-6-4 Emission standard for industrial environments)
Extra charge for optional modules for connection to BMS and bus systems (installation at the factory or subsequently after technical clarification):
- H-0-A (Manual-Zero-Automatic) switch: preselection of the operating mode of each pump and manual operation in the event of a controller fault “Manual” (emergency/test mode available at mains power, motor protection available), “O” (pump switched off – cannot be switched on using the controller) and “Auto” (pump enabled for automatic mode via the controller)
- Evaluation relay for PTC
- Individual running and fault signals
- Converter 0/2-10 V in 0/4 to 20 mA
- Soft starter for peak-load pumps
- Connection to BMS systems in accordance with VDI 3814
- Bus systems: BACnet, LON, Modbus RTU
Scope of delivery
- Switchgear
- Installation and operating instructions
- Wiring diagram
Technical data | |
---|---|
Max. number of controllable pumps | 1 |
Phases | 3 |
Rated voltage U | 380/400 V |
Mains frequency f |
|
Min. rated current I | 10.1 A |
Max. rated current per pump I | 13 A |
Activation type | Electronic (E) |
Protection class | IP54 |
Min. ambient temperature | 0 °C |
Max. ambient temperature | 40 °C |
Control | Without frequency converter |
Installation | Wall-mounted installation |
Material, housing | Steel |
Length L | 210 mm |
Width W | 400 mm |
Height H | 400 mm |
Net weight, approx. | 20.9 kg |
Make | Wilo |
Item no. | 2545258 |