Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-VeroTwin-DPL | Wilo
Your advantages
Wilo-VeroTwin-DPL

Your advantages

  • Reduction of space required and installation costs due to twin-head pump design
  • Main/standby mode or peak-load operation (by means of external auxiliary device)
  • High standard of corrosion protection thanks to cataphoretic coating
  • Series design: motor with one-piece shaft
  • Version N: standard motor B5 or V1 with stainless steel plug shaft
Series description
VeroTwin-DPL

Design

Glanded double pump in in-line design with flange connection

Application

Pumping of heating water (acc. to VDI 2035), chilled water and water/glycol mixtures without abrasive substances in heating, chilled water and cooling systems.

Typekey

Example

DPL 40/160‐4/2

DPL

In-line double pump

40

Nominal diameter DN of the pipe connection

160

Nominal impeller diameter

4

Nominal motor power P2 in kW

2

Number of poles

Technical data

  • Permissible temperature range -20 °C to +120 °C
  • Mains connection 3~400 V, 50 Hz (others on request)
  • Protection class IP 55
  • Nominal diameter DN 32 to DN 100
  • Max. operating pressure 10 bar (special version: 16 bar)

Materials

  • Pump housing and lantern: EN-GJL-250
  • Impeller: PP fibreglass-reinforced /EN-GJL-200 (depending on pump type)
  • Shaft: 1.4021
  • Mechanical seal: AQ1EGG; other mechanical seals on request

Construction

Single-stage, low-pressure double pump in in-line design with

  • Switchover valve
  • Mechanical seal
  • Flange connection with pressure measuring connection R 1/8
  • Motor with one-piece shaft

Scope of delivery

  • Pump
  • Installation and operating instructions

Options

  • ...-H5 variant with PN16 housing (at additional charge)
  • Other voltages and frequencies as well as ATEX approval on request

Accessories

  • Mounting brackets for installation on a base
  • PTC thermistor sensor, PTC resistor tripping relay
  • Special motors
  • Special mechanical seals
  • SC-HVAC, CC-HVAC control systems and switchgears
  • Blind flanges
Documents

Installation and operating instructions

Wilo-VeroLine-IPL/IPL... N Wilo-VeroTwin-DPL/DPL... N

Article Number 2140029
Edition 2017-11
Number of pages 96
PDF (8 MB)

Wilo-VeroLine-IPL (1,1-7,5 kW) Wilo-VeroTwin-DPL (1,1-7,5 kW)

Article Number 2140036
Edition 2017-11
Number of pages 92
PDF (6 MB)

Consulting manual

Glanded pumps, single-stage, single-volute

Article Number Wilo515021
Edition 2021-12
Number of pages 24
PDF (7 MB)

Certification booklet

Wilo-VeroLine-IP-E, Wilo-VeroTwin-DP-E, Wilo-VeroLine-IPL, Wilo-VeroTwin-DPL, Wilo-VeroLine-IPL-N, Wilo-VeroTwin-DPL-N, Wilo-VeroLine-IPH, Wilo-BM/BM-B/BM-S, Wilo-VeroLine-IP-Z

Article Number 2216679
Edition 2022-11
Number of pages 60
PDF (22 MB)

Reference sheet

Reference Sheet (English) - Power industry - Power Station Anpara, Anpara, India, 2014

Number of pages 2
PDF (2 MB)
Product selection
Number of results: 124
250 … 500 mm
[124]
Product descriptionNumber of polesMEIIENominal flange diameterMechanical sealPort-to-port length L0Rated power P2Gross weight, approx. mArticle numberGRD groupBlind flange
VeroTwin-DPL 32/85-0,37/2
2
≥0.4
IE2
DN 32
AQ1EGG
260 mm
0.37 kW
37.9 kg
2150365
3
F
VeroTwin-DPL 32/85-0,37/2-S1
2
≥0.4
IE2
DN 32
Q1Q1X4GG
260 mm
0.37 kW
37.9 kg
2171170
3
F
VeroTwin-DPL 32/95-0,55/2
2
≥0.4
IE2
DN 32
AQ1EGG
260 mm
0.55 kW
42.5 kg
2150366
3
F
VeroTwin-DPL 32/95-0,55/2-S1
2
≥0.4
IE2
DN 32
Q1Q1X4GG
260 mm
0.55 kW
42.5 kg
2166993
3
F
VeroTwin-DPL 32/105-0,12/4
4
≥0.4
IE2
DN 32
AQ1EGG
260 mm
0.12 kW
36.5 kg
2150372
3
F
VeroTwin-DPL 32/105-0,12/4-S1
4
≥0.4
IE2
DN 32
Q1Q1X4GG
260 mm
0.12 kW
36.5 kg
2171156
3
F
VeroTwin-DPL 32/105-0,75/2
2
≥0.4
IE3
DN 32
AQ1EGG
260 mm
0.75 kW
51.6 kg
2121239
3
F
VeroTwin-DPL 32/105-0,75/2-S1
2
≥0.4
IE3
DN 32
Q1Q1X4GG
260 mm
0.75 kW
51.6 kg
2164244
3
F
VeroTwin-DPL 32/125-1,1/2
2
≥0.4
IE3
DN 32
AQ1EGG
260 mm
1.1 kW
59.2 kg
2121240
3
F
VeroTwin-DPL 32/125-1,1/2-S1
2
≥0.4
IE3
DN 32
Q1Q1X4GG
260 mm
1.1 kW
59.2 kg
2167013
3
F
VeroTwin-DPL 32/135-0,25/4
4
≥0.4
IE2
DN 32
AQ1EGG
260 mm
0.25 kW
36.5 kg
2150373
3
F
VeroTwin-DPL 32/135-0,25/4-S1
4
≥0.4
IE2
DN 32
Q1Q1X4GG
260 mm
0.25 kW
36.5 kg
2171157
3
F
VeroTwin-DPL 32/135-1,1/2
2
≥0.4
IE3
DN 32
AQ1EGG
260 mm
1.1 kW
59.2 kg
2121241
3
F
VeroTwin-DPL 32/135-1,1/2-S1
2
≥0.4
IE3
DN 32
Q1Q1X4GG
260 mm
1.1 kW
59.2 kg
2171171
3
F
VeroTwin-DPL 32/135-1,5/2
2
≥0.4
IE3
DN 32
AQ1EGG
260 mm
1.5 kW
69.6 kg
2155462
3
F
VeroTwin-DPL 32/135-1,5/2-S1
2
≥0.4
IE3
DN 32
Q1Q1X4GG
260 mm
1.5 kW
69.6 kg
2171172
3
F
VeroTwin-DPL 32/165-3/2
2
≥0.4
IE3
DN 32
AQ1EGG
320 mm
3 kW
114 kg
2121242
4
B
VeroTwin-DPL 32/165-3/2-S1
2
≥0.4
IE3
DN 32
Q1Q1X4GG
320 mm
3 kW
113 kg
2171173
4
B
VeroTwin-DPL 32/175-4/2
2
≥0.4
IE3
DN 32
AQ1EGG
320 mm
4 kW
129 kg
2121243
4
B
VeroTwin-DPL 32/175-4/2-S1
2
≥0.4
IE3
DN 32
Q1Q1X4GG
320 mm
4 kW
129 kg
2171174
4
B
VeroTwin-DPL 40/75-0,12/2
2
≥0.4
IE2
DN 40
AQ1EGG
250 mm
0.12 kW
38 kg
2157302
3
G
VeroTwin-DPL 40/75-0,12/2-S1
2
≥0.4
IE2
DN 40
Q1Q1X4GG
250 mm
0.12 kW
38 kg
2199640
3
G
VeroTwin-DPL 40/90-0,37/2
2
≥0.4
IE2
DN 40
AQ1EGG
250 mm
0.37 kW
40.2 kg
2089642
3
G
VeroTwin-DPL 40/115-0,55/2
2
≥0.4
IE2
DN 40
AQ1EGG
250 mm
0.55 kW
42.2 kg
2089643
3
G
VeroTwin-DPL 40/115-0,55/2-S1
2
≥0.4
IE2
DN 40
Q1Q1X4GG
250 mm
0.55 kW
42.2 kg
2072178
3
G
VeroTwin-DPL 40/120-1,5/2
2
≥0.4
IE3
DN 40
AQ1EGG
320 mm
1.5 kW
71.2 kg
2121244
3
F
VeroTwin-DPL 40/120-1,5/2-S1
2
≥0.4
IE3
DN 40
Q1Q1X4GG
320 mm
1.5 kW
71.2 kg
2171175
3
F
VeroTwin-DPL 40/130-0,25/4
4
≥0.4
IE2
DN 40
AQ1EGG
320 mm
0.25 kW
42.7 kg
2089620
3
F
VeroTwin-DPL 40/130-0,25/4-S1
4
≥0.4
IE2
DN 40
Q1Q1X4GG
320 mm
0.25 kW
42.7 kg
2171158
3
F
VeroTwin-DPL 40/130-2,2/2
2
≥0.4
IE3
DN 40
AQ1EGG
320 mm
2.2 kW
73.2 kg
2121245
3
F
VeroTwin-DPL 40/130-2,2/2-S1
2
≥0.4
IE3
DN 40
Q1Q1X4GG
320 mm
2.2 kW
73.2 kg
2171176
3
F
VeroTwin-DPL 40/150-3/2
2
≥0.4
IE3
DN 40
AQ1EGG
320 mm
3 kW
84.2 kg
2121246
3
F
VeroTwin-DPL 40/150-3/2-S1
2
≥0.4
IE3
DN 40
Q1Q1X4GG
320 mm
3 kW
84.2 kg
2171177
3
F
VeroTwin-DPL 40/160-0,37/4
4
≥0.4
IE2
DN 40
AQ1EGG
320 mm
0.37 kW
53.2 kg
2089621
3
F
VeroTwin-DPL 40/160-0,37/4-S1
4
≥0.4
IE2
DN 40
Q1Q1X4GG
320 mm
0.37 kW
53.2 kg
2171159
3
F
VeroTwin-DPL 40/160-4/2
2
≥0.4
IE3
DN 40
AQ1EGG
320 mm
4 kW
106 kg
2121247
3
F
VeroTwin-DPL 40/160-4/2-S1
2
≥0.4
IE3
DN 40
Q1Q1X4GG
320 mm
4 kW
106 kg
2166994
3
F
VeroTwin-DPL 40/165-4/2
2
≥0.4
IE3
DN 40
AQ1EGG
340 mm
4 kW
144.6 kg
2121248
4
B
VeroTwin-DPL 40/165-4/2-S1
2
≥0.4
IE3
DN 40
Q1Q1X4GG
340 mm
4 kW
144.6 kg
2171178
4
B
VeroTwin-DPL 40/175-5,5/2
2
≥0.4
IE3
DN 40
AQ1EGG
340 mm
5.5 kW
172.6 kg
2121249
4
B
VeroTwin-DPL 40/175-5,5/2-S1
2
≥0.4
IE3
DN 40
Q1Q1X4GG
340 mm
5.5 kW
172.6 kg
2171179
4
B
VeroTwin-DPL 40/195-7,5/2
2
≥0.4
IE3
DN 40
AQ1EGG
440 mm
7.5 kW
212.2 kg
2121250
5
C
VeroTwin-DPL 40/195-7,5/2-S1
2
≥0.4
IE3
DN 40
Q1Q1X4GG
440 mm
7.5 kW
212.2 kg
2171180
5
C
VeroTwin-DPL 50/95-0,55/2
2
≥0.4
IE2
DN 50
AQ1EGG
280 mm
0.55 kW
42.2 kg
2152445
3
G
VeroTwin-DPL 50/95-0,55/2-S1
2
≥0.4
IE2
DN 50
Q1Q1X4GG
280 mm
0.55 kW
42.2 kg
2171181
3
G
VeroTwin-DPL 50/105-0,12/4
4
≥0.4
IE2
DN 50
AQ1EGG
280 mm
0.12 kW
40.3 kg
2150374
3
G
VeroTwin-DPL 50/105-0,12/4-S1
4
≥0.4
IE2
DN 50
Q1Q1X4GG
280 mm
0.12 kW
40.3 kg
2171160
3
G
VeroTwin-DPL 50/105-0,75/2
2
≥0.4
IE3
DN 50
AQ1EGG
280 mm
0.75 kW
49.5 kg
2155465
3
G
VeroTwin-DPL 50/105-0,75/2-S1
2
≥0.4
IE3
DN 50
Q1Q1X4GG
280 mm
0.75 kW
49.5 kg
2171182
3
G
VeroTwin-DPL 50/120-1,5/2
2
≥0.4
IE3
DN 50
AQ1EGG
340 mm
1.5 kW
73 kg
2121252
3
F