Wilo-DrainLift BOX
Your advantages
- Easy to install due to integrated pump and non-return valve
- The large tank volume ensures a low number of switching processes
- Easy maintenance
- Stainless steel tile frame with trap
Recommended services
Design
Compact and fully-automatic sewage lifting unit for above-ground and concealed floor installation within buildings.
Application
- As a lifting unit within buildings (floor-mounted installation)
- As a pump chamber within buildings (concealed floor installation)
- For backflow resistant drainage of
- Drainage points below the backflow level
- Drainage points that cannot be drained via the natural downward slope.
Liquid
For collection and pumping of the following in domestic areas:
- Sewage not containing faeces
Sewage pumping according to 12050
The pumps meet the requirements of EN 12050-2.
Equipment/function
DrainLift BOX ...
- Submersible pump with thermal motor monitoring
- Fitted float switch
- Ready-to-plug
DrainLift BOX ... D
- Submersible pump with thermal motor monitoring
- Fitted float switch
- Ready-to-plug
DrainLift BOX ... DS
- Submersible pump with thermal motor monitoring
- Separate float switch in pump chamber
- Switchgear with mains-independent alarm and collective fault signal
Typekey
Example: | Wilo-DrainLift BOX-32/11HD DS O |
BOX | Sewage lifting unit for sewage free of faeces |
32 | Nominal diameter discharge connection of the installed pump |
11 | Max. delivery head in m |
HD | HD = Pump for aggressive fluids |
D | Lifting unit version:
|
S | Pump control:
|
O | Installation type:
|
Technical data
- Mains connection: 1~230 V, 50 Hz
- Discharge connection: 40 mm
- Inlet connection: 110 mm (DN 100)
- Ventilation connection: 110 mm (DN 100)
- Tank volume: 113 l
- Switching volume: 22 … 30 l
- Switchgear protection class (for DS version): IP54
Materials
DrainLift BOX-32 ...
- Pump chamber:
- Tank: PE
- Pipework: PE
- Non-return valve: PE
- Pump:
- Pump housing: PP-GF30
- Motor housing: 1.4301 (AISI 304)HD version: AISI 316L
- Impeller: PPE/PS-GF20
- Seal on the motor side: NBR
- Seal on the fluid side: C/SIC (BQ1PFF)
- Static seal: NBR
DrainLift BOX-40 ...
- Pump chamber:
- Tank: PE
- Pipework: PE
- Non-return valve: PE
- Pump:
- Pump housing: EN-GJL-200 (ASTM A48 Class 30)
- Motor housing: 1.4301 (AISI 304)
- Impeller: PK-GF30
- Seal on the motor side: NBR
- Seal on the fluid side: C/MgSi (BXPFF)
- Static seal: NBR
Construction
DrainLift BOX-32 ... and DrainLift BOX-32 ... D ...
Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.
Sewage pump with integrated turbulator (twister function), open multi-channel impeller and vertical threaded connection. Pump housing, strainer and impeller made of composite material. 1~ motor (jacket cooling) with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Connection cable with float switch and fitted plug (CEE 7/7).
The twister function guarantees permanent turbulence within the pump's intake area. The turbulence prevents the settling sediments from sinking and settling. This ensures a clean pump sump and reduces the build-up of odours.
The level control takes place via the float switch attached to the pump. The “pump on/off” switching level is determined by the cable length of the float switch.
DrainLift BOX-32 ... DS ...
Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.
Sewage pump with integrated turbulator (twister function), open multi-channel impeller and vertical threaded connection. Pump housing, strainer and impeller made of composite material. 1~ motor (jacket cooling) with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Connection cable with float switch and fitted plug (CEE 7/7).
The twister function guarantees permanent turbulence within the pump's intake area. The turbulence prevents the settling sediments from sinking and settling. This ensures a clean pump sump and reduces the build-up of odours.
The level control takes place via the separate float switch in the tank and a switchgear. The switchgear is preset. The “pump on” switching point is determined by the cable length of the float switch. The “pump off” switching point is defined by the set follow-up time in the switchgear. The switchgear offers the following functions:
- Collective fault signal (SSM)
- High water alarm – additional float switch available as an accessory
- Integrated buzzer, mains-independent – 9 V rechargeable battery included in the scope of delivery
DrainLift BOX-40 ... and DrainLift BOX-40 ... D ...
Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.
Sewage pump with vortex impeller and vertical threaded connection. Hydraulics housing made of grey cast iron, impeller made of plastic. Surface-cooled 1~ motor with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Detachable connection cable with float switch and fitted plug (CEE 7/7).
The level control takes place via the float switch attached to the pump. The “pump on/off” switching level is determined by the cable length of the float switch.
DrainLift BOX-40 ... DS ...
Gas-tight and watertight collection reservoir made from plastic, with deposit-free interior. Two DN 100 connections at a 180° angle to each other for the inlet as well as venting and cable routing. The discharge connection is located at a 90° angle to the other two connections. For easy maintenance of the unit, the cover serves as an inspection opening.
Sewage pump with vortex impeller and vertical threaded connection. Hydraulics housing made of grey cast iron, impeller made of plastic. Surface-cooled 1~ motor with integrated operating capacitor and self-switching thermal motor monitoring. Stainless steel motor housing. Oil-filled sealing chamber with double sealing: a rotary shaft seal is installed on the motor side, a mechanical seal on the pump side. Detachable connection cable with fitted plug (CEE 7/7).
The level control takes place via the separate float switch in the tank and a switchgear. The switchgear is preset. The “pump on” switching point is determined by the cable length of the float switch. The “pump off” switching point is defined by the set follow-up time in the switchgear. The switchgear offers the following functions:
- Collective fault signal (SSM)
- High water alarm – additional float switch available as an accessory
- Integrated buzzer, mains-independent – 9 V rechargeable battery included in the scope of delivery
Scope of delivery
DrainLift BOX ... E
- Plastic chamber with installed pipework
- Pipework with non-return valve
- Pump with float switch and plug
- Pressure hose (inside diameter: 40 mm/1.5 in; length: 7 cm/2.8 in) incl. hose clips
- O-ring to seal tank cover and as anti-syphon trap
- Concealed floor installation
- Tank cover with tile frame and floor drain
- Shell cover
- Floor-mounted installation
- Tank cover (cover plug)
- Fixation material for buoyancy safeguards
- Installation and operating instructions
DrainLift BOX ... D
- Plastic chamber with installed pipework
- Pipework with non-return valve and Y-piece
- Two pumps with float switch and plug
- Pressure hose (inside diameter: 40 mm/1.5 in; length: 7 cm/2.8 in) incl. hose clips
- O-ring to seal tank cover and as anti-syphon trap
- Concealed floor installation
- Tank cover with tile frame and floor drain
- Shell cover
- Floor-mounted installation
- Tank cover (cover plug)
- Fixation material for buoyancy safeguards
- Installation and operating instructions
DrainLift BOX ... DS
- Plastic chamber with installed pipework
- Pipework with non-return valve and Y-piece
- Two pumps with plug
- Pressure hose (inside diameter: 40 mm/1.5 in; length: 7 cm/2.8 in) incl. hose clips
- O-ring to seal tank cover and as anti-syphon trap
- Concealed floor installation
- Tank cover with tile frame and floor drain
- Shell cover
- Floor-mounted installation
- Tank cover (cover plug)
- Fixation material for buoyancy safeguards
- Switchgear with float switch and plug
- 9 V rechargeable battery
- Installation and operating instructions
Accessories
- Collar − to stop ground water from seeping into the concealed floor installation.
- Alarm switchgears − to detect leakages.
- Float switch − to detect high water levels.
- Diaphragm pump − for emergency draining.
- Stop valve