Wilo-DrainLift SANI-XL | Wilo

Wilo-DrainLift SANI-XL

The large double pump lifting unit for apartment blocks and commercial buildings.

Your advantages
Wilo-DrainLift SANI-XL

The large double pump lifting unit for apartment blocks and commercial buildings.

The Wilo-DrainLift SANI-XL large double faeces lifting unit is the perfect solution for use in large apartment blocks and commercial buildings with uncontrolled sewage intake thanks to its particularly large pump volume and the selectable continuous duty and intermittent periodic duty motor operating modes. With a free ball passage of 44 mm or 65 mm, freely selectable inlets and the optional version for particularly aggressive fluids, it can be used flexibly and is easy to install.

Maintenance is made particularly easy by the user-friendly construction.


Your advantages

  • Easy installation and transport thanks to light weight
  • High operational reliability thanks to double-pump system, a very large switching volume, thermal motor protection and mains-independent alarm
  • Corrosion-free design with engineering plastics and stainless steel guarantees high reliability
  • Freely selectable connections for maximum installation flexibility
  • Universal use thanks to several variants with two free ball passage sizes (44/65 mm), operating mode for continuous duty or intermittent periodic duty and the version for aggressive fluids
  • Transparent reservoir cover and cleaning opening in the non-return valve ensure easy maintenance
Series description
Wilo-DrainLift SANI-XL

Design

Ready for connection and fully submersible double pump lifting unit for pumping sewage containing faeces.

Application

Pumping of sewage containing faeces:

  • In cases where sewage cannot be led to the sewer system via a natural fall.
  • For the backflow resistant drainage in cases where the discharge point is below the backflow level.

Equipment/function

  • Switchgear with mains-independent alarm and collective fault signal
  • Ready-to-plug
  • Tank with inspection opening and transparent cover
  • Analogue level measurement (4 … 20 mA)
  • Non-return valve with inspection opening
  • Thermal motor monitoring with bimetallic strip

Typekey

Example: DrainLift SANI-XL.13T/4C

DrainLift

Product family

SANI

Sewage lifting unit

XL

Size

13

Max. delivery head

T

Mains connection:

  • M = 1~
  • T = 3~

4

Version motor and switchgear:

  • 1 = operating mode: S3, switchgear: Control MS-L
  • 2 = operating mode: S1, switchgear: Control MS-L
  • 3 = operating mode: S3, switchgear: Control EC-L
  • 4 = operating mode: S1, switchgear: Control EC-L

C

Version for aggressive fluids

Technical data

  • Mains connection: 3~400 V, 50 Hz
  • Operating mode: S3 10%/S1
  • Fluid temperature: 3 ... 40 °C, max. 65 °C for 5 min
  • Max. ambient temperature: 40 °C
  • Vessel volume: 358 l
  • Usable volume with regard to the positive suction head*: 148 l (250 mm*)/182 l (315 mm*)/286 l (560 mm*)
  • Pressure connection: DN 80
  • Inlet connection: DN 100/150/200
  • Ventilation connection: 75 mm
  • Switchgear degree of protection: IP54
  • Lifting unit degree of protection: IP68 (2 mWG/7 d)

Materials

  • Motor housing: 1.4404
  • Hydraulics: PP-GF30
  • Impeller: PP-GF30 or 1.4408
  • Tank: PE
  • Non-return valve: PPS

Construction

Gas- and watertight collection reservoir with collecting space that slopes at an angle and inspection opening with transparent cover. The inlets are freely configurable, level measurement is performed with an analogue output signal 4…20 mA. Pressure connection with attached non-return valve with inspection opening.

Drive via a surface-cooling or self-cooling motor with thermal motor monitoring.

Pre-installed switchgear for automatic operation:

Wilo-Control MS-L

  • Collective fault signal with potential-free contact
  • Integrated and mains-independent alarm
  • Adjustable follow-up time
  • 1.5 m connection cable with attached plug

Wilo-Control EC-L

  • Operation via display and icon-based, alphanumeric menu
  • Collective fault signal with potential-free contact
  • Individual fault signal with potential-free contact
  • ModBus interface
  • Integrated and mains-independent alarm
  • Adjustable follow-up time
  • 1.5 m connection cable with attached plug

Delivery state

  • Lifting unit with switchgear and connection cable with plug
  • Flange connector DN 80/100
  • Collar DN 100 for pressure connection
  • Collar 75 mm for ventilation connection
  • Collar DN 50 for evacuation connection
  • Inlet set with hole saw 124 mmand gasket DN 100
  • Fixation material
  • 9 V rechargeable battery
  • Operating and maintenance manual
Downloads

Installation and operating instructions

Wilo-DrainLift SANI-XL

Article Number 2552855
Edition 2020-09
Page format 209.9 x 297.0 mm
Number of pages 32
PDF (4 MB)

Wilo-DrainLift SANI-XL

Article Number 2553670
Edition 2020-09
Page format 209.9 x 297.0 mm
Number of pages 56
PDF (5 MB)

Wilo-Control MS-L

Article Number 2552612
Edition 2020-05
Page format 209.9 x 297.0 mm
Number of pages 40
PDF (3 MB)

Wilo-Control MS-L

Article Number 2552610
Edition 2020-05
Page format 209.9 x 297.0 mm
Number of pages 64
PDF (4 MB)

Wilo-Control EC-L

Article Number 2543252
Edition 2018-12
Page format 209.9 x 297.0 mm
Number of pages 56
PDF (5 MB)

General overview (Documents)

General overview 2021 International version

Edition 2020
Page format 209.9 x 297.0 mm
Number of pages 74
PDF (10 MB)

Certification booklet

Wilo-DrainLift SANI

Article Number 6088777
Edition 2020-06
Page format 209.9 x 297.0 mm
Number of pages 40
PDF (2 MB)

Certificate REACH (Documents)

REACH regulation

Edition 2021-10
Page format 209.9 x 297.0 mm
Number of pages 2