Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-SiFire Easy | Wilo
Your advantages
Wilo-SiFire Easy

Your advantages

  • Pressure-loss optimised system designed in accordance with the EN 12845 standard with electrical or diesel drive, jockey pump for maintaining system pressure
  • Flexible, modular and solid construction for safe transport and simple installation
  • Bypass volume flow for the protection of the pump with spacer coupling for simple maintenance
  • Optimum regulation and ease of use via EC-Fire control with direct display of the current operating status
  • Special baseplate for minimal vibrations, cable laid in the construction in such a way as to ensure maximum reliability and service life

Series description
Wilo-SiFire Easy

Design

Pressure-boosting systems for firefighting according to EN 12845. Consists of 1 or 2 pumps, depending on the module, with horizontal baseplate - EN 733 - with spacer coupling, electric or diesel motor and a multistage, vertical electric jockey pump.

Application

Fully automatic water supply for fire-fighting systems with sprinklers in domestic, commercial and public buildings, hotels, hospitals, shopping centres and industrial buildings.

Equipment/function

  • One or two pumps with a horizontal base frame from the series 32-200 to 150-315, with an IE-equivalent standard motor or diesel motor
  • With a diaphragm installed directly on the main pump housing to prevent overheating in the event of zero flow
  • Jockey pump of Medana CV1-L series with pressure switch and vertical pressure tank 20 l, PN 16
  • One switch cabinet per pump, fixed to a robust support structure. Model EC-Fire E for the electric motor and D for the diesel motor, both equipped with Easy Controller, plus J for the jockey pump
  • Base frame made of electro-galvanised steel with height-adjustable holder for the outlet manifold
  • Pipework made of steel; painted with epoxy resin. Manifold with flanges
  • Shutting gate with safety lock on the discharge side of each pump
  • Swing check valve on the discharge side of each pump
  • A circuit with dual pressure switch, pressure gauge, swing check valve, valve for the main pump and standby pump for automatic start
  • Concentric cone on the discharge side of the main and standby pump, for speed limitation according to the parameters specified in EN 12845
  • DN 2" connection for the supply tank of the pumps
  • Pressure measurement on the discharge side
  • Only for the model with diesel motor:
    • Vibration damping sleeve on the discharge side of the pump
    • Vibration damper under the base frame of the pump
    • Fuel tank with level sensor and sufficient volume for six hours of autonomous operation
    • Two batteries on the base frame and battery charger in the EC-Fire switchgear
  • Accessories upon request: Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Horizontal 500 l supply tank, with float valve and pressure switch for LL-alarm (water shortage)
    • Flow meter: Kit with eccentric cone on the suction side, complete with butterfly valve with hand lever or handwheel
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Vibration damping sleeve for the manifold
    • Remote control panel for transmitting level A and level B alarms
    • Density meter for battery
    • Spare parts kit for the diesel motor
    • Silencer (30 dBA) for the diesel motor
    • Hydraulic heat exchanger for the diesel motor

Typekey

Example:

Wilo-SiFire Easy 40/200-180-7.5/10.5 EDJ

SiFire

Compact pressure boosting system for fire fighting equipment

Easy

Easy handling and in accordance with standard EN 12845

40/200

Type of main pump

180

Actual impeller diameter of the main pump

7.5

Power of the electric motor [kW]

10.5

Power of the diesel motor [kW]

EDJ

Configuration

E

One electric pump

D

A diesel pump

J

A jockey pump

Technical data

  • Mains connection 3~400 V, 50 Hz (1~230 V, 50 Hz for the control panel of the diesel pump)
  • IE equivalent standard motors, diesel motor with direct injection or turbo diesel motor with air or water cooling
  • Max. ambient temperature +4 °C to +40 °C (+10 °C to +40 °C, if a diesel pump is installed)
  • Max. fluid temperature +25 °C
  • Max. operating pressure 10 or 16 bar
  • Max. inlet pressure 6 bar
  • Volume flow 10 m³/h to 750 m³/h
  • Max. delivery head 128m
  • Nominal connection diameters on the discharge side DN 65 to DN 250
  • Nominal connection diameters on the intake side DN 50 to DN 200
  • Switch cabinet protection class IP54
  • Main/standby pump with horizontal base frame in accordance with EN 733
  • With epoxy resin painted piping and hydraulic connections
  • Permissible fluids: Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Non-aggressive, clean water
    • Firefighting water

Materials

For the pump with a horizontal base frame, depending on the model

  • Impellers made of bronze CuSn10 or CuAl10Fe5Ni5 or stainless steel AISI 316/ 1.4401
  • Pump housing made of grey cast iron EN-GJL-250
  • Shaft made of stainless steel AISI420/1.4021 or AISI 431/ 1.4057
  • Neck rings made of stainless steel AISI316L/1.4409 or bronze

For the jockey pump

  • Impellers made of stainless steel AISI 304/ 1.4301
  • Pump housing made of stainless steel AISI304/1.4301
  • Shaft made of stainless steel AISI 304/ 1.4301
  • O-ring seals made of EPDM

Construction

  • Base frame: Manufactured from profiles consisting of electro-galvanised steel with brackets for the switch cabinets and the outlet manifold. Special square holes at the bottom for forklift trucks, as well as integrated hooks for lifting slings. Side profiles at the top on each side to enhance the rigidity of the system when moving and lifting.
  • Plastic cover at the rear which provides visual access to the valve position and pressure gauge.
  • Pipework: Complete pipework with flanges made of epoxy resin painted steel, suitable for the connection of all common piping materials; the dimensions of the pipework must correspond to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 or 2 pumps with horizontal base frame - EN 733 - with spacer coupling, electric or diesel motor.
  • • Back-pull-out model to ensure the internal parts of the pump are easy to access without having to move the motor or piping.
  • Valves: The main pumps are fitted with a shut-off valve and non-return valve on the discharge side, both of which are painted with epoxy resin and adapted for a flange connection.
  • Diaphragm pressure vessel: Diaphragm pressure vessel 20 l/PN16, on the discharge side of the jockey pump, with drain plug.
  • Tank: The fuel tank is made of metal painted with epoxy resin and is located behind the bracket of the switch cabinet
  • Sensors and display: 2 pressure switches, 2/16 bar per pump, on the discharge side, for activating the pump start via the EC-Fire controller and regulator. The discharge side pressure gauge (∅ 63 mm) is located in the middle of the rear panel.
  • Controller: The system is equipped as standard with a separate switchgear/control device (EC Fire) for the electric or diesel motor and a switchgear/control device for the jockey pump.

Scope of delivery

  • Factory-mounted, ready-for-installation pressure-boosting system, which has been checked for functionality and impermeability
  • Installation and operating instructions
  • Required accessories on request

Consulting guide

Inlet pressure

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum delivery head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For each main pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 350 m³/h (97 l/s) system configuration for each main pump.

Operation

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

The jockey pump is started and stopped automatically by a pressure switch. It is designed in such a way that not only individual sprinklers are supplied with fluid and pressure, but the entire system. This ensures the main pump is prevented from being started and that the system remains pressurised. If a lower pressure value is caused by the demand for water, which is not compensated by the jockey pump, the main and standby pump are started one after the other. The system starts automatically, it can be stopped manually using the switch on the front of the control panel.

Documents

Installation and operating instructions

Wilo-SiFire Easy

Article Number 4206362
Edition 1801
Number of pages 116
PDF (8 MB)

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Number of pages 451
PDF (18 MB)

Wilo-SiFire Easy

Article Number 4206363
Edition 2019-12
Number of pages 116
PDF (4 MB)
Product selection
Number of results: 468
29 … 756 m³/h
[468]
Product descriptionSystem output without standby pump QMaximum operating pressure PNGross weight, approx. mArticle number
SiFire-Easy-100/200-194-37E
366 m³/h
10 bar
1634 kg
4205119
SiFire-Easy-100/200-194-37EJ
366 m³/h
10 bar
1006 kg
4205167
SiFire-Easy-100/200-194-47,7D
366 m³/h
10 bar
1028 kg
4205215
SiFire-Easy-100/200-194-47,7DJ
366 m³/h
10 bar
1083 kg
4205263
SiFire-Easy-100/200-205-45/45EEJ
377 m³/h
10 bar
1818 kg
4205312
SiFire-Easy-100/200-205-45/47,7EDJ
377 m³/h
10 bar
2180 kg
4205360
SiFire-Easy-100/200-205-45E
377 m³/h
10 bar
1681 kg
4205120
SiFire-Easy-100/200-205-45EJ
377 m³/h
10 bar
1123 kg
4205168
SiFire-Easy-100/200-205-47,7D
377 m³/h
10 bar
1028 kg
4205216
SiFire-Easy-100/200-205-47,7DJ
377 m³/h
10 bar
1083 kg
4205264
SiFire-Easy-100/200-212-45/45EEJ
250 m³/h
16 bar
1762 kg
4242329
SiFire-Easy-100/200-212-45/47,7EDJ
250 m³/h
16 bar
2050 kg
4242379
SiFire-Easy-100/200-212-45E
250 m³/h
16 bar
1624 kg
4242041
SiFire-Easy-100/200-212-45EJ
250 m³/h
16 bar
1654 kg
4242116
SiFire-Easy-100/200-212-47,7D
250 m³/h
16 bar
1207 kg
4242191
SiFire-Easy-100/200-212-47,7DJ
250 m³/h
16 bar
1251 kg
4242266
SiFire-Easy-100/200-219-55/55EEJ
387 m³/h
10 bar
1952 kg
4205313
SiFire-Easy-100/200-219-55/66EDJ
387 m³/h
10 bar
2307 kg
4205361
SiFire-Easy-100/200-219-55E
387 m³/h
10 bar
1936 kg
4205121
SiFire-Easy-100/200-219-55EJ
387 m³/h
10 bar
1191 kg
4205169
SiFire-Easy-100/200-219-66D
387 m³/h
10 bar
1068 kg
4205217
SiFire-Easy-100/200-219-66DJ
387 m³/h
10 bar
1123 kg
4205265
SiFire-Easy-100/200-222-55/55EEJ
323 m³/h
16 bar
1790 kg
4242330
SiFire-Easy-100/200-222-55/66EDJ
323 m³/h
16 bar
2084 kg
4242380
SiFire-Easy-100/200-222-55E
323 m³/h
16 bar
1382 kg
4242042
SiFire-Easy-100/200-222-55EJ
323 m³/h
16 bar
1412 kg
4242117
SiFire-Easy-100/200-222-66D
323 m³/h
16 bar
1358 kg
4242192
SiFire-Easy-100/200-222-66DJ
323 m³/h
16 bar
1402 kg
4242267
SiFire-Easy-100/200-228-66D
321 m³/h
16 bar
1213 kg
4242193
SiFire-Easy-100/200-228-66DJ
321 m³/h
16 bar
1257 kg
4242268
SiFire-Easy-100/200-228-75E
321 m³/h
16 bar
1421 kg
4242043
SiFire-Easy-100/200-228-75EJ
321 m³/h
16 bar
1451 kg
4242118
SiFire-Easy-100/250-233-55/55EEJ
348 m³/h
10 bar
1984 kg
4205314
SiFire-Easy-100/250-233-55/66EDJ
348 m³/h
10 bar
2346 kg
4205362
SiFire-Easy-100/250-233-55E
348 m³/h
10 bar
1979 kg
4205122
SiFire-Easy-100/250-233-55EJ
348 m³/h
10 bar
1207 kg
4205170
SiFire-Easy-100/250-233-66D
348 m³/h
10 bar
1084 kg
4205218
SiFire-Easy-100/250-233-66DJ
348 m³/h
10 bar
1140 kg
4205266
SiFire-Easy-100/250-247-75E
375 m³/h
10 bar
1688 kg
4225091
SiFire-Easy-100/250-247-75EJ
375 m³/h
10 bar
1846 kg
4225110
SiFire-Easy-100/250-247-100D
375 m³/h
10 bar
1408 kg
4225129
SiFire-Easy-100/250-247-100DJ
375 m³/h
10 bar
1493 kg
4225148
SiFire-Easy-100/250-255-90E
276 m³/h
16 bar
1615 kg
4242044
SiFire-Easy-100/250-255-90EJ
276 m³/h
16 bar
1645 kg
4242119
SiFire-Easy-100/250-255-100D
276 m³/h
16 bar
1233 kg
4242194
SiFire-Easy-100/250-255-100DJ
276 m³/h
16 bar
1277 kg
4242269
SiFire-Easy-100/250-256-90E
383 m³/h
10 bar
1735 kg
4225092
SiFire-Easy-100/250-256-90EJ
383 m³/h
10 bar
1892 kg
4225111
SiFire-Easy-100/250-256-100D
383 m³/h
10 bar
1408 kg
4225130
SiFire-Easy-100/250-256-100DJ
383 m³/h
10 bar
1493 kg
4225149