Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-Initial Waste | Wilo
Your advantages
Wilo-Initial Waste

Your advantages

  • Operationally reliable due to self-switched motor protection
  • Easy operation due to fitted float switch
Series description
Wilo-Initial Waste

Design

Submersible pump for transportable wet installation in intermittent operation.

Liquid

For the pumping in domestic areas (household) of the fluids listed:

  • Sewage without faeces
  • Wastewater (with small amounts of sand and gravel)

Equipment/function

  • Integrated operating capacitor
  • Self-switching thermal motor monitoring
  • Float switch
  • Shockproof plug

Typekey

Example:

Wilo-Initial WASTE 14-9/523/AEF-10M

Initial WASTE

Submersible sewage pump

14

Max. volume flow in m³/h

9

Max. delivery head in m

5

Mains frequency:

  • 5 = 50 Hz
  • 6 = 60 Hz

23

Code for rated voltage:

  • 22 = 1~220 V
  • 23 = 1~230 V

A

Connection cable with float and plug

EF

Plug type

  • EF = type CEE 7/7
  • B = type B
  • I = type I
  • M = type M

10M

Length of connection cable

Technical data

  • Mains connection: 1~230 V, 50 Hz; 1~220 V, 50 Hz; 1~220 V, 60 Hz
  • Submerged operating mode: S1
  • Non-immersed operating mode: S3 25%
  • Protection class: IP68
  • Insulation class: F (155 °C/311 °F)
  • Fluid temperature: 3 ... 35 °C (37 ... 95 °F)

Materials

  • Hydraulics housing: PP
  • Impeller: PA6-GF30
  • Motor housing: 1.0038 (steel)
  • Sealing:
    • Hydraulics/motor: NBR
    • Static: NBR
  • Shaft end: 1.4005 (AISI 416)

Construction

Submersible pump with a vortex impeller and a vertical discharge port with threaded connection (male thread). Pump housing and impeller made of composite material. Surface-cooled single-phase AC motor (operating capacitor integrated) with self-switching thermal motor monitoring and a rotary shaft seal. Motor housing made of steel. Connection cable with a float switch and a shockproof plug.

Scope of delivery

  • Pump
  • Elbow with threaded flange (pre-mounted)
  • Installation and operating instructions
Documents

Installation and operating instructions

Wilo-Initial DRAIN & WASTE

Article Number 6097589
Edition 2025-02
Number of pages 12
Language en
PDF (7 MB)

Operating instructions (digital)

Wilo-Initial DRAIN & WASTE

Article Number 6097589
Edition 2025-02
Language bg, el, en, es, et, fr, it, lt, lv, nl, pl, pt, ro, sr, sv, tr, uk
HTML (269 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (271 KB)