DrainLift WS 40/50 Basic
Lifting unit, Pump chamber
- Pressure-tight chamber for subterranean and above ground installation
- Flexible due to freely selectable inlets
- Large tank volume
- Including pipework, level control, switchgear and pump



Design
Plastic chamber as single or double pump system. Suitable for underground installation (below ground) or building installation (above ground).Application
- As a lifting unit inside buildings (above ground).
- As a pump chamber outside buildings (below ground).
- For backflow resistant drainage of
- Drainage points below the backflow level
- Drainage points that cannot be drained via the natural downward slope
Liquid
For collection and pumping of the following fluids in commercial areas:
- Sewage containing faeces
- Sewage without faeces
- Wastewater (with small amounts of sand)
Sewage pumping according to 12050
- EN 12050-1:
- DrainLift WS50E BASIC/M3-06-523/0-EF
- DrainLift WS50E BASIC/U-06-523/0-EF
- DrainLift WS50D BASIC/M3-06-523/1-O
- DrainLift WS50D BASIC/U-06-523/1-O
- DrainLift WS40E BASIC/M3S-08-523/0-EF
- DrainLift WS40E BASIC/M3S-08-540/3-O
- DrainLift WS40E BASIC/F3S-015-540/3-O
- EN 12050-2:
- DrainLift WS40E BASIC/M3-06-523/0-EF
- DrainLift WS40E BASIC/M3-06-540/1-O
- DrainLift WS40D BASIC/M3-06-523/3-O
- DrainLift WS40D BASIC/M3-06-540/3-O
Equipment/function
- Shut-off ball valve
- Non-return valve
- Switchgear (depending on type)
- Level control device with float switch or level sensor
- Submersible pump with thermal motor monitoring
Type key
Example: | DrainLift WS40D BASIC/M3-06-523/3-O |
DrainLift | Product family |
WS | Pump chamber |
40 | Nominal diameter of the discharge port:
|
D | Chamber design:
|
BASIC | Pump chamber with pump and level control |
M3 | Pre-assembled pump:
|
06 | Value/10 = Rated power P2 of the pump in kW |
5 | Mains frequency: 5 = 50 Hz, 6 = 60 Hz |
23 | Key for rated voltage:
|
3 | Pump and switchgear version:
|
O | Connection cable version:
|
Technical data
- Tank volume: 255 l/67 US.liq.gal. (WS...E)/400 l/105 US.liq.gal. (WS...D)
- Maximum pressure in the discharge pipeline: 6 bar (87 psi)
- Discharge port: G 2/50 mm (WS 40), G 2½/63 mm (WS 50)
- Inlet connection: DN/OD 32 to DN/OD 200
- Ventilation connection: DN/OD 75
- Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
- Fluid temperature: 3 to 40 °C (37 to 104 °F), max. 65 °C (149 °F) for 5 minutes
- Ambient temperature max.: 3 to 40 °C (37 to 104 °F)
Materials
Pump chamber
- Pump chamber: PE
- Pipework: PVC
- Stopcock: PVC
- Non-return valve: PVC
Sewage pump (without macerator)
- Rexa MINI3
- Hydraulics housing: EN-GJL-200 (ASTM A48 Class 30)
- Impeller: PK-GF30
- Motor housing: 1.4301 (AISI 304)
- Seal on the pump side: C/MgSi
- Seal on the motor side: NBR
- Rexa UNI
- Hydraulics housing: PP-GF30
- Impeller: PP-GF30
- Motor housing: 1.4301 (AISI 304)
- Seal on the pump side: SiC/SiC
- Seal on the motor side: C/Cr
Sewage pump (with macerator)
- Rexa MINI3-S
- Hydraulics housing: EN-GJL-200 (ASTM A48 Class 30)
- Impeller: EN-GJL-250 (ASTM A48 Class 35/40B)
- Macerator: 1.4528/59 HRC (AISI 440B+Co)
- Motor housing: 1.4301 (AISI 304)
- Seal on the pump side: SiC/SiC
- Seal on the motor side: NBR
- Rexa FIT-S
- Hydraulics housing: EN-GJL-200 (ASTM A48 Class 30)
- Impeller: EN-GJL-250 (ASTM A48 Class 35/40B)
- Macerator: 1.4528/59 HRC (AISI 440B+Co)
- Motor housing: 1.4301 (AISI 304)
- Seal on the pump side: SiC/SiC
- Seal on the motor side: C/MgSiO
Construction
Pump chambers with submersible sewage pump without macerator
DrainLift WS40E BASIC/ ... -523/0-EF and DrainLift WS50E BASIC/ ... -523/0-EF
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber body with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upwardly domed pump chamber cover is walkable and can be loaded with max. 200 kg. For installation in buildings, the pump chamber is equipped with a floor fixation.
Pipework
- Discharge pipe with connection on the pump side
- Shut-off ball valve
- Non-return ball valve
Pump
Submersible sewage pump for single-phase AC current connection. Surface-cooled motor with thermal motor protection (self-switching) and plug.
Level control device
The level control takes place via the float switch attached to the pump. When the switch-off level is reached, the pump is immediately deactivated.
DrainLift WS40E BASIC/ ... -540/1-O
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber body with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upwardly domed pump chamber cover is walkable and can be loaded with max. 200 kg. For installation in buildings, the pump chamber is equipped with a floor fixation.
Pipework
- Discharge pipe with connection on the pump side
- Shut-off ball valve
- Non-return ball valve
Pump
Submersible sewage pump for three-phase alternating current (three-phase current connection). Surface-cooled motor with thermal motor protection and bare cable end.
Level control device
The level control device is a switchgear with a float switch. When the switch-off level is reached, the pump is deactivated after the set follow-up time.
DrainLift WS40D BASIC/ ... -523/3-O
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber body with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upwardly domed pump chamber cover is walkable and can be loaded with max. 200 kg. For installation in buildings, the pump chamber is equipped with a floor fixation.
Pipework
- Discharge pipe with connection on the pump side
- Shut-off ball valve
- Non-return ball valve
Pump
Submersible sewage pump for single-phase AC current connection. Surface-cooled motor with thermal motor protection (self-switching) and plug.
Level control device
The level control device is a switchgear with a level sensor. When the switch-off level is reached, the pump is deactivated after the set follow-up time.
DrainLift WS40D BASIC/ ... -540/3-O
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber body with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upwardly domed pump chamber cover is walkable and can be loaded with max. 200 kg. For installation in buildings, the pump chamber is equipped with a floor fixation.
Pipework
- Discharge pipe with connection on the pump side
- Shut-off ball valve
- Non-return ball valve
Pump
Submersible sewage pump for three-phase alternating current (three-phase current connection). Surface-cooled motor with thermal motor protection and bare cable end.
Level control device
The level control device is a switchgear with a level sensor. When the switch-off level is reached, the pump is deactivated after the set follow-up time.
DrainLift WS50D BASIC/ ... -523/1-O
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber body with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upwardly domed pump chamber cover is walkable and can be loaded with max. 200 kg. For installation in buildings, the pump chamber is equipped with a floor fixation.
Pipework
- Discharge pipe with connection on the pump side
- Shut-off ball valve
- Non-return ball valve
Pump
Submersible sewage pump for single-phase AC current connection. Surface-cooled motor with thermal motor protection (self-switching) and bare cable end.
Level control device
The level control device is a switchgear with a float switch. When the switch-off level is reached, the pump is deactivated after the set follow-up time.
Pump chambers with submersible sewage pump with macerator
DrainLift WS40E BASIC/ ... -523/0-EF
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber body with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upwardly domed pump chamber cover is walkable and can be loaded with max. 200 kg. For installation in buildings, the pump chamber is equipped with a floor fixation.
Pipework
- Discharge pipe with connection on the pump side
- Shut-off ball valve
- Non-return ball valve
Pump
Submersible sewage pump with macerator for connection to single-phase current. Surface-cooled motor with thermal motor protection (self-switching), capacitor box (with starting and operating capacitor) and plug.
Level control device
The level control takes place via the float switch attached to the pump. When the switch-off level is reached, the pump is immediately deactivated.
DrainLift WS40E BASIC/ ... -540/3-O
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber body with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upwardly domed pump chamber cover is walkable and can be loaded with max. 200 kg. For installation in buildings, the pump chamber is equipped with a floor fixation.
Pipework
- Discharge pipe with connection on the pump side
- Shut-off ball valve
- Non-return ball valve
Pump
Submersible sewage pump with macerator for three-phase current connection (three-phase connection). Surface-cooled motor with thermal motor protection and bare cable end.
Level control device
The level control device is a switchgear with a level sensor and additional float switch (as dry-running protection or high water alarm). When the switch-off level is reached, the pump is deactivated after the set follow-up time.
Scope of delivery
Versions with sewage pumps without macerator
DrainLift WS40E BASIC/ ... /0-EF and DrainLift WS50E BASIC/ ... /0-EF
- Plastic chamber with installed pipework, pump and level control
- Pipework with shut-off ball valve and non-return valve
- Pump with float switch and plug
- Chamber cover with gasket
- DN/OD 50 connection kit for drain connection
- Inlet kit with hole saw (124 mm /5 in) and seal DN/OD 110
- Floor mounting
- Installation and operating instructions
DrainLift WS40D BASIC/ ... /3-O
- Plastic chamber with installed pipework, pump and level control
- Pipework with shut-off ball valve and non-return valve
- Pump
- Switchgear
- Level sensor
- Chamber cover with gasket
- DN/OD 50 connection kit for drain connection
- Inlet kit with hole saw (124 mm /5 in) and seal DN/OD 110
- Floor mounting
- Installation and operating instructions
DrainLift WS40E BASIC/ ... /1-O and DrainLift WS50D BASIC/ ... /1-O
- Plastic chamber with installed pipework, pump and level control
- Pipework with shut-off ball valve and non-return valve
- Pump
- Switchgear
- Float switch
- Chamber cover with gasket
- DN/OD 50 connection kit for drain connection
- Inlet kit with hole saw (124 mm /5 in) and seal DN/OD 110
- Floor mounting
- Installation and operating instructions
Versions with sewage pumps with macerator
DrainLift WS40E BASIC/ ... /0-EF
- Plastic chamber with installed pipework, pump and level control
- Pipework with shut-off ball valve and non-return valve
- Pump with float switch and plug
- Float switch
- Chamber cover with gasket
- DN/OD 50 connection kit for drain connection
- Inlet kit with hole saw (124 mm /5 in) and seal DN/OD 110
- Floor mounting
- Installation and operating instructions
DrainLift WS40E BASIC/ ... /3-O
- Plastic chamber with installed pipework, pump and level control
- Pipework with shut-off ball valve and non-return valve
- Pump
- Switchgear
- Level sensor
- Float switch
- Chamber cover with gasket
- DN/OD 50 connection kit for drain connection
- Inlet kit with hole saw (124 mm /5 in) and seal DN/OD 110
- Floor mounting
- Installation and operating instructions
Accessories
- Pump chamber extension
- Clamp bolting
- Diaphragm hand pump
- Alarm switchgear
- Float switch
- Level sensor
- Inlet set (gasket and hole saw)
- Horn
- Flash light