CronoTwin-DL-E 80/160-11/2-R1
Data sheet
Materials
-
Pump housing5.1301, EN-GJL-250
-
Impeller5.1300, EN-GJL-200
-
Lantern
-
Shaft1.4122, X39CrMo17-1
Operating data
-
Min. fluid temperature T-20 °C
-
Max. fluid temperature T140 °C
-
Maximum operating pressure p16 bar
-
Max. ambient temperature T40 °C
-
Minimum efficiency index (MEI)0.4
Motor data
-
Mains connection3~440 V, 50 Hz
-
Motor efficiency classIE4
-
Emitted interferenceEN 61800-3
-
Interference resistanceEN 61800-3
-
Rated power P211.00 kW
-
Rated current IN18.50 A
-
Rated speed n2900 rpm
-
Max. speed nmax2900 rpm
-
Protection class motorIP55
Installation dimensions
-
Port-to-port length L0440 mm
-
Pipe connection on the suction sideDN 80
-
Pipe connection on the pressure sideDN 80
Information for order placements
-
Net weight, approx. m386 kg
-
BrandWilo
-
Product descriptionCronoTwin-DL-E 80/160-11/2-R1
-
Article number2153882
Dimensions and dimensions drawings
CronoTwin-DL-E 80/160-11/2-R1


Pump curves
CronoTwin-DL-E 80/160-11/2, 2-pole - individual operation

CronoTwin-DL-E 80/160-11/2, 2-pole - parallel operation



Wiring diagram
IL-E

L1, L2, L3: | Mains connection: 3~440 V ±10%, 50/60 Hz; 3~400 V ±10%, 50/60 Hz; 3~380 V -5%/+10%, 50/60 Hz |
PE: | Protective conductor connection |
DDG: | Connection for differential pressure sensor |
In1 (1): | Actual value input 0-10 V/0-20 mA; 2-10 V/4-20 mA |
GND (2): | Ground connection for In1 and In2 |
+ 24 V (3): | DC voltage output for an external consumer/sensor. Max load 60 mA |
In2: | Setpoint input 0-10 V/0-20 mA; 2-10 V/4-20 mA |
MP: | Multi-pump, interface for dual pump management |
Ext. off: | Control input “Overriding Off”The pump can be switched on or off via an external, potential-free contact (24 V DC/10 mA). |
SBM:* | Potential-free collective run signal (changeover contact according to VDI 3814) |
SSM:* | Potential-free collective fault signal (changeover contact according to VDI 3814) |
aux: | External pump cycling (only with dual pump operation). Pump cycling can be performed using an external, potential-free contact (24 VDC/10 mA) |
DIP switch: | 1: Switchover between operation (O) and service mode (S)2: Activate/deactivate the menu for access disable |
Optional: | IF-Modules for connection to the building automation |
* Load capacity of contacts for SBM and SSM: min.: 12 V DC/10 mA max.: 250 V AC/1 A |

Ordering information
Information for order placements
-
BrandWilo
-
Product descriptionCronoTwin-DL-E 80/160-11/2-R1
-
EAN number4048482554051
-
Article number2153882
-
Gross weight, approx. m425.0 kg
-
Net weight, approx. m386 kg
-
Overall length L887.0 mm
-
Height without packaging H636 mm
-
ColourGreen
-
Packaging propertyTransport packaging
-
Packaging typeOne-way pallet
-
Number per layer1
-
Width without packaging L1232.0 mm
-
Minimum order quantity1
-
Pieces per pallet1
Tender text
Glanded twin-head pump with in-line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things.
Design:
- Single-stage low-pressure centrifugal pump
- Spiral housing in in-line design (suction and pressure ports with the same flanges in one line), flanges PN 16 – drilled acc. to EN 1092-2
- Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor)
- Pump housing and motor flange with cataphoretic coating as standard
- Mechanical seal for water feed up to T=140 °C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 °C
- Special mechanical seals for water-glycol mixtures deviating from the 20–40% glycol by volume and a fluid temperature of ≤ 40 °C or fluids other than water (additional charge).
Accessories:
- Mounting brackets for fixing to the foundation
- IR-Monitor
- IF module PLR
- IF module LON
- IF module Modbus
- IF module BACnet
- IF module CAN
- Control systems VR-HVAC/CCe-HVAC/SCe-HVAC
- Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1
Standard equipment:
- One-button manual operation level for:
- Pump On/Off
- Setpoint and speed adjustment
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
Additional functions:
- Interfaces: Control input "Overriding Off", "External pump cycling", analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR Stick/IR-Monitor, plug-in position for Wilo IF-Module for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
- Three-phase AC motor with frequency converter
- Integrated dual pump management
- Adjustable time interval for pump cycling
- Integrated full motor protection
- Different operating modes for heating mode (HV) or air-conditioning mode (AC)
- Access disable
- Different operation levels: Standard / Service
Materials
-
Pump housing5.1301, EN-GJL-250
-
Impeller5.1300, EN-GJL-200
-
Lantern
-
Shaft1.4122, X39CrMo17-1
Operating data
-
Fluid mediaWater
-
Min. fluid temperature T-20 °C
-
Max. fluid temperature T140 °C
-
Maximum operating pressure p16 bar
-
Max. ambient temperature T40 °C
-
Minimum efficiency index (MEI)0.4
Motor data
-
Emitted interferenceEN 61800-3
-
Interference resistanceEN 61800-3
-
Mains connection3~440 V, 50 Hz
-
Rated power P211000 W
-
Max. speed nmax2900 rpm
-
Rated current IN18.50 A
-
Protection class motorIP55
-
Insulation classF
-
Integrated full motor protectionyes
Installation dimensions
-
Pipe connection on the suction sideDN 80
-
Pipe connection on the pressure sideDN 80
Information for order placements
-
Net weight, approx. m386 kg
-
BrandWilo
-
Product descriptionCronoTwin-DL-E 80/160-11/2-R1
-
Article number2153882
Downloads

Wilo-IL-E/DL-E/BL-E
Article Number | 2112769-72, 2122801 |
Edition | 1512 |
Version number | 01 |
Page format | A4 |
Number of pages | 1 |
PDF (144 MB)
Download
Wilo-IL-E/DL-E/BL-E
Article Number | 2112769-72, 2122801 |
Edition | 1512 |
Version number | 01 |
Page format | A4 |
Number of pages | 72 |
PDF (9 MB)
Download
Wilo-CronoLine-IL-E/DL-E/BL-E
Article Number | 2160196 |
Edition | 2017-12 |
Version number | 03 |
Page format | 209.9 x 297.0 mm |
Number of pages | 261 |
PDF (25 MB)
Download
REACH Regulation
Edition | 2018-10 |
Page format | 209.9 x 296.7 mm |
Number of pages | 4 |
PDF (581 kB)
Download