Wilo-HiDrainlift 3

Series description

Special features/product advantages

  • Very compact construction for installation in a wet area or under the shower tray (HiDrainlift 3-24)
  • Low-noise operation and installed active carbon filter for high user comfort
  • Reliable capacity and low electricity consumption for efficient wastewater disposal
  • Simple installation with flexible connection options
  • Systems ready for connection (HiDrainlift 3-35 and HiDrainlift 3-37)

Design type

Small sewage lifting unit for floor-mounted installation

Application

Pumping of pre-cleaned sewage without faeces (according to DIN EN 12050-2) that cannot be piped to the sewer system through the use of natural falls.

Equipment/function

  • Ready-to-plug
  • Thermal motor protection
  • Level checking via a pneumatic pressure transducer
  • Integrated non-return valve
  • Fixation material
  • Active carbon filter

Scope of delivery

  • Ready for connection wastewater lifting unit with macerator, active carbon filter and integrated non-return valves
  • Installation and operating instructions
  • Connection set for inlet and pressure pipes

Type key

Example:

HiDrainlift 3-35

HiDrainlift

Product family:Wastewater lifting unit

3

Product level

3 = Standard

3

Number of inlet connections

5

Rated delivery head in m

Technical data

  • Mains connection 1~230 V, 50 Hz
  • Mains connection cable 1.5 m, with shock-proof plug
  • Fluid temperature max. 35 °C (up to 60/ 75 °C in short-time duty for 5 minutes, depending on the model)
  • Pressure connection DN 32
  • Inlet connection DN 40
  • Protection class IP 44
  • Gross tank volume 3.9 l / 16 l / 15.5 l
  • Switching volume 1.7 l / 2 l / 2 l

Materials

  • Pump housing: PPGF30
  • Motor housing: PPGF30
  • Gasket: EPDM
  • Tank material: PP

Description/construction

Ready-for-connection, automatically-switching wastewater lifting unit with built-in non-return valve and 2-3 inlet connecting pieces (depending on model). Odour-free exhaust ventilation into the installation room is implemented by means of an integrated active carbon filter.

Duty chart

HiDrainLift

Downloads

General overview 2018 International version

Article Number 2200591
Edition 2018
Version number 1
Page format 209.9 x 297.0 mm
Number of pages 72

PDF (11 MB)

Download

Product

PDF: Wilo-HiDrainlift 3

Configure

Page selection

Format selection

Optional information

You can enter any personal information that you want to be displayed in the header.