SiBoost Smart 2MVISE803 | Wilo

SiBoost Smart 2MVISE803

Technical data
Tender text

Compact pressure-boosting system according to DIN 1988 and DIN EN 806, for direct or indirect connection. Consisting of non self-priming, switched in parallel, vertically-mounted stainless steel high-pressure centrifugal pumps in a glandless version, for which each pump is fitted with a frequency converter. Ready for connection with stainless steel pipework, mounted on a base frame, including control device with all necessary measurement and adjustment equipment.

For fully automatic water supply and pressure boosting in residential, commercial and administrative buildings, hotels, hospitals, department stores and for industrial systems.

For pumping drinking water, process water, cooling water, firefighting water (apart from fire-extinguishing systems in accordance with DIN 14462 and with the approval of the local fire protection authorities) or other types of industrial water that do not attack the materials either chemically or mechanically and do not contain abrasive or long-fibre constituents.

Special features/product advantages

  • Optimum pump load adjustment due to pressure-variable (pv) control mode and parallel synchronous speed control for higher energy savings
  • Up to 20 dB[A] quieter operation than conventional systems with comparable hydraulic output
  • Disproportionately large frequency converter control range from 20 Hz to a maximum of 50 Hz
  • Maintenance-free pump design without mechanical seals
  • High reliability thanks to various protective features including overload protection, dry-running protection and automatic deactivation
  • Easy setting and operation with the SCe switchgear thanks to LCD display and green adjustment button
  • Drinking water approvals for all components that come in contact with the fluid
  • Ready for integration into building automation with the SCe switchgear via standard Modbus RTU

Equipment/function

2 – 4 pumps per system of the MVISE series with glandless motors speed controlled via integrated frequency converters on each pump.

SCe switchgear ensures automatic control of the complete pressure-boosting system.

Complete assembly mounted on galvanised steel, height-adjustable base frame.

All components in contact with fluid are corrosion- resistant.

On pressure side:

  • Shut-off valve at each pump
  • Non-return valve at each pump
  • Diaphragm pressure vessel 8 l, PN 16
  • Pressure sensor 4...20 mA
  • Pressure gauge

On suction side:

  • Shut-off valve at each pump
  • Pressure sensor 4...20 mA
  • Pressure gauge

Smart-Controller (SCe) in a sheet metal enclosure, protection class IP54, consisting of an internal control voltage supply unit, microprocessor with Soft PLC, analogue and digital inputs and outputs, for control of electronic pumps with frequency converters.

A working area of 1 m around the system is recommended in order to facilitate the maintenance process.

Operation/display

  • LC display (backlit) for display of the operating data, controller parameters, operating statuses of the pumps, error messages and history memory
  • Menu navigation with symbols and menu numbers
  • LEDs for display of system status (operation/fault)
  • Factory-preset parameters for easy commissioning/start-up
  • Setting of operating parameters and acknowledgement of fault messages using Green Button Technology
  • Lockable main switch
  • Operation with/without standby pump selectable by customer service
  • Elapsed time indicator for each pump and for entire system
  • Switching cycle counter for each pump and for entire system
  • Fault memory for the last 16 faults

Control

  • Fully automatic control for 1 – 4 frequency-controlled pumps by means of setpoint/actual value comparison
  • Setpoint changeover: Second setpoint can be activated by contact
  • External remote setpoint adjustment by 4…20 mA signal
  • Automatic, load-sensitive cut-in of 1 to n peak-load pump(s) depending on the control variable “pressure constant” (p-c) or “pressure variable” (p-v)
  • 2 parameter sets selectable, easy menu (setpoint & control mode) or expert menu (operation and control parameters)
  • Operating mode of the pumps freely selectable (manual, off, automatic)
  • Automatic, configurable pump cycling
  • Standard setting: Impulse - The base-load pump is cycled at each new demand, regardless of operating hours
  • Alternative: Pump cycling dependent on operating hours, cycling of the base-load pump after the specified operating hours
  • Automatic, configurable pump test run (pump kick)
    • Can be activated/deactivated
    • Time between two pump test runs is freely programmable
  • Disabling times can be programmed as desired
  • Speed can be adjusted as desired

Monitoring

  • Actual value of the system is output via a 0 – 10 volt analogue signal for external measurement/display applications, 10 volt depending on the sensor range value
  • 4 – 20 mA sensor signal (conductivity test of the sensor cable) for control variable actual value
  • The pump mains power feed is protected via the circuit breaker
  • Automatic switchover to standby pump in the event of an operating pump fault
  • Monitoring of maximum and minimum system values with adjustable time delays and limits
  • Zero-flow test for switching off the system when no water is being drawn off (adjustable parameters)
  • Pipe filling function for filling empty pipes (initial filling of the consumer network)
  • Protection against low water level through standard 4..20 mA pressure sensor on the suction side
  • Protection against low water level via switching contact e.g. for float switch
  • Automatic shutdown of pumps if fault occurs or operation at preset emergency operation speed

Interfaces

  • Potential-free contacts for SBM/SSM collective operation and collective fault signals
  • Logic reversal can be applied to SBM and SSM
  • Contacts for external on/off, low water and second setpoint
  • External on/off via contact for deactivation of the system's automatic mode

Optional accessories (factory installation or retrofitting after technical checks)

  • Individual operation and fault signal, low-water signal
  • Signal converter for 0/2 – 10 V to 0/4 – 20 mA
  • GSM communication module (SC)
  • Internet-based WiloCare remote maintenance

Recommended accessories (to be ordered separately)

  • Flexible connection pipes or compensators
  • Threaded caps for systems with threaded joint tubing

Bus systems (optional)

  • LON-Bus, Modbus TCP, BACnet MSTP, BACnet IP

Standards followed

  • Specifications for drinking water installations (TRWI) DIN 1988 (EN 806)
  • Diaphragm pressure vessel/diaphragm expansion tank DIN 4807
  • Electronic equipment for use in power installations, EN 50178
  • Electrical Equipment of Machines EN 60204-1
  • Safety of household and similar electrical devices EN 60335-1
  • Low-voltage switchgear and controlgear assemblies EN 60439-1/61439-1
  • EMC – Immunity for industrial environments EN 61000-6-2
  • EMC – Emission standard for residential, commercial and light-industrial environments (EN 61000-6-3)
Operating data
Fluid media
Water
Number of pumps
2
Fluid temperature T
3 °C
Ambient temperature T
5 °C
Maximum operating pressure PN
16 bar
Maximum inlet pressure p inl
10 bar
Motor data
Mains connection
3~400 V, 50/60 Hz
Rated power P2
1.1 kW
Rated current IN
4.2 A
Rated speed n
2900 1/min
Insulation class
F
Protection class motor
IP44
Protection class switchgear
IP54
Materials
Pump housing
Stainless steel
Impeller
Stainless steel
Shaft
Stainless steel
Gasket material
EPDM
Pipework material
Stainless steel
Installation dimensions
Pipe connection on the suction side DNs
R 2½
Pipe connection on the pressure side DNd
R 2½
Information for order placements
Brand
Wilo
Product description
SiBoost Smart 2MVISE803
Net weight, approx. m
117 kg
Article number
2550748
Downloads

Installation and operating instructions

Wilo-SiBoost Smart ...

Article Number 2535457
Edition 1808
Page format 209.9 x 297.0 mm
Number of pages 1343
PDF (37 MB)

Wilo-Control SC-Booster (SC, SC-FC, SCe)

Article Number 2535460
Edition 1809
Page format 209.9 x 297.0 mm
Number of pages 1795
PDF (44 MB)

Certification booklet

Wilo-SiBoost Smart ...

Article Number 2550649
Edition 1905
Page format 209.9 x 297.0 mm
Number of pages 16
PDF (6 MB)

Wilo-Control SC-Booster (SC, SC-FC, SCe)

Article Number 2550530
Edition 1811
Page format 209.9 x 297.0 mm
Number of pages 8
PDF (2 MB)

Certificate REACH (Documents)

REACH regulation

Edition 2020-08
Page format 209.9 x 297.0 mm
Number of pages 2
PDF (158 KB)