Wilo-SiFire EN | Wilo
Your advantages
Wilo-SiFire EN

Your advantages

  • Pressure-loss optimised system designed in accordance with the EN 12845 Standard with electrical or diesel drive, jockey pump for maintaining system pressure
  • Flexible, modular and solid construction for safe transport and simple installation
  • Bypass volume flow for the protection of the pump with spacer coupling for simple maintenance
  • High-quality SC-Fire control prepared for BACnet and Modbus building management system integration
  • Special baseplate for minimal vibrations, cable laid in the construction in such a way as to ensure maximum reliability and service life

Series description
SiFire EN

Design

Pressure-boosting systems for firefighting according to EN 12845. Consists of 1 or 2 pumps, depending on the module, with horizontal baseplate - EN 733 - with spacer coupling, electric or diesel motor and a multistage, vertical electric jockey pump.

Application

Fully automatic water supply of fire-fighting systems with a sprinkler system in residential, commercial, public and industrial buildings, as well as hotels, hospitals and department stores.

Equipment/function

  • One or two pumps with a horizontal base frame from the series 32-200 to 150-315, with an IE-equivalent standard motor or diesel motor
  • With a diaphragm installed directly on the main pump housing to prevent overheating in the event of zero flow
  • Jockey pump of Medana CV1-L series with pressure switch and vertical pressure tank 20 l, PN 16
  • One switch cabinet per pump, fixed to a robust support structure. SC Fire model: E for the electric motor and D for the diesel motor, both equipped with Smart Controller, plus J for the jockey pump
  • Base frame made of electro-galvanised steel with height-adjustable holder for the outlet manifold
  • Pipework made of steel; painted with epoxy resin. Manifold with flanges
  • Shutting gate with safety lock on the discharge side of each pump
  • Swing check valve on the discharge side of each pump
  • A circuit with dual pressure switch, pressure gauge, swing check valve, valve for the main pump and standby pump for automatic start
  • Concentric cone on the discharge side of the main and standby pump, for speed limitation according to the parameters specified in EN 12845
  • DN 2" connection for the supply tank of the pumps
  • Pressure measurement on the discharge side
  • Only for the model with diesel motor:
    • Vibration damping sleeve on the discharge side of the pump
    • Vibration damper under the base frame of the pump
    • Fuel tank with level sensor and sufficient volume for six hours of autonomous operation
    • 2 or 4 batteries on the base frame and battery charger at the SC Fire switch cabinet
  • Accessories upon request: Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Horizontal 500 l supply tank, with float valve and pressure switch for LL-alarm (water shortage)
    • Flow meter: Kit with eccentric cone on the suction side, complete with butterfly valve with hand lever or handwheel
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Vibration damping sleeve for the manifold
    • Remote control panel for transmitting level A and level B alarms
    • Density meter for battery
    • Spare parts kit for the diesel motor
    • Silencer (30 dBA) for the diesel motor
    • Hydraulic heat exchanger for the diesel motor

Typekey

Example:

Wilo-SiFire EN 40/200-180-7.5/10.5/0.55 EDJ

SiFire

Compact pressure boosting system for fire fighting equipment

EN

in acc. with EN 12845

40/200

Type of main pump

180

Actual impeller diameter of the main pump

7.5

Power of the electric motor [kW]

10.5

Power of the diesel motor [kW]

00:55

Power of the motor for the jockey pump [kW]

EDJ

Configuration

E

An electric pump

D

A diesel pump

J

A jockey pump

Technical data

  • Mains connection 3~400 V, 50 Hz (1~230 V, 50 Hz for the control panel of the diesel pump)
  • IE-equivalent standard motors, diesel motor with direct injection or turbo diesel motor with air or water cooling
  • Max. ambient temperature +4°C to +40°C (+10°C to +40°C, if a diesel pump is installed)
  • Max. fluid temperature +40°C
  • Max. operating pressure 10 or 16 bar
  • Max. inlet pressure 6 bar
  • Volume flow 10 m³/h to 750 m³/h
  • Max. delivery head 128 m
  • Nominal connection diameters on the pressure side DN 65 to DN 250
  • Nominal connection diameters on the intake side DN 50 to DN 200
  • Switch cabinet protection class IP54
  • Main/standby pump with horizontal base plate in accordance with EN 733
  • With epoxy resin painted piping and hydraulic connections
  • Permitted fluids:Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Non-aggressive, clean water
    • Fire water

Materials

For the pump with a horizontal base frame, depending on the model

  • Impellers made of bronze CuSn10 or CuAl10Fe5Ni5 or stainless steel AISI 316/ 1.4401
  • Pump housing made of grey cast iron EN-GJL-250
  • Shaft made of stainless steel AISI420/1.4021 or AISI 431/ 1.4057
  • Neck rings made of stainless steel AISI316L/1.4409 or bronze

For the jockey pump

  • Impellers made of stainless steel AISI 304/ 1.4301
  • Pump housing made of stainless steel AISI304/1.4301
  • Shaft made of stainless steel AISI 304/ 1.4301
  • O-ring seals made of EPDM

Construction

  • Base frame: Manufactured from profiles consisting of electro-galvanised steel with brackets for the switch cabinets and the outlet manifold. Special square holes at the bottom for forklift trucks, as well as integrated hooks for lifting slings. Side profiles at the top on each side to enhance the rigidity of the system when moving and lifting.
  • Plastic cover at the rear which provides visual access to the valve position and pressure gauge.
  • Pipework: Complete pipework with flanges made of epoxy resin painted steel, suitable for the connection of all common piping materials; the dimensions of the pipework must correspond to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 or 2 pumps with horizontal base frame - EN 733 - with spacer coupling, electric or diesel motor.
  • • Back-pull-out model to ensure the internal parts of the pump are easy to access without having to move the motor or piping.
  • Valves: The main pumps are fitted with a shut-off valve and non-return valve on the discharge side, both of which are painted with epoxy resin and adapted for a flange connection.
  • Diaphragm pressure vessel: Diaphragm pressure vessel 20 l/PN16, on the discharge side of the jockey pump, with drain plug.
  • Tank: The fuel tank is made of metal painted with epoxy resin and is located behind the bracket of the switch cabinet
  • Sensors and display: 2 pressure switches, 2/16 bar per pump, on the discharge side, for activating the pump start via the SCFire controller and regulator. The discharge side pressure gauge (∅ 63 mm) is located in the middle of the rear panel.
  • Controller: The system is equipped as standard with a separate switchgear/control device (SC Fire) for the electric or diesel motor and a switchgear/control device for the jockey pump.

Scope of delivery

  • Factory-mounted, ready-for-installation pressure boosting system, which has been checked for functionality and impermeability
  • Installation and operating instructions
  • Required accessories on request

Consulting guide

Inlet pressure

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum delivery head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For each main pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 750 m³/h (208 l/s) system configuration for each main pump.

Operation

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

The jockey pump is started and stopped automatically by a pressure switch. It is designed in such a way that not only individual sprinklers are supplied with fluid and pressure, but the entire system. This ensures the main pump is prevented from being started and that the system remains pressurised. If a lower pressure value is caused by the demand for water, which is not compensated by the jockey pump, the main and standby pump are started one after the other. The system starts automatically, it can be stopped manually using the switch on the front of the control panel.

Documents

Installation and operating instructions

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 13
Language en
PDF (934 KB)

Wilo-Control SC-Fire Diesel

Article Number 2541367
Edition 1510
Number of pages 34
Language en
PDF (1 MB)

Wilo-Control SC-Fire Electric

Article Number 2539954, 2541365, 2541366
Edition 1510
Number of pages 32
Language en
PDF (2 MB)

Wilo-Control SC-Fire Jockey

Number of pages 10
Language en
PDF (727 KB)

Wilo-SiFire EN

Article Number 4188030
Edition 2019-12
Number of pages 108
Language de, en, fr, nl
PDF (9 MB)

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 148
Language en, mk, no, sr, uk
PDF (6 MB)

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 13
Language en
PDF (1 MB)

Wilo-Control SC-Fire Electric

Article Number 2539954, 2541365, 2541366
Edition 1510
Number of pages 31
Language en
PDF (1 MB)

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Number of pages 451
Language ar, bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, lt, lv, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk
PDF (18 MB)
Product selection
Number of results: 433
29 … 756 m³/h
[433]
Product descriptionSystem output without standby pump QMaximum operating pressure PNGross weight, approx. mArticle number
SiFire-EN-50/200-218-22/22EEJ
86 m³/h
16 bar
938 kg
4241706
SiFire-EN-50/200-218-22/26,5EDJ
86 m³/h
16 bar
1026 kg
4241756
SiFire-EN-50/200-218-22E
86 m³/h
16 bar
506 kg
4241406
SiFire-EN-50/200-218-22EJ
86 m³/h
16 bar
550 kg
4241481
SiFire-EN-50/200-218-26,5D
86 m³/h
16 bar
546 kg
4241556
SiFire-EN-50/200-218-26,5DJ
86 m³/h
16 bar
675 kg
4241631
SiFire-EN-50/250-220-17,7D
83 m³/h
16 bar
593 kg
4241557
SiFire-EN-50/250-220-17,7DJ
83 m³/h
16 bar
722 kg
4241632
SiFire-EN-50/250-220-18,5/17,7EDJ
83 m³/h
16 bar
1038 kg
4241757
SiFire-EN-50/250-220-18,5/18,5EEJ
83 m³/h
16 bar
962 kg
4241707
SiFire-EN-50/250-220-18,5E
83 m³/h
16 bar
512 kg
4241407
SiFire-EN-50/250-220-18,5EJ
83 m³/h
16 bar
556 kg
4241482
SiFire-EN-50/250-240-22/22EEJ
79 m³/h
16 bar
962 kg
4241708
SiFire-EN-50/250-240-22/26,5EDJ
79 m³/h
16 bar
1093 kg
4241758
SiFire-EN-50/250-240-22E
79 m³/h
16 bar
512 kg
4241408
SiFire-EN-50/250-240-22EJ
79 m³/h
16 bar
556 kg
4241483
SiFire-EN-50/250-240-26,5D
79 m³/h
16 bar
593 kg
4241558
SiFire-EN-50/250-240-26,5DJ
79 m³/h
16 bar
722 kg
4241633
SiFire-EN-50/250-242-26,5D
81 m³/h
16 bar
648 kg
4241559
SiFire-EN-50/250-242-26,5DJ
81 m³/h
16 bar
777 kg
4241634
SiFire-EN-50/250-242-30/26,5EDJ
81 m³/h
16 bar
1133 kg
4241759
SiFire-EN-50/250-242-30/30EEJ
81 m³/h
16 bar
1042 kg
4241709
SiFire-EN-50/250-242-30E
81 m³/h
16 bar
520 kg
4241409
SiFire-EN-50/250-242-30EJ
81 m³/h
16 bar
564 kg
4241484
SiFire-EN-50/250-249-30/30EEJ
83 m³/h
16 bar
1056 kg
4241710
SiFire-EN-50/250-249-30/31,5EDJ
83 m³/h
16 bar
1147 kg
4241760
SiFire-EN-50/250-249-30E
83 m³/h
16 bar
520 kg
4241410
SiFire-EN-50/250-249-30EJ
83 m³/h
16 bar
564 kg
4241485
SiFire-EN-50/250-249-31,5D
83 m³/h
16 bar
648 kg
4241560
SiFire-EN-50/250-249-31,5DJ
83 m³/h
16 bar
777 kg
4241635
SiFire-EN-50/250-258-37/37EDJ
85 m³/h
16 bar
1329 kg
4241761
SiFire-EN-50/250-258-37/37EEJ
85 m³/h
16 bar
1280 kg
4241711
SiFire-EN-50/250-258-37D
85 m³/h
16 bar
655 kg
4241561
SiFire-EN-50/250-258-37DJ
85 m³/h
16 bar
784 kg
4241636
SiFire-EN-50/250-258-37E
85 m³/h
16 bar
742 kg
4241411
SiFire-EN-50/250-258-37EJ
85 m³/h
16 bar
786 kg
4241486
SiFire-EN-65/200-178-15/15EEJ
137 m³/h
16 bar
1280 kg
4241712
SiFire-EN-65/200-178-15/17,7EDJ
137 m³/h
16 bar
1359 kg
4241762
SiFire-EN-65/200-178-15E
137 m³/h
16 bar
532 kg
4241412
SiFire-EN-65/200-178-15EJ
137 m³/h
16 bar
576 kg
4241487
SiFire-EN-65/200-178-17,7D
137 m³/h
16 bar
655 kg
4241562
SiFire-EN-65/200-178-17,7DJ
137 m³/h
16 bar
784 kg
4241637
SiFire-EN-65/200-185-17,7D
125 m³/h
16 bar
785 kg
4241563
SiFire-EN-65/200-185-17,7DJ
125 m³/h
16 bar
914 kg
4241638
SiFire-EN-65/200-185-18,5/17,7EDJ
125 m³/h
16 bar
1050 kg
4241763
SiFire-EN-65/200-185-18,5/18,5EEJ
125 m³/h
16 bar
974 kg
4241713
SiFire-EN-65/200-185-18,5E
125 m³/h
16 bar
572 kg
4241413
SiFire-EN-65/200-185-18,5EJ
125 m³/h
16 bar
616 kg
4241488
SiFire-EN-65/200-195-22/22EEJ
128 m³/h
16 bar
1057 kg
4241714
SiFire-EN-65/200-195-22/26,5EDJ
128 m³/h
16 bar
1148 kg
4241764