Search
Contact
E-mail
Catalogue creation
My favorites
Wilo-SiFire FIRST | Wilo

Wilo-SiFire FIRST

A modular design for a wide field of applications.

Your advantages
Wilo-SiFire FIRST D

A modular design for a wide field of applications.

The Wilo-SiFire FIRST is a flexible modular norm pump system in accordance with EN 12845. It could be equipped with electric or diesel motor and jockey pump for a wide field of applications. The compact system is fixed on an universal baseplate which makes the transport, installation and maintenance very easy. The robust design enables a long lifetime.

Recommended services


Your advantages

  • Modular norm pump system with electric or diesel motor for a wide field of applications and high flexibility in designing
  • Long lifetime thanks to robust design
  • Easy transport, installation and maintenance thanks to an universal base plate
  • Intuitive handling on specific firefighting controller
  • Equipment and pipes calibrated in accordance with EN 12845 standard
  • Quick installation thanks to preinstalled hydraulic and electric components on the discharge side
Series description
Wilo-SiFire FIRST

Design

Pressure-boosting systems for firefighting in accordance with EN 12845.

Depending on the model, composed of 1 horizontal base plate pump – EN 733 – with spacer coupling or cardanic joint, electrical or diesel motor and electrical multistage vertical jockey pump.

Application

Fully automatic water supply for fire-extinguishing systems with sprinklers in residential, commercial and public buildings, hotels, hospitals, department stores, and for office or industrial buildings.

Equipment/function

  • 1 horizontal base plate pump per system from 32-200 to 100-200 series, with IE3 equivalent standard motor or diesel engine.
  • Diaphragm, to avoid over heating at zero flow, directly installed on the main pump housing.
  • Jockey pump from MVIL-1 series
  • One controller fixed on robust supports. Model E for electric motor and D for diesel engine, both equipped with a firefighing dedicated controller, plus additional control J for jockey pump, if present.
  • Electro galvanised steel base frame.
  • Pipe work made of steel and epoxy painted. Manifold with flanges.
  • Shut-off butterfly valve with security lock on discharge side of each pump.
  • Non-return valve, on discharge side of each pump.
  • One circuit with double pressure switch, manometer, non return valve, valve, for main pump for automatic start.
  • Concentric cone on discharge side on main pump, for speed limitation according to prameters requested in EN 12845 standard.
  • Connection DN 2" for the priming tank per pump.
  • Pressure gauge on discharge side.
  • Only for diesel engine model:
    • 2 batteries on the base plate and battery chargers in the control box.
    • Separated fuel tank with level sensor and adequate volume to allow 6 hours operating autonomy.
  • Accessories on request:
    • Horizontal priming tank 500 L, with floating valve and pressure switch for low level alarm.
    • Flow meter
    • Kit eccentric cone on suction side complete of butterfly valve with hand lever or hand wheel.
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Antivibration sleeve for manifold
    • Remote panel to transfer alarms level A+B
    • Densimeter for battery
    • Spare part kit for diesel engine
    • Silencer (30 dBA) for diesel engine
    • Hydraulic heat exchanger for diesel engine

Typekey

NO VALUE

Technical data

Allowed fluid:

  • Non-aggressive clean water, free of abrasive or long fiber substances

Application field:

  • Power supply 3~400 V, 50 Hz (1~230 V, 50 Hz for Jockey pump and Diesel pump control panel)
  • Fluid temperature max. +25 °C
  • Ambiant temperature min/max. +4 to +40 °C (+10 to +40 °C if diesel pump is installed)
  • Maximum operating pressure 16 bar (12 bar with Jockey pump)
  • Maximum inlet pressure 6 bar
  • Flow from 10 to 320 m³/h
  • Maximum head 95 m

Pump impellers:

  • Bronze for main horizontal base plate pump
  • Stainless steel for vertical multistage jockey pump

Electrical Motor:

  • IE3 standard motors
  • Maximum power 55 kW
  • Nominal speed 2900 rpm
  • Protection class IP55

Diesel engine:

  • Direct injection or supercharged diesel motor with air or water cooling.
  • Maximum power 66 kW
  • Forced lubrification with gear pump and oil filter
  • Cooling depending on the power: Up to 17,7 kW with air flow, direct or with water in closed circuit with radiator. From 26,5 kW with heat exchanger water/water.

Other:

  • Epoxy painted pipes and hydraulic connections
  • Discharge nominal connection diameters DN 50 until DN 150 - EN 1092, PN 16
  • Suction nominal connection diameters DN 50 until DN 125 - EN 1092, PN 16
  • Protection class for Control box: IP54

Materials

For horizontal base plate pump

  • Impellers made of Bronze CuSn10 or CuAl10Fe5Ni5
  • Wear rings made of AISI316L/1.4409 stainless steel
  • Pump housing made of cast iron EN-GJL-250
  • Shaft made of AISI420/1.4021 stainless steel

For Jockey pump

  • Impellers made of AISI304/1.4301 stainless steel
  • Pump housing made of cast iron EN-GJL-250
  • Shaft made of AISI304/1.4301 stainless steel
  • O-ring-seals made of EPDM

Construction

  • Base frame: Made of electro galvanised steel profiles, provided with brakets for control boxes. On the bottom part, special rectangular holes for forklift and integrated hooks for lifting straps.
  • Pipe work: Complete pipe work with flanges made of epoxy painted steel, suitable for connection of all commonly used piping materials; the pipe work is sized corresponding to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 horizontal base plate pump – EN 733 – with spacer coupling, electrical or diesel motor. Back pull out model for easy access to pump internal components without moving motor or pipes.
  • Fittings: For main pump, each pump is fitted on discharge side with a butterfly valve and non return valve, both with epoxy painted and adapted for flanged connection.
  • Tank: Separated fuel tank made of epoxy painted steel with leackage bacin.
  • Sensors and display: 2 Pressure switch 2/16 bar per pump located on the discharge side for activating the pump start through the control box controller. Discharge-side pressure gauge (ø 63 mm) located close to the pressure switches.
  • Control device/controller: The system is standard-equipped with control box for electric or diesel motor and a jockey pump controller, if present.

Scope of delivery

  • Factory-mounted, ready-for-installation pressure-boosting system, which has been checked for functionality and impermeability
  • Installation and operating instructions
  • Required accessories on request
Documents

Installation and operating instructions

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Page format 209.9 x 297.0 mm
Number of pages 451
PDF (18 MB)

Wilo-SiFire FIRST

Article Number 4243594
Edition 2020-12
Page format 209.9 x 297.0 mm
Number of pages 84
PDF (12 MB)

General overview

General Overview 2022 - International version

Edition 2022
Page format 209.9 x 297.0 mm
Number of pages 78
PDF (38 MB)

Certificate REACH

REACH Regulation

Edition 2021-05
Page format 209.9 x 297.0 mm
Number of pages 4
PDF (212 KB)
Product list
Number of results: 200
29 … 323 m³/h
[200]
Product descriptionSystem output without standby pump QMaximum operating pressure PNGross weight, approx. mArticle number
SiFire-FIRST-32/200-154-4,2D
29 m³/h
16 bar
395 kg
4240808
SiFire-FIRST-32/200-154-4,2DJ
29 m³/h
12 bar
445 kg
4240861
SiFire-FIRST-32/200-154-4E
29 m³/h
16 bar
318 kg
4240702
SiFire-FIRST-32/200-154-4EJ
29 m³/h
12 bar
368 kg
4240755
SiFire-FIRST-32/200-172-5,5E
34 m³/h
16 bar
332 kg
4240703
SiFire-FIRST-32/200-172-5,5EJ
34 m³/h
12 bar
381 kg
4240756
SiFire-FIRST-32/200-172-6,8D
34 m³/h
16 bar
412 kg
4240809
SiFire-FIRST-32/200-172-6,8DJ
34 m³/h
12 bar
461 kg
4240862
SiFire-FIRST-32/200-182-6,8D
36 m³/h
16 bar
412 kg
4240810
SiFire-FIRST-32/200-182-6,8DJ
36 m³/h
12 bar
461 kg
4240863
SiFire-FIRST-32/200-182-7,5E
36 m³/h
16 bar
338 kg
4240704
SiFire-FIRST-32/200-182-7,5EJ
36 m³/h
12 bar
388 kg
4240757
SiFire-FIRST-32/200-191-7,5E
37 m³/h
16 bar
338 kg
4240705
SiFire-FIRST-32/200-191-7,5EJ
37 m³/h
12 bar
388 kg
4240758
SiFire-FIRST-32/200-191-10,5D
37 m³/h
16 bar
428 kg
4240811
SiFire-FIRST-32/200-191-10,5DJ
37 m³/h
12 bar
478 kg
4240864
SiFire-FIRST-32/200-200-10,5D
39 m³/h
16 bar
428 kg
4240812
SiFire-FIRST-32/200-200-10,5DJ
39 m³/h
12 bar
478 kg
4240865
SiFire-FIRST-32/200-200-11E
39 m³/h
16 bar
424 kg
4240706
SiFire-FIRST-32/200-200-11EJ
39 m³/h
12 bar
474 kg
4240759
SiFire-FIRST-32/250-198-6,8D
31 m³/h
16 bar
417 kg
4240813
SiFire-FIRST-32/250-198-6,8DJ
31 m³/h
12 bar
467 kg
4240866
SiFire-FIRST-32/250-198-7,5E
31 m³/h
16 bar
344 kg
4240707
SiFire-FIRST-32/250-198-7,5EJ
31 m³/h
12 bar
393 kg
4240760
SiFire-FIRST-32/250-222-10,5D
34 m³/h
16 bar
434 kg
4240814
SiFire-FIRST-32/250-222-10,5DJ
34 m³/h
12 bar
483 kg
4240867
SiFire-FIRST-32/250-222-11E
34 m³/h
16 bar
430 kg
4240708
SiFire-FIRST-32/250-222-11EJ
34 m³/h
12 bar
479 kg
4240761
SiFire-FIRST-32/250-234-12,9D
35 m³/h
16 bar
450 kg
4240815
SiFire-FIRST-32/250-234-12,9DJ
35 m³/h
12 bar
500 kg
4240868
SiFire-FIRST-32/250-234-15E
35 m³/h
16 bar
442 kg
4240709
SiFire-FIRST-32/250-234-15EJ
35 m³/h
12 bar
491 kg
4240762
SiFire-FIRST-32/250-246-15E
37 m³/h
16 bar
442 kg
4240710
SiFire-FIRST-32/250-246-15EJ
37 m³/h
12 bar
491 kg
4240763
SiFire-FIRST-32/250-246-17,7D
37 m³/h
16 bar
450 kg
4240816
SiFire-FIRST-32/250-246-17,7DJ
37 m³/h
12 bar
500 kg
4240869
SiFire-FIRST-32/250-262-17,7D
39 m³/h
16 bar
491 kg
4240817
SiFire-FIRST-32/250-262-17,7DJ
39 m³/h
12 bar
540 kg
4240870
SiFire-FIRST-32/250-262-18,5E
39 m³/h
16 bar
455 kg
4240711
SiFire-FIRST-32/250-262-18,5EJ
39 m³/h
12 bar
505 kg
4240764
SiFire-FIRST-40/200-188-6,8D
53 m³/h
16 bar
415 kg
4240819
SiFire-FIRST-40/200-188-6,8DJ
53 m³/h
12 bar
465 kg
4240872
SiFire-FIRST-40/200-188-7,5E
53 m³/h
16 bar
341 kg
4240713
SiFire-FIRST-40/200-188-7,5EJ
53 m³/h
12 bar
391 kg
4240766
SiFire-FIRST-40/200-205-10,5D
62 m³/h
16 bar
432 kg
4240820
SiFire-FIRST-40/200-205-10,5DJ
62 m³/h
12 bar
481 kg
4240873
SiFire-FIRST-40/200-205-11E
62 m³/h
16 bar
428 kg
4240714
SiFire-FIRST-40/200-205-11EJ
62 m³/h
12 bar
477 kg
4240767
SiFire-FIRST-40/200-212-12,9D
66 m³/h
16 bar
448 kg
4240821
SiFire-FIRST-40/200-212-12,9DJ
66 m³/h
12 bar
498 kg
4240874