Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
VeroTwin-DP-E 40/120-1,5/2-R1 | Wilo
Similar to figure

VeroTwin-DP-E 40/120-1,5/2-R1

Article number: 2159005
Technical data
Tender text

Glanded twin-head pump with in-line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things. Three-phase AC motor with frequency converter

Design:

  • Single-stage low-pressure centrifugal pump with one-piece shaft
  • Spiral housing, in-line design
  • PN 16 flange – drilled according to EN 1092-2
  • Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor)
  • Pump housing and motor flange with cataphoretic coating as standard
  • Mechanical seal for water feed up to T=120 °C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 °C. Other mechanical seals or other fluids/temperatures on request.

Accessories:

  • Mounting brackets for fixing to the foundation
  • IR-Monitor
  • IF module PLR
  • IF module LON
  • IF module Modbus
  • IF module BACnet
  • IF module CAN
  • Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1

Standard equipment:

  • One-button manual operation level for:
    • Pump On/Off
    • Setpoint and speed adjustment
    • Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
    • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
    • Configuration of operating parameters
    • Fault acknowledgement
  • Pump display for displaying:
    • Control mode
    • Setpoint (e.g. differential pressure or speed)
    • Error and warning messages
    • Actual values (e.g. power consumption, actual value of the sensor)
    • Operating data (e.g. operating hours, energy consumption)
    • Status data (e.g. status of SSM and SBM relay)
    • Device data (e.g. pump name)

Additional functions:

  • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in dual pump operation), analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR-Stick/IR-Monitor, plug-in position for Wilo IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
  • Adjustable time interval for pump cycling (in dual pump mode)
  • Integrated full motor protection
  • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
  • Access disable
  • Different operation levels: Standard / Service
Operating Data
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 120 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Maximum operating pressure PN 10 bar
Minimum efficiency index (MEI) ≥0.4
Motor data
Motor efficiency class IE4
Interference emission EN 61800-3
Interference immunity EN 61800-3
Mains connection
  • 3~380 V, 50/60 Hz
  • 3~400 V, 50/60 Hz
  • 3~440 V, 50/60 Hz
Rated power P2 1500 W
Max. speed nmax 2930 1/min
Rated current IN 5 A
Insulation class F
Protection class motor IP55
Motor protection PTC integrated
Materials
Pump housing Grey cast iron
Impeller PPE/PS-GF30
Shaft Stainless steel
Shaft seal AQ1EGG
Lantern Grey cast iron
Installation dimensions
Pipe connection on the suction side DNs DN 40
Pipe connection on the discharge side DNd DN 40
Port-to-port length L0 320 mm
Ordering information
Brand Wilo
Product description VeroTwin-DP-E 40/120-1,5/2-R1
Net weight, approx. m 71 kg
Article number 2159005
Documents

Installation and operating instructions

Wilo-VeroLine-IP-E Wilo-VeroTwin-DP-E

Article Number 2144990
Edition 2017-11
Page format 209.9 x 297.0 mm
Number of pages 236
PDF (21 MB)

Certificate REACH

REACH Regulation

Edition 2021-05
Page format 209.9 x 297.0 mm
Number of pages 4
PDF (262 KB)

BIM/CAD

3D_DWG

DP-E40/120-1,5/2-R1

DWG (3 MB)

3D_STEP

DP-E40/120-1,5/2-R1

STP (4 MB)

2D_DWG_TOP

DP-E40/120-1,5/2-R1

DWG (22 KB)

2D_DWG_FRONT

DP-E40/120-1,5/2-R1

DWG (42 KB)

2D_DWG_RIGHT

DP-E40/120-1,5/2-R1

DWG (37 KB)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Commissioning
Commissioning Glanded pumps
    
2219391

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.