FLA Compact-2 Helix V 1611 DS16
Data sheet
Hydraulic data
-
Maximum inlet pressure p inl6 bar
-
Maximum operating pressure PN16 bar
-
Number of pumps2
-
Min. fluid temperature Tmin3 °C
-
Max. fluid temperature Tmax40 °C
-
Min. ambient temperature Tmin5 °C
-
Max. ambient temperature Tmax40 °C
Motor data
-
Mains connection3~400 V, 50 Hz
-
Rated power P27.50 kW
-
Rated current IN13.70 A
-
Power factor cos φ0.88
-
Rated speed n2900 1/min
-
Activation typeDirect/Star-delta
-
Protection class motorIP55
-
Protection class switchgearIP54
Materials
-
Pump housingStainless steel
-
ImpellerStainless steel
-
ShaftStainless steel
-
Gasket materialEPDM
-
Pipework materialStainless steel
Installation dimensions
-
Pipe connection on the suction side DNs-
-
Pipe connection on the pressure side DNdR 2½
Information for order placements
-
BrandWilo
-
Product descriptionFLA Compact-2 Helix V 1611 DS16
-
EAN number4048482427768
-
Article number2540137
-
Net weight, approx. m398 kg
-
Gross weight, approx. m466.0 kg
-
Length with packaging2000 mm
-
Height with packaging1930 mm
-
Width with packaging1600 mm
-
Packaging propertyTransport packaging
-
Packaging typeSpecial pallet
-
Minimum order quantity1
Tender text
Pressure boosting system as a fully automatic double pump compact unit (100% redundancy) for fire fighting purposes in accordance with DIN 14462, consisting of:
Break tank (540 l) with TZW approval for incoming water. Non self-priming, vertical stainless steel high-pressure multistage centrifugal pumps with three-phase AC motor. Shaft sealing by standard cartridge mechanical seal (Helix pumps). Diaphragm pressure vessel (capacity 8 l), integrated non-return valve, shut-off valves on suction and pressure side (secured against unauthorised operation), pressure switch and pressure gauge for automatic system control. Comes as standard with pump protection by means of minimum volume discharge via bypass circuit without auxiliary energy.
Switchgear FLA for fire extinguishing systems according to DIN 14462, designed in accordance with TÜV requirements.
Switchgear integrated in a sheet metal enclosure, painted in RAL 7035. With built-in motor protection only for signalling of faults. Motor protection is active in the test run.
Switch for Manual-Automatic mode Control of the pumps by pressure switch in automatic mode; expandable to up to 8 contacts (in series connection), e.g. External On/Off, limit switch etc. (more than 8 contacts on request). All pressure switch and limit switch signals are monitored for wire break and short-circuit.
System with programmable time switch for daily test run and programmable follow-up time. Dry-running protection relay, e.g. for connection of low water float switches from the WILO FLA break tanks or level electrodes, etc.; low water status only for signalling of faults. Protection against low water level is active in the test run.
With signal lamps for ready to run (green), pump ON (green), fault (red), operation started externally (white) and potential-free contacts for ready to run, pump ON and collective fault signal.
The system has been mounted on the base frame with wires and pipes are ready for connection.
The tank can be connected directly to the suction side of the pumps.
Additional text for systems with max. discharge pressure (inlet pressure + zero-delivery head) > 8.0 bar: The customer must take suitable measures to ensure that the flow pressure of 8 bar and the resting pressure of 12 bar are not exceeded at any fire hose reel.
Operating data
-
Fluid mediaWater
-
Max. delivery head Hmax142.4 m
-
Number of pumps2
-
Fluid temperature T3 °C
-
Ambient temperature T5 °C
-
Maximum operating pressure PN16 bar
-
Maximum inlet pressure p inl6 bar
Motor data
-
Mains connection3~400 V, 50 Hz
-
Rated power P27.50 kW
-
Rated current IN13.70 A
-
Power factor cos φ0.88
-
Rated speed n2900 1/min
-
Activation typeDirect/Star-delta
-
Protection class motorIP55
-
Protection class switchgearIP54
Materials
-
Pump housingStainless steel
-
ImpellerStainless steel
-
ShaftStainless steel
-
Shaft sealQ1BE3GG
-
Gasket materialEPDM
-
Pipework materialStainless steel
Installation dimensions
-
Pipe connection on the suction side DNs-
-
Pipe connection on the pressure side DNdR 2½
Information for order placements
-
BrandWilo
-
Product descriptionFLA Compact-2 Helix V 1611 DS16
-
Net weight, approx. m398 kg
-
Article number2540137
Wiring diagram
FLA system, Υ-Δ starting

X0: Mains connection
X1: Pump connection
X2: Pressure switch/limit switch loop
X3: Protection against low water level 1, 2 float switches, level sensor; 1, 2, 3 level electrodes
X5: potential-free contact 1, 2, 3 pump On (not in test run mode)
X8: potential-free contact 1, 2 operational readiness; 3, 4 pump On; 5, 6, 7 collective fault signal; 8, 9 emergency spillway monitoring (float switch); 10, 11 emergency spillway monitoring (signal)
X9: potential-free contact 1, 2 mains power supply monitoring
X10: Service terminals (attention: 230 VAC at pump start)

Ordering information
Information for order placements
-
BrandWilo
-
Product descriptionFLA Compact-2 Helix V 1611 DS16
-
EAN number4048482427768
-
Article number2540137
-
Gross weight, approx. m466.0 kg
-
Net weight, approx. m398 kg
-
Overall length L2245.0 mm
-
Height without packaging H1790 mm
-
ColourGreen/black/silver
-
Packaging propertyTransport packaging
-
Packaging typeSpecial pallet
-
Number per layer1
-
Width without packaging B800.0 mm
-
Minimum order quantity1
-
Pieces per pallet1
-
Date of sales availability2014-03-01
-
Date of introduction2014-03-01
Downloads

Wilo-FLA Compact
Article Number | 2537431 |
Edition | 2019-07 |
Version number | 03 |
Page format | 209.9 x 297.0 mm |
Number of pages | 96 |
PDF (5 MB)
Download