Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-DrainLift WS 40/50 Basic | Wilo
Your advantages
Wilo-DrainLift WS 40/50

Your advantages

  • Pressure-tight chamber for subterranean and above ground installation
  • Flexible due to freely selectable inlets
  • Large tank volume
  • Including pipework, level control, switchgear and pump
Series description
Wilo-DrainLift WS 40/50 Basic

Design

Plastic chamber as single or double pump system. Suitable for underground installation or building installation.

Application

  • As a lifting unit within buildings (above ground installation).
  • As a pump chamber outside buildings (concealed floor installation).
  • For backflow resistant drainage of
    • Drainage points below the backflow level
    • Drainage points that cannot be drained via a natural downward slope.

Liquid

For collection and pumping of the following in commercial areas:

  • Sewage, with or without faeces

Sewage pumping according to 12050

  • EN 12050-1:
    • DrainLift WS 50E/D Basic with Rexa MINI3 ...
    • DrainLift WS 50E/D Basic with Rexa UNI ...
  • EN 12050-2:
    • DrainLift WS 40E/D Basic with Rexa MINI3 ...

Equipment/function

  • Shut-off ball valve
  • Non-return valve
  • Switchgear
  • Level controller (floater or sensor)
  • Submersible pump with thermal motor monitoring
  • Ready-to-plug

Typekey

Example:

DrainLift WS 40E Basic/Rexa ...

DrainLift

Product family

WS

Pump chamber

40

Size

E

Chamber design:

  • E = Single-pump system
  • D = Double-pump system

Basic

Pump chamber with pump and level control

Rexa ...

Installed pump

Technical data

  • Vessel volume: 255 l/67 US.liq.gal. (WS...E)/400 l/105 US.liq.gal. (WS...D)
  • Maximum pressure in the discharge pipeline: 1.5 bar (22 psi)
  • Discharge port: G 2/50 mm (WS 40), G 2½ /63 mm (WS 50)
  • Inlet connection: DN 100/150/200
  • Ventilation connection: 75 mm (3 in)
  • Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
  • Fluid temperature: 3 ... 40 °C (37 ... 104 °F)
  • Max. ambient temperature: 3 ... 40 °C (37 ... 104 °F)

Materials

Chamber

  • Pump chamber: PE
  • Pipework: 1.4404 (AISI 316L)
  • Stopcock: PVC
  • Non-return valve: Grey cast iron

Pump

  • Rexa MINI3
    • Hydraulics housing: EN-GJL-200 (ASTM A48 Class 30)
    • Impeller: PK-GF30
    • Motor housing: 1.4301 (AISI 304)
    • Seal on the pump side: C/MgSi
    • Seal on the motor side: NBR
  • Rexa UNI
    • Hydraulics housing: PP-GF30
    • Impeller: PP-GF30
    • Motor housing: 1.4301 (AISI 304)
    • Seal on the pump side: SiC/SiC
    • Seal on the motor side: C/Cr

Construction

DrainLift WS 40E Basic (1~230 V)

Chamber

Pump chamber with optimised geometry for deposit-free operation. Chamber component with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upward curved pump chamber cover can be walked on and can be loaded with max. 200 kg. For the building installation, the pump chamber is equipped with a floor fixation.

Pipework

  • Discharge pipe with threaded connection on the pump side
  • Shut-off ball valve
  • Non-return ball valve

Pump

Submersible sewage pump for single-phase current. Surface-cooled motor with thermal motor protection (self-switching) and plug.

Level control

The level is controlled via the float switch of the pump.

DrainLift WS 40E Basic (3~ 400 V)

Chamber

Pump chamber with optimised geometry for deposit-free operation. Chamber component with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upward curved pump chamber cover can be walked on and can be loaded with max. 200 kg. For the building installation, the pump chamber is equipped with a floor fixation.

Pipework

  • Discharge pipe with threaded connection on the pump side
  • Shut-off ball valve
  • Non-return ball valve

Pump

Submersible sewage pump for three-phase alternating current (three-phase current connection). Surface-cooled motor with thermal motor protection and bare cable end.

Level control

The level is controlled via a separate float switch and a switchgear.

DrainLift WS 40D Basic

Chamber

Pump chamber with optimised geometry for deposit-free operation. Chamber component with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upward curved pump chamber cover can be walked on and can be loaded with max. 200 kg. For the building installation, the pump chamber is equipped with a floor fixation.

Pipework

  • Discharge pipe with threaded connection on the pump side
  • Shut-off ball valve
  • Non-return ball valve

Pump

Submersible sewage pump for three-phase alternating current (three-phase current connection). Surface-cooled motor with thermal motor protection and bare cable end.

Level control

The level is controlled via a level sensor and a switchgear.

DrainLift WS 50E Basic

Chamber

Pump chamber with optimised geometry for deposit-free operation. Chamber component with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upward curved pump chamber cover can be walked on and can be loaded with max. 200 kg. For the building installation, the pump chamber is equipped with a floor fixation.

Pipework

  • Discharge pipe with threaded connection on the pump side
  • Shut-off ball valve
  • Non-return ball valve

Pump

Submersible sewage pump for single-phase current. Surface-cooled motor with thermal motor protection (self-switching) and plug.

Level control

The level is controlled via the float switch of the pump.

DrainLift WS 50D Basic

Chamber

Pump chamber with optimised geometry for deposit-free operation. Chamber component with finning for high inherent stability and anti-buoyancy. The inlets are freely configurable. Two lifting eyes are integrated for attaching the lifting accessory. The upward curved pump chamber cover can be walked on and can be loaded with max. 200 kg. For the building installation, the pump chamber is equipped with a floor fixation.

Pipework

  • Discharge pipe with threaded connection on the pump side
  • Shut-off ball valve
  • Non-return ball valve

Pump

Submersible sewage pump for three-phase alternating current (three-phase current connection). Surface-cooled motor with thermal motor protection and bare cable end.

Level control

The level is controlled via a level sensor and a switchgear.

Scope of delivery

DrainLift WS 40E Basic (1~230 V)

  • Plastic chamber with installed pipework, pump and level control
    • Pipework with shut-off ball valve and non-return valve
    • Pump with float switch and plug
  • Chamber cover with gasket
  • HT double socket 50 mm (2 in) for evacuation connection
  • Inlet set with hole saw 124 mm (5 in) and gasket DN100
  • Floor fixation
  • Installation and operating instructions

DrainLift WS 40E Basic (3~400 V)

  • Plastic chamber with installed pipework, pump and level control
    • Pipework with shut-off ball valve and non-return valve
    • Pump
    • Switchgear with float switch and plug
  • Chamber cover with gasket
  • HT double socket 50 mm (2 in) for evacuation connection
  • Inlet set with hole saw 124 mm (5 in) and gasket DN100
  • Floor fixation
  • Installation and operating instructions

DrainLift WS 40D Basic (1~230 V)

  • Plastic chamber with installed pipework, pump and level control
    • Pipework with shut-off ball valve and non-return valve
    • Pump with plug
    • Switchgear with level sensor and plug
  • Chamber cover with gasket
  • HT double socket 50 mm (2 in) for evacuation connection
  • Inlet set with hole saw 124 mm (5 in) and gasket DN100
  • Floor fixation
  • Installation and operating instructions

DrainLift WS 40D Basic (3~400 V)

  • Plastic chamber with installed pipework, pump and level control
    • Pipework with shut-off ball valve and non-return valve
    • Pump
    • Switchgear with level sensor and plug
  • Chamber cover with gasket
  • HT double socket 50 mm (2 in) for evacuation connection
  • Inlet set with hole saw 124 mm (5 in) and gasket DN100
  • Floor fixation
  • Installation and operating instructions

DrainLift WS 50E Basic

  • Plastic chamber with installed pipework, pump and level control
    • Pipework with shut-off ball valve and non-return valve
    • Pump with float switch and plug
  • Chamber cover with gasket
  • HT double socket 50 mm (2 in) for evacuation connection
  • Inlet set with hole saw 124 mm (5 in) and gasket DN100
  • Floor fixation
  • Installation and operating instructions

DrainLift WS 50D Basic

  • Plastic chamber with installed pipework, pump and level control
    • Pipework with shut-off ball valve and non-return valve
    • Pump with plug
    • Switchgear with level sensor and plug
  • Chamber cover with gasket
  • HT double socket 50 mm (2 in) for evacuation connection
  • Inlet set with hole saw 124 mm (5 in) and gasket DN100
  • Floor fixation
  • Installation and operating instructions

Accessories

  • Pump chamber extension
  • Clamp bolting
  • Diaphragm hand pump
  • Alarm switchgear
  • Additionally for chambers with switchgear:
    • Float switch to detect high water levels
    • Horn
    • Flash light
Documents

Installation and operating instructions

Wilo-DrainLift WS 40/50 Basic

Article Number 6087354
Edition 06
Number of pages 40
Language en
PDF (6 MB)

Installation and operating instructions (digital)

DrainLift WS 40/50 Basic

Article Number 6087354
Edition 2023-07
Language bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, lt, lv, mk, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk, zh
HTML (10 MB)

Certification booklet

Wilo-Drainlift WS 40/50, Wilo-DrainLift WS 40/50 Basic

Article Number 6069562
Edition 2021-07
Number of pages 72
Language language neutral
PDF (4 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (279 KB)