Data sheet
| Hydraulic data | |
|---|---|
| Minimum efficiency index (MEI) | 0.4 |
| Maximum operating pressure PN | 16 bar |
| Min. fluid temperature Tmin | -20 °C |
| Max. fluid temperature Tmax | 140 °C |
| Min. ambient temperature Tmin | -30 °C |
| Max. ambient temperature Tmax | 50 °C |
| Drive | |
|---|---|
| Mains connection | 3~400 V, 50/60 Hz |
| Motor efficiency class | IE5 |
| Power consumption P1 max | 5.90 kW |
| Rated power P2 | 5.5 kW |
| Max current Imax | 10.5 A |
| Emitted interference | EN 61800-3 |
| Interference resistance | EN 61800-3 |
| Insulation class | F |
| Protection class motor | IP55 |
| Motor protection | PTC integrated |
| Materials | |
|---|---|
| Pump housing | Grey cast iron |
| Impeller | Grey cast iron |
| Shaft | Stainless steel |
| Shaft seal | Q7Q7X4GG |
| Lantern | 5.1301/EN-GJL-250 KTL-coated |
| Approved liquids (other liquids upon request) | |
|---|---|
| Heating water (as per VDI 2035) | yes |
| Heat carrier oil | Special version at additional charge |
| Cooling and cold water circulation systems | yes |
| Water-glycol mixtures (at 20 – 40 vol. % glycol and fluid temperature ≤ 40 °C) | yes |
| Installation dimensions | |
|---|---|
| Port-to-port length L0 | 500 mm |
| Pipe connection, suction side DNs | DN 100 |
| Pipe connection, discharge side DNd | DN 100 |
Pump curves
Dimensions and dimensions drawings
Stratos GIGA2.0-I 100/1-14/5,5-R1-S1

Wiring diagram
Wilo-Stratos GIGA2.0

| Designation | Assignment | Note |
| Analogue IN (AI 1) | + 24 V + In 1 → - GND | Signal type:
Dielectric strength:
Power supply:
|
| Analogue IN (AI 2) | + In 2 → | |
| - GND | ||
| Analogue IN (AI 3) | + 24 V + In 3 → - GND | Signal type:
Dielectric strength:
Power supply:
|
| Analogue IN (AI 4) | + In 4 → | |
| - GND | ||
| Digital IN (DI 1) | DI 1 → + 24 V | Digital inputs for potential-free contacts::
|
| Digital IN (DI 2) | DI 2 → + 24 V | |
| Wilo Net | ↔ H ↔ L GND H/L | |
| SSM | COM ← NO ← NC | Potential-free changeover contact load:
|
| SBM | COM ← NO ← NC | Potential-free changeover contact load:
|
| Mains connection | L1 L2 L3 |
Acoustics
Airborne sound data sheet
| Airborne sound power LW,A | |
|---|---|
| Octave band centre frequency in Hz | Level in dB(A), ref. 20µPa |
| L63 | 31.4 |
| L125 | 49.8 |
| L250 | 59.8 |
| L500 | 62.9 |
| L1000 | 67.7 |
| L2000 | 63.6 |
| L4000 | 56.7 |
| L8000 | 48 |
| Airborne sound-power level (total) Lw | 71 |
| Airborne sound pressure Lp,A,1m | |
|---|---|
| Octave band centre frequency in Hz | Level in dB(A), ref. 1pW |
| L63 | 17.4 |
| L125 | 35.8 |
| L250 | 45.8 |
| L500 | 48.9 |
| L1000 | 53.7 |
| L2000 | 49.6 |
| L4000 | 42.7 |
| L8000 | 34 |
| Airborne sound-pressure level (total) Lp | 57 |
Ordering information
| Product data | |
|---|---|
| Brand | Wilo |
| Product description | Stratos GIGA2.0-I 100/1-14/5,5-R1-S1 |
| Article number | 2204959 |
| EAN number | 4062679108957 |
| Colour | Green/black/grey |
| Minimum order quantity | 1 |
| Date of sales availability | 2023-03-21 |
| Packaging | |
|---|---|
| Packaging type | Euro pallet |
| Packaging property | Transport packaging |
| Pieces per pallet | 1 |
| Number per layer | 1 |
| Dimension, weight | |
|---|---|
| Length with packaging | 1200 mm |
| Length L | 743 mm |
| Height with packaging | 800 mm |
| Height H | 532 mm |
| Width with packaging | 800 mm |
| Width W | 367 mm |
| Gross weight, approx. m | 153 kg |
| Net weight, approx. m | 106 kg |
High-efficiency in-line pump with EC motor of efficiency class IE5 in accordance with IEC 60034-30-2, hydraulic minimum efficiency index MEI ≥ 0.7 or MEI ≥ 0.4 (depending on the pump type) and electronic power adjustment in glanded pump design. The pump is configured as a single-stage low-pressure centrifugal pump with flange connection and mechanical seal. The Stratos GIGA2.0-I has been predominantly designed for pumping heating water (acc. to VDI 2035), chilled water and water-glycol mixtures without abrasive substances in heating, air-conditioning and cooling systems.
Design ...-R1-S1:
- Single-stage low-pressure centrifugal pump with one-piece shaft in close-coupled design or split shaft (depending on the pump type)
- Spiral housing in in-line design (suction and discharge ports with the same flanges in a line)
- PN 16 flange – in accordance with EN 1092-2
- Pressure measuring connections (R 1/8) for retrofitting of a differential pressure sensor (version ...-R1 without differential pressure sensor)
- Pump housing and motor flange with cataphoretic coating as standard
- Mechanical seal S1 recommended for water-glycol mixtures with glycol proportions up to max. 50% by volume and a fluid temperature of -20 °C up to max. +90 °C – +110 °C and also if there is oil in the water-glycol mixture.
- Connection voltages:
- 3~440 V ±10% 50/60 Hz; 3~400 V ±10% 50/60 Hz; 3~380 V -5% +10% 50/60 Hz
- Version M-: 1~220 V – 240 V (±10%), 50/60 Hz
- Compliance with electromagnetic compatibility without additional measures
- Interference emission for residential environment according to EN 61800-3:2018
- Interference immunity for industrial environments according to EN 61800-3:2018
Control modes:
- Constant speed (n-const.)
- Constant temperature (T-const.)
- Constant differential temperature (dT-const.)
- User-defined PID control
- Only possible with differential pressure sensor:
- Permanent, automatic power adjustment to system requirements without setpoint specification Wilo Dynamic Adapt plus (factory setting).
- Needs-based volume flow optimisation of the feeder pump through connectivity and communication between multiple secondary pumps (Multi-Flow Adaptation).
- Constant volume flow (Q-const.)
- Variable differential pressure (dp-v) with the option to set the nominal duty point Q and H
- Constant differential pressure (dp-c)
- Differential pressure control (dp-c) to a remote point in the pipe network (index circuit evaluator)
Functions:
- Selection of the field of application in the setting assistant
- Operating modes of twin-head pump: Main/standby operation
- Switchover between heating and cooling mode (automatic, external or manual)
- Ability to save and restore configured pump settings (3 restoration points)
- Fault and warning messages shown in plain text with advice on resolving the issue
- Integrated full motor protection
- Only possible with differential pressure sensor:
- Heat quantity measurement
- Cooling quantity measurement
- Adjustable volume flow limiter using the Q-Limit function (Qmin. and Qmax.)
- Pump automatically deactivates when no flow rate is detected (No-Flow Stop)
- Efficiency-optimised parallel operation for dp-c and dp-v
Display in the "Home screen" of the graphic display:
- Control mode currently set
- Current setpoint
- Current volume flow (only if a differential pressure sensor is connected)
- Current fluid temperature (only if temperature sensor is connected)
- Current power consumption
- Cumulative electric consumption
Version:
- 4 configurable analogue inputs: 0-10 V, 2-10 V, 0-20 mA, 4-20 mA and commercially available PT1000 (only on two analogue inputs); +24 V DC power supply
- 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, heating/cooling, manual override (uncoupled from building automation), operation lock (key lock and remote operation configuration protection))
- 2 configurable signal relays for run signals and fault messages
- Slot for Wilo-CIF modules with interfaces for building automation (BA) (optional accessories: CIF modules Modbus RTU, BACnet MS/TP, LON, PLR, CAN)
- Wilo Net as a Wilo system bus for communication between Wilo products, e.g. Multi-Flow Adaptation; dual-pump operation
- Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction
- Rotatable, graphic colour display (4.3 inches) with one button manual operation level
- Bluetooth interface via Wilo-Smart Connect module BT
- Use the Wilo-Assistant app to read and set operating data and –among other things– set up a commissioning protocol through the Bluetooth interface
- Integrated dual-pump management (twin-head pumps are prewired) when using 2 single pumps as two-pump unit (connection via Wilo Net)
- Cable break detection when using an analogue signal (in connection with 2 – 10 V or 4 – 20 mA)
- Time stamp for error/warnings and historical operating data
- Continuous operating data memory
- Standard condensate drainage holes in the motor housing (closed upon delivery)
- Air vent valve on the lantern
Scope of delivery:
- Pump
- Wilo-Smart Connect module BT
- Threaded cable glands with sealing inserts
- Installation and operating instructions
Accessories must be ordered separately:
3 mounting brackets with fixation material for installation on a base
- Blind flanges for twin-head pump housing
- Installation aid for mechanical seal (incl. mounting bolts)
- For connection to building automation:
- CIF module PLR
- CIF module LON
- CIF module BACnet MS/TP
- CIF module Modbus RTU
- CIF module CANopen
- CIF module Ethernet Multi-protocol (Modbus TCP, BACnet/IP)
- Connection M12 RJ45 CIF Ethernet
- Differential pressure sensor DPS 2 … 10 V
- Differential pressure sensor DPS 4 … 20 mA
- Temperature sensor PT1000 AA
- Sensor sleeves for the installation of temperature sensors in the pipe
| Operating data | |
|---|---|
| Min. fluid temperature Tmin | -20 °C |
| Max. fluid temperature Tmax | 140 °C |
| Min. ambient temperature Tmin | -30 °C |
| Max. ambient temperature Tmax | 50 °C |
| Maximum operating pressure PN | 16 bar |
| Minimum efficiency index (MEI) | 0.4 |
| Drive | |
|---|---|
| Mains connection | 3~400 V, 50/60 Hz |
| Motor efficiency class | IE5 |
| Power consumption P1 max | 5900 W |
| Rated power P2 | 5.5 kW |
| Max current Imax | 10.5 A |
| Max. speed nmax | 1800 1/min |
| Emitted interference | EN 61800-3 |
| Interference resistance | EN 61800-3 |
| Insulation class | F |
| Protection class motor | IP55 |
| Motor protection | PTC integrated |
| Materials | |
|---|---|
| Pump housing | Grey cast iron |
| Impeller | Grey cast iron |
| Shaft | Stainless steel |
| Shaft seal | Q7Q7X4GG |
| Lantern | 5.1301/EN-GJL-250 KTL-coated |
| Installation dimensions | |
|---|---|
| Pipe connection, suction side DNs | DN 100 |
| Pipe connection, discharge side DNd | DN 100 |
| Port-to-port length L0 | 500 mm |
| Ordering information | |
|---|---|
| Brand | Wilo |
| Product description | Stratos GIGA2.0-I 100/1-14/5,5-R1-S1 |
| Net weight, approx. m | 106 kg |
| Article number | 2204959 |