SC/SC-FC-HVAC system | Wilo
Your advantages
Wilo-SCe-HVAC system

Your advantages

  • Easy operation: Display, symbols and menu navigation analogous to the Wilo glanded pumps of the latest design
  • Easy-to-use system: System access to the service menu protected via code, error history memory with up to 16 individual messages
  • Reliable system: Permanent display of pumps and system status as well as the actual value present in the display
  • SBM and SSM as standard, other error messages/alarm signals can optionally be output via relay or via other communication tools (e.g., bus systems)
  • Advanced settings: 2 adjustable setpoints, remote setpoint adjustment possible
  • Communication capability: Connectible bus systems: BACnet, Modbus RTU (RS 485) (LON connectible via optional module)
Series description

Design

Digitally controlled, variable Smart control systems for driving glandless and glanded pumps of all makes and single and multi-pump systems.

SC version:

Control of fixed speed pumps via contactors (cascade connection)

SC-FC version:

Control of fixed speed pumps via contactors (cascade connection), but control of a pump via frequency converter as a base-load pump, control of the peak-load pumps in cascade connection

Application

For stageless power adjustment to the variable operating states of single, double or multi-pump systems (up to 4 pumps). Controlling depends on the differential pressure Δp, feed/return temperature (±T) or differential temperature (ΔT), including the free adjustment of the duty point by means of advance correction of the full-load pump output.

Equipment/function

Typekey

Technical data

Downloads

Certificate REACH (Documents)

REACH regulation

Edition 2021-10
Page format 209.9 x 297.0 mm
Number of pages 2
PDF (162 KB)
Product list
Product descriptionMax. number of controllable pumpsMax. rated current per pump IArticle number
SC-HVAC system 1x1.6A-WM (direct starting)
1
1.6 A
2545310
SC-HVAC system 2x1.6A-WM (direct starting)
2
1.6 A
2545311
SC-HVAC system 3x1.6A-WM (direct starting)
3
1.6 A
2545312
SC-HVAC system 4x1.6A-WM (direct starting)
4
1.6 A
2545313
SC-HVAC system 1x2.4A-WM (direct starting)
1
2.4 A
2545314
SC-HVAC system 2x2.4A-WM (direct starting)
2
2.4 A
2545315
SC-HVAC system 3x2.4A-WM (direct starting)
3
2.4 A
2545316
SC-HVAC system 4x2.4A-WM (direct starting)
4
2.4 A
2545317
SC-HVAC system 1x4A-WM (direct starting)
1
4 A
2545318
SC-HVAC system 2x4A-WM (direct starting)
2
4 A
2545319
SC-HVAC system 3x4A-WM (direct starting)
3
4 A
2545320
SC-HVAC system 4x4A-WM (direct starting)
4
4 A
2545321
SC-HVAC system 1x6.3A-WM (direct starting)
1
6.3 A
2545322
SC-HVAC system 2x6.3A-WM (direct starting)
2
6.3 A
2545323
SC-HVAC system 3x6.3A-WM (direct starting)
3
6.3 A
2545324
SC-HVAC system 4x6.3A-WM (direct starting)
4
6.3 A
2545325
SC-HVAC system 1x10A-WM (direct starting)
1
10 A
2545326
SC-HVAC system 2x10A-WM (direct starting)
2
10 A
2545327
SC-HVAC system 3x10A-WM (direct starting)
3
10 A
2545328
SC-HVAC system 4x10A-WM (direct starting)
4
10 A
2545329
SC-HVAC system 1x12A-WM (direct starting)
1
12 A
2545330
SC-HVAC system 2x12A-WM (direct starting)
2
12 A
2545331
SC-HVAC system 3x12A-WM (direct starting)
3
12 A
2545332
SC-HVAC system 4x12A-WM (direct starting)
4
12 A
2545333
SC-HVAC system 1x16A-WM (direct starting)
1
16 A
2545334
SC-HVAC system 2x16A-WM (direct starting)
2
16 A
2545335
SC-HVAC system 3x16A-WM (direct starting)
3
16 A
2545336
SC-HVAC system 4x16A-WM (direct starting)
4
16 A
2545337
SC-HVAC system 1x20A-WM (direct starting)
1
20 A
2545338
SC-HVAC system 2x20A-WM (direct starting)
2
20 A
2545339
SC-HVAC system 3x20A-WM (direct starting)
3
20 A
2545340
SC-HVAC system 4x20A-WM (direct starting)
4
20 A
2545341
SC-HVAC system 1x24A-WM (direct starting)
1
24 A
2545342
SC-HVAC system 2x24A-WM (direct starting)
2
24 A
2545343
SC-HVAC system 3x24A-WM (direct starting)
3
24 A
2545344
SC-HVAC system 4x24A-WM (direct starting)
4
24 A
2545345
SC-HVAC system 1x32A-WM (direct starting)
1
32 A
2545346
SC-HVAC system 2x32A-WM (direct starting)
2
32 A
2545347
SC-HVAC system 3x32A-WM (direct starting)
3
32 A
2545348
SC-HVAC system 4x32A-WM (direct starting)
4
32 A
2545349
SC-HVAC system 1x13A-WM (star-delta starting)
1
13 A
2545350
SC-HVAC system 2x13A-WM (star-delta starting)
2
13 A
2545351
SC-HVAC system 3x13A-WM (star-delta starting)
3
13 A
2545352
SC-HVAC system 4x13A-WM (star-delta starting)
4
13 A
2545353
SC-HVAC system 1x16A-WM (star-delta starting)
1
16 A
2545354
SC-HVAC system 2x16A-WM (star-delta starting)
2
16 A
2545355
SC-HVAC system 3x16A-WM (star-delta starting)
3
16 A
2545356
SC-HVAC system 4x16A-WM (star-delta starting)
4
16 A
2545357
SC-HVAC system 1x19A-WM (star-delta starting)
1
19 A
2545358
SC-HVAC system 2x19A-WM (star-delta starting)
2
19 A
2545359