Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-Economy CO-1 Helix V.../EC | Wilo
Your advantages
NEW
Wilo-Economy CO-1 Helix V.../EC

Your advantages

  • Heavy-duty system which satisfies all the requirements of DIN 1988 (EN 806)
  • High-efficiency pump hydraulics of the Helix V series in conjunction with IE3 IEC standard motors
  • The spacer coupling enables the mechanical seal to be replaced without dismantling the motor (from 11 kW)
  • Parts that come in contact with the fluid are corrosion-resistant
  • The installed EC control device ensures easy adjustment and operationally reliability
  • Factory testing and presetting to optimum working range
Series description
Wilo-Economy CO-1 Helix V.../EC

Design

High-efficiency, water-supply unit ready for connection. With vertical stainless steel high-pressure multistage centrifugal pump in glanded version, incl. EC controller (Easy Controller).

Application

  • Fully automatic water supply and pressure boosting in inlet mode, either from the public water supply network or from a tank, for domestic, commercial, industrial and municipal applications (e.g. residential, office, administration buildings, hotels, hospitals, trades, industry, water supply companies).
  • Pumping of drinking water and process water, cooling water, fire water (apart from fire-fighting systems in accordance with DIN 14462 and with the approval of the local fire safety authorities) or other types of industrial water that do not attack the materials either chemically or mechanically and do not contain abrasive or long-fibre constituents.

Equipment/function

  • 1 pump of the Helix V series with IE3 standard motor, including 0.75 kW and larger (optional for smaller motor power)
  • Components that come in contact with the fluid are corrosion-resistant
  • Base frame made of galvanised steel, with height-adjustable oscillation absorbers for insulation against structure-borne noise
  • Shut-off valve, discharge side
  • Non-return valve, discharge side
  • Diaphragm pressure vessel 8 l, PN 16, discharge side
  • Pressure transducer, discharge side
  • Pressure gauge, discharge side
  • Optionally with low-water cut-out switchgear (WMS) with pressure gauge, suction side
  • EC-control with IP54 plastic housing, consisting of an internal power supply unit, microprocessor, analogue and digital input and output modules

Typekey

Example:

Wilo-Economy CO-1 Helix V 1608/K/EC

Economy

Product family: pressure-boosting systems

CO

Series designation

1

Number of pumps

Helix

Pump series name

V

Pump design, vertical

16

Rate volume flow of the pump [m3/h]

08

Number of pump stages

K

With cartridge mechanical seal (for Helix V 22.., V 36.. and V 52..)

EC

Control device (Economy Control)

Technical data

  • Mains connection 3~230/400 V ±10 %, 50 Hz (other versions on request)
  • Max. fluid temperature 50 °C (70 °C optional)
  • Max. ambient temperature of 40 °C
  • Operating pressure 16 bar
  • Inlet pressure 10 bar
  • Switching pressure ratings 6/10/16 bar
  • Nominal connection diameters on the discharge side Rp 1 ¼" - DN 80
  • Nominal connection diameters on the inlet side (DN32) Rp 1 ¼"- DN 80
  • Rated speed 2850 rpm
  • Protection class IP54
  • Switching capacity P2 max. at max. 10 A = 4 kW (for > 4-kW downstream electromechanical power section)
  • Fuse protection on mains side AC 3 according to motor power and EVU regulations
  • Approved fluids (other fluids on request): Note regarding fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents.
    • Pure water without settling sediments
    • Process water, cold water, cooling water and rainwater
    • Drinking water
    • Firefighting water

Materials

Helix V 4 to V 16

  • Impellers, guide vanes, stage housing made of stainless steel 1.4307
  • Pump housing of stainless steel 1.4301
  • Shaft of stainless steel 1.4057
  • 1.4404 shaft protection sleeve
  • O-ring gaskets made of EPDM (FKM gasket on request)
  • Pipework made of 1.4571 stainless steel

Construction

  • Base frame: galvanised steel, with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
  • Pipework: complete pipework made of stainless steel, suitable for the connection of all piping materials used; the pipework is dimensioned according to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 pump of the Helix V 4 to Helix V 52 series; all parts which come into contact with the fluid are made of stainless steel; other versions on request. KTW/WRAS/ACS approval for all parts that come in contact with the fluid.
  • Valves: the pump is fitted on the pressure side with a shut-off device with DVGW approval mark or a shut-off valve with DVGW approval mark and on the pressure side with a KTW-approved non-return valve
  • Diaphragm pressure vessel: 8 l/PN 16 arranged on the discharge side with a diaphragm made of butyl rubber, with DVGW/KTW approval, completely safe in accordance with food safety laws, for testing and inspection purposes, with a shut-off ball cock with drain and throughflow fitting with DVGW/KTW approval in accordance with DIN 4807
  • Pressure sensor: 4 to 20 mA, arranged on the discharge side for controlling the central CE+ controller
  • Pressure indication: pressure gauge (ø 63 mm) arranged on the discharge side; additional digital indication of the discharge pressure on the alphanumeric touchscreen on the Comfort Controller
  • Control device/controller: the system is standard-equipped with a CE+ controller

Scope of delivery

  • Factory-mounted, ready for connection pressure boosting system checked for functionality and impermeability
  • Installation and operating instructions

Options

Other mains connections on request

Consulting guide

Low-water cut-out

The Economy controller CE+ is intended for low-water cut-out sensors such as pressure switches and float switches. As well as being combined with these sensors, which are usually arranged on the intake side, it can also be fitted on the pressure side. The contacts of the required sensors must be wired to line-up terminals in the control device. The low water cut-out switchgear sensor is to be ordered separately.

Inlet pressure

The maximum inlet pressure (see Technical data) is to be observed for the system configuration. The maximum inlet pressure is calculated from the maximum system operating pressure minus the maximum pump delivery head at Q = 0.

Pressure reducer

Excessively high or a heavily fluctuating inlet pressure will require the installation of a pressure reducer to maintain a constant minimum inlet pressure level. Permitted inlet pressure fluctuation max. 1.0 bar

Only for fire protection systems

Version in accordance with DIN 1988 (EN 806), part 6

This does not apply to fire-extinguishing systems in accordance with DIN 14462. Please request these separately.

Always observe the specifications in DIN 1988 (EN 806) when using and operating the pressure boosting system.

Documents

Installation and operating instructions

Wilo-Helix V, .. FIRST V, ..2.0-VE 2-4-6-10-16

Article Number 4143727
Edition 2023-03
Number of pages 24
Language en
PDF (5 MB)

Wilo-Helix V, FIRST V, 2.0-VE 22-36-52

Article Number 4120943
Edition 02/2022
Number of pages 28
Language en
PDF (7 MB)

Wilo-Economy CO-1 ..., CO/T-1 ... .../CE+ .../ER,Wilo-Comfort-Vario COR-1 ... ...-GE .../VR

Article Number 2527299
Edition 2021-07
Number of pages 32
Language en
PDF (4 MB)

Wilo-Control EC/ECe-Booster

Article Number 2549070
Edition 2023-08
Number of pages 56
Language en
PDF (9 MB)

Certificate

Atest PZH Zestawy CO, COR

Number of pages 1
Language language neutral
PDF (369 KB)
Product selection
Product descriptionPipe connection on the suction side DNsPipe connection on the discharge side DNdSystem output without standby pump QMaximum operating pressure PNGross weight, approx. mArticle number
CO-1 Helix V 403/EC
G 1
G 1
6.5 m³/h
16 bar
72 kg
2554833
CO-1 Helix V 404/EC
G 1
G 1
6.5 m³/h
16 bar
73 kg
2554834
CO-1 Helix V 406/EC
G 1
G 1
6.5 m³/h
16 bar
80 kg
2554835
CO-1 Helix V 407/EC
G 1
G 1
6.5 m³/h
16 bar
81 kg
2554836
CO-1 Helix V 409/EC
G 1
G 1
6.5 m³/h
16 bar
82 kg
2554837
CO-1 Helix V 410/EC
G 1
G 1
6.5 m³/h
16 bar
88 kg
2554838
CO-1 Helix V 412/EC
G 1
G 1
6.5 m³/h
16 bar
89 kg
2554839
CO-1 Helix V 414/EC
G 1
G 1
6.5 m³/h
16 bar
106 kg
2554840
CO-1 Helix V 416/EC
G 1
G 1
6.5 m³/h
16 bar
106 kg
2554841
CO-1 Helix V 418/EC
G 1
G 1
6.5 m³/h
16 bar
108 kg
2554842
CO-1 Helix V 603/EC
G 1¼
G 1¼
10 m³/h
16 bar
74 kg
2554843
CO-1 Helix V 604/EC
G 1¼
G 1¼
10 m³/h
16 bar
80 kg
2554844
CO-1 Helix V 605/EC
G 1¼
G 1¼
10 m³/h
16 bar
82 kg
2554845
CO-1 Helix V 606/EC
G 1¼
G 1¼
10 m³/h
16 bar
83 kg
2554846
CO-1 Helix V 607/EC
G 1¼
G 1¼
10 m³/h
16 bar
89 kg
2554847
CO-1 Helix V 608/EC
G 1¼
G 1¼
10 m³/h
16 bar
90 kg
2554848
CO-1 Helix V 609/EC
G 1¼
G 1¼
10 m³/h
16 bar
91 kg
2554849
CO-1 Helix V 610/EC
G 1¼
G 1¼
10 m³/h
16 bar
92 kg
2554850
CO-1 Helix V 611/EC
G 1¼
G 1¼
10 m³/h
16 bar
108 kg
2554851
CO-1 Helix V 612/EC
G 1¼
G 1¼
10 m³/h
16 bar
115 kg
2554852
CO-1 Helix V 613/EC
G 1¼
G 1¼
10 m³/h
16 bar
117 kg
2554853
CO-1 Helix V 614/EC
G 1¼
G 1¼
10 m³/h
16 bar
117 kg
2554854
CO-1 Helix V 615/EC
G 1¼
G 1¼
10 m³/h
16 bar
118 kg
2554855
CO-1 Helix V 616/EC
G 1¼
G 1¼
10 m³/h
16 bar
119 kg
2554856
CO-1 Helix V 1002/EC
G 1½
G 1½
16 m³/h
16 bar
83 kg
2554857
CO-1 Helix V 1003/EC
G 1½
G 1½
16 m³/h
16 bar
84 kg
2554858
CO-1 Helix V 1004/EC
G 1½
G 1½
16 m³/h
16 bar
91 kg
2554859
CO-1 Helix V 1005/EC
G 1½
G 1½
16 m³/h
16 bar
93 kg
2554860
CO-1 Helix V 1006/EC
G 1½
G 1½
16 m³/h
16 bar
94 kg
2554861
CO-1 Helix V 1007/EC
G 1½
G 1½
16 m³/h
16 bar
102 kg
2554862
CO-1 Helix V 1008/EC
G 1½
G 1½
16 m³/h
16 bar
103 kg
2554863
CO-1 Helix V 1009/EC
G 1½
G 1½
16 m³/h
16 bar
118 kg
2554864
CO-1 Helix V 1010/EC
G 1½
G 1½
16 m³/h
16 bar
119 kg
2554865
CO-1 Helix V 1011/EC
G 1½
G 1½
16 m³/h
16 bar
120 kg
2554866
CO-1 Helix V 1012/EC
G 1½
G 1½
16 m³/h
16 bar
150 kg
2554867
CO-1 Helix V 1013/EC
G 1½
G 1½
16 m³/h
16 bar
151 kg
2554868
CO-1 Helix V 1015/EC
G 1½
G 1½
16 m³/h
16 bar
153 kg
2554869
CO-1 Helix V 1603/EC
G 2
G 2
26 m³/h
16 bar
107 kg
2554870
CO-1 Helix V 1604/EC
G 2
G 2
26 m³/h
16 bar
115 kg
2554871
CO-1 Helix V 1605/EC
G 2
G 2
26 m³/h
16 bar
117 kg
2554872
CO-1 Helix V 1606/EC
G 2
G 2
26 m³/h
16 bar
118 kg
2554873
CO-1 Helix V 1607/EC
G 2
G 2
26 m³/h
16 bar
126 kg
2554874
CO-1 Helix V 1608/EC
G 2
G 2
26 m³/h
16 bar
127 kg
2554875
CO-1 Helix V 1609/K/EC
G 2
G 2
26 m³/h
16 bar
172 kg
2554876
CO-1 Helix V 1610/K/EC
G 2
G 2
26 m³/h
16 bar
174 kg
2554877
CO-1 Helix V 1611/K/EC
G 2
G 2
26 m³/h
16 bar
175 kg
2554878