CPA-FS1/2.2 DOL
Technische Daten | |
---|---|
Netzanschluss | 3~380 V, 50/60 Hz |
Min. Nennstrom I | 6,4 A |
Max. Nennstrom pro Pumpe I | 5,4 A |
Einschaltart | Direkt (DOL) |
Steuerung | ohne Frequenzumrichter |
Schutzart | IP54 |
Max. Anzahl ansteuerbarer Pumpen | 1 |
Max. Nennleistung je Pumpenmotor P2 | 2,2 kW |
Phasen | 3 |
Werkstoffe | |
---|---|
Werkstoff Gehäuse | 1.0330/DC01 (CCR Coated) |
Standard: 3~ 380 V, 50/60 Hz
Produktdaten | |
---|---|
Fabrikat | Wilo |
Produktbezeichnung | CPA-FS1/2.2 DOL |
Artikelnummer | 2485439 |
Minimale Bestellmenge | 1 |
Marktverfügbarkeit | 2010-01-01 |
Verpackung | |
---|---|
Verpackungsart | Karton |
Verpackungseigenschaft | Transportverpackung |
Anzahl pro Palette | 1 |
Anzahl pro Layer | 1 |
Maße und Gewichte | |
---|---|
Längenmaß mit Verpackung | 700 mm |
Länge L | 500 mm |
Höhenmaß mit Verpackung | 1000 mm |
Höhe H | 700 mm |
Breitenmaß mit Verpackung | 350 mm |
Breite B | 300 mm |
Gewicht brutto ca. m | 32 kg |
Gewicht netto ca. m | 30 kg |
Operating Principle
• CPA-HS (analogue sensor control): A 4-20 mA level transmitter in the sump sends a continuous signal to the panel PLC. Each pump has its own user-defined start level; the PLC stages pumps in or out to keep the liquid at the programmed minimum level.
• CPA-FS (float switch control): The system operates with a minimum-level float, a maximum-level float, and one auxiliary float per pump. Pumps start and stop sequentially as each float is reached.
• Two selectable modes via the touch-screen HMI
– Mode 0 – Emergency: All pumps start individually at their set level and stop together when the minimum level is reached.
– Mode 1 – Standard: Pumps start individually at their set levels, then stop one-by-one as the water falls; the last running pump stops at the minimum level.
Product Features and Benefits
• Lockable main isolator and Hand-0-Auto selector for every pump
• Phase-failure relay and emergency stop for enhanced safety
• Automatic duty rotation and instant standby takeover on pump fault
• Touch-screen display shows all set-points, levels and pump status; operating hours can be reset per pump
• Adjustable start/stop delays and individual run / rest timers for each pump
• Built-in self-test (auto test) and service hour counter for preventive maintenance
• Two-mode operation (Emergency / Standard) adapts to site priorities
• HS version: accepts 4-20 mA analogue level input
• FS version: accepts float-switch inputs
• IP54 powder-coated steel enclosure withstands humid underground chambers
• Digital multimeter on the front panel displays voltage, current and frequency in real time
• Moisture (leak) sensor & PTC thermistor relay inputs for every motor
Technische Daten | |
---|---|
Max. Anzahl ansteuerbarer Pumpen | 1 |
Phasen | 3 |
Nennspannung U | 380 V |
Netzfrequenz f |
|
Min. Nennstrom I | 6,4 A |
Max. Nennstrom pro Pumpe I | 5,4 A |
Einschaltart | Direkt (DOL) |
Schutzart | IP54 |
Werkstoff Gehäuse | 1.0330/DC01 (CCR Coated) |
Länge L | 500 mm |
Breite W | 300 mm |
Höhe H | 700 mm |
Gewicht netto ca. | 30 kg |
Fabrikat | Wilo |
Art.-Nr. | 2485439 |