Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
CronoBloc-BL 65/125-1,1/4 | Wilo

CronoBloc-BL 65/125-1,1/4

Article number : 9132647
Replacement recommendation
Number of results: 1


Product design type Glanded monobloc pumpExisting pump
Description
Product description CronoBloc-BL 65/125-1,1/4
Article number 9132647
Series -
Mains connection 3~400 V ±10%, 50 Hz3~400 V ±10%, 50 Hz
Pump connection DN 80DN 80
Comment Check the pipe connection-
Motor data
Materials
Pipe connection
Dimension, weight
Ordering information
Technical data
Hydraulic data
Minimum efficiency index (MEI) ≥0,4
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 140 °C
Max. ambient temperature Tmax 40 °C
Maximum operating pressure PN 16 bar
Note on dimensioning 16 bar to 120 °C, 13 bar to 140 °C
Motor data
Mains connection 3~400 V, 50 Hz
Number of poles 4
Voltage tolerance ±10 %
Motor efficiency class IE3
Rated power P2 1,1 kW
Rated current IN 2,6 A
Rated speed n 1450 1/min
Power factor cos φ100 0,75
Motor efficiency 50% ηM 50% 80,1 %
Motor efficiency 75% ηM 75% 82,7 %
Motor efficiency 100% ηM 100% 84,1 %
Motor winding up to 3 kW -
Motor winding from 4 kW -
Insulation class F
Protection class motor IP55
Motor protection no
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Grey cast iron EN-GJL-200
Impeller (optional) CC480K (G-CuSn10) Bronze
Shaft Stainless steel
Mechanical seal AQ1EGG
Installation dimensions
Pipe connection on the suction side DNs DN 80
Pipe connection on the discharge side DNd DN 65

CronoBloc-BL 65/125-1,1/4

∆: Connection diagram delta connection

Y: Connection diagram star connection

Motor protection switch required on-site. Check the direction of rotation! To change the direction of rotation, exchange any two phases.

P2≤ 3 kW 3~400 V Y
  3~230 V ∆
P2≥ 4 kW 3~690 V Y
  3~400 V ∆

After removing the bridges, Y-∆ start is possible.

Airborne sound data sheet

Airborne sound power LW,A
Octave band centre frequency in Hz Level in dB(A), ref. 20µPa
L63 29,8
L125 42,3
L250 50,8
L500 57,8
L1000 64
L2000 67,6
L4000 60,5
L8000 51,4
Airborne sound-power level (total) Lw 70 db(A)
Airborne sound pressure Lp,A,1m
Octave band centre frequency in Hz Level in dB(A), ref. 1pW
L63 17,8
L125 30,3
L250 38,8
L500 45,8
L1000 52
L2000 55,6
L4000 48,5
L8000 39,4
Airborne sound-pressure level (total) Lp 58 db(A)
The acoustic values given are based on measurements and in some cases on calculations and may deviate by up to 3 dB.
Documents

Installation and operating instructions

Wilo-Wilo-CronoLine-IL Wilo-CronoTwin-DL Wilo-CronoBloc-BL

Article Number 2202024
Edition 2018-07
Number of pages 128
Language de, en, fr, nl
PDF (12 MB)

Wilo-Atmos GIGA-I/-D/-B

Article Number 2230376
Edition 2024-09
Number of pages 72
Language en, zh
PDF (7 MB)

Consulting guide

Glanded pumps, single-stage, single-volute

Edition 2021-12
Number of pages 24
Language en
PDF (7 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (287 KB)

Standard Conformity

Standard Conformity 2215997-01

Number of pages 1
Language language neutral
PDF (141 KB)
BIM/CAD

3D_DWG

BL65/125-1,1/4

Language language neutral
DWG (887 KB)

3D_STEP

BL65/125-1,1/4

Language language neutral
STP (1 MB)

2D_DWG_TOP

BL65/125-1,1/4

Language language neutral
DWG (19 KB)

2D_DWG_FRONT

BL65/125-1,1/4

Language language neutral
DWG (19 KB)

2D_DWG_RIGHT

BL65/125-1,1/4

Language language neutral
DWG (17 KB)

Take advantage of the latest replacement guide

The current replacement guide on all glandless pumps for heating and drinking water applications makes choosing the right pump easier for you. Here, you will find a suitable new Wilo pump for all known pumps built after 1975.

After entering your old pump data, select the current pump type.