SiFire EN N 32/250-257-30 E

Article number : 4208287
Technical data
Hydraulic data
Maximum inlet pressure p inl 6 bar
Maximum operating pressure PN 10 bar
Number of pumps 1
Min. fluid temperature Tmin 3 °C
Max. fluid temperature Tmax 25 °C
Min. ambient temperature Tmin 4 °C
Max. ambient temperature Tmax 40 °C
Motor data
Mains connection 3~400 V, 50 Hz
Rated power P2 30 kW
Rated current IN 52.7 A
Power factor cos φ100 0.88
Rated speed n 2955 1/min
Protection class switchgear IP54
Materials
Pipework material Steel
Installation dimensions
Pipe connection on the suction side DNs DN 50
Pipe connection on the discharge side DNd DN 65
Product data
Brand Wilo
Product description SiFire EN N 32/250-257-30 E
Article number 4208287
EAN number 4048482673608
Colour Red/black/silver
Minimum order quantity 1
Date of sales availability 2016-09-01
Packaging
Packaging type Special pallet
Packaging property Sales packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 944 mm
Length L 744 mm
Height with packaging 1620 mm
Height H 1490 mm
Width with packaging 2296 mm
Width W 2096 mm
Gross weight, approx. m 721 kg
Net weight, approx. m 671 kg
Tender text

Pressure boosting system as a fully automatic compact unit for fire fighting purposes in accordance with EN 12845 and equipment for the Nordic regions.

Consisting of a pump with horizontal base frame - EN 733 - with spacer coupling, electric motor and diaphragm pressure vessel (capacity: 20 l) and one switch cabinet, fixed to a robust support structure.

Model SC-Fire E for the electric motor, equipped with Smart Controller, solid construction made of special profiled parts with cut-outs for forklift trucks and hooks to ensure trouble-free, safe transportation. Height-adjustable bracket for the outlet manifold and special base frame which reduces the transfer of vibrations considerably and increases the reliability and service life.

A circuit with dual pressure switch, pressure gauge, non-return valve, valve (with position switch secured from use by unauthorised personnel) for the main pump for automatic start. The cables are concealed in the construction and protected against bumps and cuts. Equipped with a diaphragm installed directly on the main pump housing as standard, to prevent overheating in the event of zero flow.

SC-Fire E switchgear for fire extinguishing systems according to EN 12845.

Switchgear integrated in a sheet metal enclosure in accordance with protection class IP54.

Optimum regulation and ease of use by SC-Fire control with symbol-based LC display, easy user interface with simple menu navigation, push buttons and rotary knob for quick setting of parameters. Communicative control unit for monitoring system operation.

The system has been mounted on the base frame with wires and pipes are ready for connection.

Inlet pressure:

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum delivery head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For the main pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 750 m³/h (208 l/s) system configuration for the main pump.

Switchgear/control device for fire water supply systems

Wilo-Control SC-Fire E (main pump with electric motor)

Hardware:

Fully electronic central control unit, installed in a painted steel enclosure, protection class IP54, control and display devices on the front door

Features and functions:

The design of the control device depends on the power of the connected pump (start via DOL or star-delta connection). The device comprises the following components:

  • Main switch: For switching the switchgear on and off. (For unauthorised use in the event of a fire)
  • Display: Display built into the door of the switch cabinet for operation and display purposes. Shows the operating data and the operating status of the pump and the control unit using a combination of symbols and number codes. Menus are selected and parameters entered with the red push button.
  • Microprocessor: Microprocessor PLC realised by programming, power supply unit and I/O wiring. The configuration of the programming depends on the system and the sprinkler system
  • Indicators: Long-life signal lamps indicate the operational readiness and operation of the pump, the activation of the pressure switch and float switch, a false start, a collective error as well as manual start and manual stop
  • Buttons: Push buttons for manual start and manual stop, the lamp test and acknowledgement of alarms and warning messages
  • Fuse protection: Fuses which tolerate the starting current for at least 20 s
  • Motor startup: Contactor for direct-on-line starting, up to 22 kW, for higher power levels start via star-delta connection
  • Motor protection: Only for signalling
  • Monitoring of the water supply: By means of a float switch to ensure a minimum water level of 2/3 of the supply tank is always maintained
  • Performance monitoring: Power supply and performance of the pump
  • Combined signal report: All types of error are displayed via a common error indicator
  • Individual signal report: The important false start error message is displayed via an individual error indicator
  • Error message and acknowledgement: All error messages are displayed via LEDs, shown in the display as an error code and must be acknowledged

Software:

  • Factory-programmed for fully automatic operation
  • Information regarding voltage, electric current and power of the pump
  • Menu navigation with plain text display (symbol representation)

Conforms to the following standards:

  • Fixed firefighting systems - Automatic sprinkler systems (EN 12845), part for pumps with electric motor
  • Electrical equipment of machines (EN 60204-1)
  • Low-voltage switchgear and controlgear assemblies (EN 61439-1 and EN 61439-2)
  • Electromagnetic compatibility (EMC) — Immunity for industrial environments (EN 61000-6-2)
  • Electromagnetic compatibility (EMC) — Emission standard for residential, commercial and light-industrial environments (EN 61000-6-3)

Function description:

Wilo SC-Fire E control devices can be used to control pumps with an electric motor, sensors for pump management and the level of information. The microprocessor-controlled switchgear is used to control and regulate all required functions of a pressure boosting system according to EN 12845, for test purposes or actual sprinkler events.

The operating logic for the fire extinguishing system is based on the cascade calibration of the pressure switches for starting the pump.

If a large amount of water is requested due to the opening of one or more circuits or due to a defective sprinkler, the pressure in the system decreases. As a result, the main pump is started using switchgear. If the electric main pump does not start in systems with multiple pumps (for example due to problems with the power supply), a pressure drop will activate the pressure switch of the standby pump, which starts this pump. In some cases, two or more electric pumps can be used.

As soon as the sprinkler circuit or gate valve, via which the sprinkler heads are supplied, is closed, pressure is built up in the system. The stop buttons on the front door must then be pressed to stop the pump.

Operating Data
Max. delivery head Hmax 91.8 m
Number of pumps 1
Fluid temperature T 3 °C
Ambient temperature T 4 °C
Maximum operating pressure PN 10 bar
Maximum inlet pressure p inl 6 bar
Motor data
Mains connection 3~400 V, 50 Hz
Rated power P2 30 kW
Rated current IN 52.7 A
Power factor cos φ100 0.88
Rated speed n 2955 1/min
Protection class switchgear IP54
Materials
Shaft seal BVEGG
Pipework material Steel
Installation dimensions
Pipe connection on the suction side DNs DN 50
Pipe connection on the discharge side DNd DN 65
Ordering information
Brand Wilo
Product description SiFire EN N 32/250-257-30 E
Net weight, approx. m 671 kg
Article number 4208287
Documents

Installation and operating instructions

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 148
Language en, mk, no, sr, uk
PDF (6 MB)

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 13
Language en
PDF (1 MB)

Wilo-SiFire EN Nordic

Article Number 4210261
Edition 1604
Number of pages 1
Language bg, cs, de, el, en, es, et, fr, hr, hu, it, lt, lv, mk, nl, pl, pt, ro, ru, sk, sl, sr, tr, uk
ZIP (28 MB)

Wilo-Control SC-Fire Diesel

Article Number 2541367
Edition 1510
Number of pages 1
Language en, mk
ZIP (39 MB)

Wilo-Control SC-Fire Diesel

Article Number 2541367
Edition 1510
Number of pages 34
Language en
PDF (1 MB)

Wilo-Control SC-Fire Electric

Article Number 2539954, 2541365, 2541366
Edition 1510
Number of pages 1
Language en, mk
ZIP (31 MB)

Wilo-Control SC-Fire Electric

Article Number 2539954, 2541365, 2541366
Edition 1510
Number of pages 31
Language en
PDF (1 MB)

Wilo-Control SC-Fire Electric

Article Number 2539954, 2541365, 2541366
Edition 1510
Number of pages 32
Language en
PDF (2 MB)
Article Number 2541363
Number of pages 1
Language en, mk
ZIP (12 MB)

Wilo-Control SC-Fire Jockey

Number of pages 10
Language en
PDF (727 KB)

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Number of pages 451
Language ar, bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, lt, lv, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk
PDF (18 MB)

Wilo-Medana CV1-L

Article Number 4245263
Edition 03/2021
Number of pages 196
Language da, de, en, es, fi, fr, it, nl, no, pl, ru, sv, tr, uk
PDF (6 MB)

Wilo WNF-S

Article Number 2145711
Edition 2014-01
Number of pages 132
Language de, en, fr, nl
PDF (9 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral