Your advantages

  • Reliable control and monitoring of one or two pumps, thanks to various monitoring and alarm functions
  • Flexible level measurement with level sensor, dynamic pressure bell or float switches
  • Increased plant safety when controlling pumps in explosive areas by extending the monitoring functionality in Ex-mode (hardware and software)
  • Easy operation with alphanumeric, symbol-based menu and red-button technology
  • Operating statuses can be viewed at any time. Greater ease of use via integration with remote monitoring systems via Modbus or optionally via GSM
  • Flexible installation. Universal power supply for single-phase current and three-phase current and a wide operating temperature range of -30 °C to + 60 °C
  • Universal use for water supply and sewage disposal – also in potentially-explosive areas
  • Advanced system control with individual operation and fault signal, optionally also in the event of power failure
  • Additional operational safety thanks to separate level recording for high water and dry-running protection

Equipment/function

Functions

  • Two different operating modes for a broad field of application:
    • “Drain” operating mode: For draining sewage chambers
    • “Fill” operating mode: For filling water tanks and rainwater storage tanks
  • Configurable overload protection
  • Thermal motor monitoring
  • Pump kick function
  • Adjustable follow-up time
  • Automatic pump alteration (for switchgear for 2 or 3 pumps)
  • Service life optimisation (for switchgear for 2 or 3 pumps)
  • Standby pump (for switchgear for 2 or 3 pumps)
  • Automatic fault-actuated switchover (for switchgear for 2 or 3 pumps)
  • Direction of rotation monitoring
  • High water alarm with forced switch-on of the connected pump(s)
  • Dry-running protection
  • Fault memory for 10 error messages including the type of fault

Equipment

  • Display of the current operating status and data, as well as faults via the LCD display and LEDs
  • Symbol-based menu navigation
  • Configuration of operating parameters and operation via operating button
  • Main switch (depending on version)
  • Remote access via ModBus
  • Integrated alarm buzzer
  • Operating mode “Ex” for loading presets for “Ex” applications

Type key

Example:

Wilo-Control EC-L 1x12A-T34-DOL-WM-EMS-IPS

Control

Switchgear

EC

Easy control series

L

“Lift” version for water lifting applications

1

Number of pumps that can be connected

12 A

Maximum rated current per pump

T34

Mains connection: M = 1~220–230 V, 50/60 Hz T4 = 3~380–400 V, 50/60 Hz 34 = live wire voltage, e.g. 380–400 V

DOL

Starting mode: Direct activation

WM

Installation type: Wall installation

EMS

Without main switch

IPS

Internal pressure sensor for direct connection of an immersion bell

Technical data

  • Mains connection: 1~220-230 V, 50/60 Hz or 3~380-400 V, 50/60 Hz
  • Max. rated power (P2) per pump: 4 kW
  • Maximum rated current IN per pump: 12 A
  • Activation type of connected pumps: Direct
  • Control voltage: 24 V DC
  • Ambient/operating temperature: -30…+50 °C
  • Storage temperature: -30…+60 °C
  • Max. relative humidity: 90 %, non-condensing
  • Housing material: Polycarbonate, UV-resistant
  • Protection class: IP54
  • Electrical safety: Pollution degree II

Description/construction

Microcontroller-controlled switchgear for level-dependent control of two or three submersible pumps with analogue or digital signal transmitters. Individual parameters are entered via symbol-based menu navigation and an operating button.

Inputs

  • 1x analogue precision input 4 – 20 mA for level control with level sensor to control 1 to 3 pumps
  • 2x (for 1 pump) or 3x (for 2 pumps) digital inputs for level control with float switch
  • 1x digital input for low water level with float switch (dry-running protection)
  • 1x digital input for high water signal with float switch (high water alarm)
  • 1x input for level control with an immersion bell (“IPS” version only)
  • 1x ... 3x inputs* for thermal winding monitoring with bimetallic temperature sensor. Connection of PTC sensors is not possible!
  • 1x ... 3x inputs* for connecting moisture sensors (e.g. motor compartment leakage or sealing chamber monitoring)
  • 1x digital input for External On/Off for remote activation and deactivation of automatic mode

Outputs

  • 1x potential-free contact for the collective run signal (SBM)
  • 1x potential-free contact for the collective fault signal (SSM)
  • 1x potential-free contact for the individual run signal (EBM) per pump
  • 1x potential-free contact for the individual fault signal (ESM) per pump
  • 1x analogue output 0-10 V for the output of the actual level value

*Depending on the number of pumps that can be connected.

Series

Control EC-L

Downloads

REACH regulation

Edition 2018-10
Page format 209.9 x 296.7 mm
Number of pages 4

PDF (581 kB)

Download

Wilo-Control EC-L

Article Number 2543252
Edition 2018-12
Version number 03/SW: 2.01xx
Page format 209.9 x 297.0 mm
Number of pages 264

PDF (6 MB)

Download

Product

PDF: Control EC-L

Configure

Page selection

Format selection

Optional information

You can enter any personal information that you want to be displayed in the header.

Download