Article number: 4240870
Technical data
Hydraulic data
Maximum operating pressure PN 12 bar
Number of pumps 2
Min. fluid temperature Tmin 4 °C
Max. fluid temperature Tmax 25 °C
Min. ambient temperature Tmin 4 °C
Max. ambient temperature Tmax 40 °C
Motor data
Protection class switchgear IP54
Diesel engine
Air volume flow cooling 1578 m³/h
Cooling method Air
Cylinder capacity 1.248 l
Cylinder number 2
Rated power 17500 W
Rated speed 2900 1/min
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Bronze
Shaft Stainless steel
Gasket material EPDM
Pipework material Steel
Installation dimensions
Pipe connection on the suction side DNs DN 50
Pipe connection on the discharge side DNd DN 50

SiFire DJ

Dimensions H 1234 mm
Dimensions H1 1152 mm
Dimensions H2 410 mm
Dimensions P 745 mm
Dimensions HS 760 mm
Dimensions LS 760 mm
Pipe connection on the discharge side DNd DN 50
Pipe connection on the discharge side DNd PN 16
Pipe connection on the suction side DNs DN 50
Pipe connection on the suction side DNs PN 16
Dimensions L 1748 mm
Dimensions T 204 mm
Dimensions TS 210 mm
Dimensions HB 1472 mm
Dimensions w1 284 mm
Dimensions w2 349 mm
Product data
Brand Wilo
Product description SiFire-FIRST-32/250-262-17,7DJ
Article number 4240870
EAN number 4062679049748
Colour Red/black/silver
Minimum order quantity 1
Date of sales availability 2020-09-01
Packaging
Packaging type One-way pallet
Packaging property Sales packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 945 mm
Length L 745 mm
Height with packaging 1602 mm
Height H 1472 mm
Width with packaging 1948 mm
Width W 1748 mm
Gross weight, approx. m 540 kg
Net weight, approx. m 490 kg
Tender text

Pressure boosting system as a fully automatic compact unit for firefighting purposes in accordance with EN 12845.

Consisting of a main pump with horizontal base frame - EN 733 - with spacer coupling (up to 17,7kW) or cardanic joint (above 17,7kW) joint, diesel motor and multistage vertical electric jockey pump, and one switch cabinet per pump, fixed to a robust support structure.

Model D for the diesel motor, equipped with firefighting dedicated controller, plus an electronic device J for jockey pump, solid construction made of special profiled parts with cut-outs for forklift trucks and hooks to ensure trouble-free, safe transportation.

A circuit with dual pressure switch, pressure gauge, non-return valve, valve (secured from use by unauthorized personnel) for the main pump for automatic start. Equipped with a diaphragm installed directly on the main pump housing as standard, to prevent overheating in the event of zero flow.

Separated fuel tank with level sensor and adequate volume to allow 6 hours operating autonomy and 2 batteries on the base plate and battery chargers in the control box.

Switchgears D and J for fire extinguishing systems in accordance with EN 12845.

Switchgear D integrated in a sheet metal enclosure in accordance with protection class IP54.

Electronic device J built in a compact case, protection class IP65.

Very high control quality and very simple operation due to the firefighting dedicated controller, with multi-languages screen, easy navigation with simple menu and push button plus immediate operation status with symbols. Communication-ready controller for supervising systems operations.

The system has been mounted on the base frame with wires and pipes are ready for connection.

Inlet pressure:

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum delivery head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For the main pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 320 m³/h (89 l/s) system configuration for the main pump.

Switchgear/control device for fire water supply systems

Wilo-Control D (main pump with diesel motor)

Hardware:

Fully electronic central control unit, built in painted steel case, with protection class IP 54, control and display devices on the front door.

Features and functions:

The controller design is suitable for the performance of each motor-pump combination. The device comprises the following components:

Main switch: For switching the switchgear On/Off. (Unauthorized action in case of fire).

Display: Back lighted graphic LCD display, built into the switch cabinet door for operating and display purposes. Displays the operating data and the receptive current operating statuses of pump and the controller. The menu selection as well as the parameter input are done by push buttons on the front door.

Microprocessor: Integrated PLC logic with thresholds, counters, alarms, status; 12 VAC auxiliary power supply; advanced I/O wired functions. The respective programming configuration is strictly dependent on system and sprinkler installation.

Indicators: Long-life indicator lights to show, power supply status, pump running, motor status, pressure switch on, battery status, battery selection, automatic mode excluded, manual reset, alarm stop.

Buttons: Push button to manage manual stop, manual start battery A, manual start battery B, manual test mode, alarm reset and menu selection.

Fuse protection: Protection fuses for auxiliary contacts and battery charger.

Motor startup: Automatically via two alternating batteries or directly on each battery with start button on the front panel.

Motor protection: Monitoring of typical operating parameters of diesel engine (Temperature, oil pressure, fuel level, and so on) without stop.

Priming tank monitoring: By float switch to keep the water level at minimum 2/3 of the priming tank.

Power monitoring: Speed monitoring of diesel engine.

Battery monitoring: Monitoring of charge voltage, charge current and failure of charger.

Monitoring and controlling: Power supply, engine cooling temperature and oil pressure, analog sensors pressure and temperature, fuel level, batteries voltage, working hours of the engine, pump status, alarm status, pump statistics and starts, Jockey pump starts (if available), maintenance program, pump room temperature and ventilation.

Fault message and acknowledgment: All alarm messages are displayed via LEDs or the graphic LCD. The LEDs color and alarm code must be acknowledged.

Software:

  • Factory-programmed for fully automatic operation
  • Information regarding motor speed, charging voltage and charging current.
  • Menu navigation with text on display

Conforms to the following standards:

  • Fixed automatic Sprinkler Systems - (EN 12845), part for pumps with diesel motor
  • Electrical equipment of machines (EN 60204-1)
  • Low-voltage switchgear and control gear assemblies (EN 61439-1 and EN 61439-2)
  • Electromagnetic compatibility (EMC) — Immunity for industrial environments (EN 61000-6-2)
  • Electromagnetic compatibility (EMC) — Emission standard for residential, commercial and light-industrial environments (EN 61000-6-3)

Function description:

Wilo D control devices can be used to control pumps with a diesel motor, sensors for pump management and the level of information. The microprocessor-controlled switchgear is used to control and regulate all required functions of a pressure boosting system according to EN 12845, for test purposes or actual sprinkler events.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

If a large amount of water is requested due to the opening of one or more circuits or due to a defective sprinkler, the pressure in the system decreases. As a result, the main pump is started using switchgear. If the diesel main pump does not start in systems with multiple pumps (for example due to problems with the power supply), a pressure drop will activate the pressure switch of the standby pump, which starts this pump. In some cases, two or more diesel pumps can be used.

As soon as the sprinkler circuit or gate valve, via which the sprinkler heads are supplied, is closed, pressure is built up in the system. The stop buttons on the front door must then be pressed to stop the pump.

Wilo-Control J (jockey pump with electric motor)

Hardware:

Electronic control device for single phase electric pump, built in a compact case, protection class IP65, control and display devices on the front.

Features and functions:

The design of the controller is dependent on the performance of the connected pump. The device consists of several components:

Main switch: For switching the control device on and off

Display: Digital display for pressure and errors visualization. Intuitive menu selection with push buttons for menu selection and setup on the front.

Indicators: Long-life indicator lights to show power on, pump running and collective fault.

Buttons: Push button to manage menu access and reset, menu scrolling up and manual start, menu scrolling down and current visualization.

Motor protection: short-circuits and over current

Fault message and acknowledgement: All alarm messages are displayed via LEDs or the graphic screen. The LEDs color and alarm code must be acknowledged.

Software:

  • Factory-programmed for fully automatic operation

Conforms to the following standards:

  • Fixed Firefighting Systems - Automatic Sprinkler Systems - (EN 12845), part for jockey pumps
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Control gear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC - Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC - Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo J control devices can be used to control jockey pumps with single phase electric motor according to EN 12845, for test purposes and operation of the sprinkler system.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

The jockey pump of pressure boosting is the first to start and maintains the system full of water and under pressure. It starts when the pressure drops in the system. Start and stop control is set up via the pressure setting menu.

Operating Data
Max. delivery head Hmax 88.7 m
Number of pumps 2
Fluid temperature T 4 °C
Ambient temperature T 4 °C
Maximum operating pressure PN 12 bar
Motor data
Protection class switchgear IP54
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Bronze
Shaft Stainless steel
Shaft seal BVEGG
Gasket material EPDM
Pipework material Steel
Installation dimensions
Pipe connection on the suction side DNs DN 50
Pipe connection on the discharge side DNd DN 50
Ordering information
Brand Wilo
Product description SiFire-FIRST-32/250-262-17,7DJ
Net weight, approx. m 490 kg
Article number 4240870
Documents

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (327 KB)
Accessory

Break tank (1)

Fittings (8)

Motor cooling (3)

Noise control (6)

Pipe installation (8)

Valves/accessories (1)

Alarm signal (1)

Operating/service units (1)

Maintenance/replacement (15)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Maintenance
Maintenance COMFORT SiFire DJ
    
2219505

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance PREMIUM SiFire DJ
    
2219558

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Includes wearing parts

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Commissioning
Commissioning SiFire DJ
    
2219403

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

More suitable services

Service packages
Service Package L SiFire DJ
    
2219488

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package L includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • Energy Solutions
  • WiloCare Premium
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Repairs
  • Extended Warranty
Service Package M SiFire DJ
    
2219484

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package M includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • WiloCare Comfort
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Energy Solutions
  • Repairs
  • Extended Warranty
Service Package S SiFire DJ
    
2219479

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package S includes:

  • Installation check
  • Commissioning
  • Maintenance
  • WiloCare Basic
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Energy Solutions
  • Supervision
  • Repairs
  • Extended Warranty
Wilo-Live Assistant
Wilo-Live Assistant Service
    
2216415

The Wilo-Live Assistant is a technical advisor at your side during pump service. By using the Wilo-Live Assistant, our expert advisers can support you in the boiler or equipment room via video transmission – live and in real time. You use your smartphone to show the installation set-up, while the Wilo expert follows everything on their screen. They can see the components as well as other details and can thus determine where the fault or breakdown originates. We prevent downtime and ensure operational reliability of your pumps and systems!

The Wilo-Live Assistant includes:

  • Interactive live support via video chat
  • Direct contact with an expert
  • Just-in-time solution to ensure maximum operational reliability of your pumps and systems
Extended Warranty
Extended Warranty SiFire DJ
    
2219462

In combination of a new pump or system Wilo offers an extended warranty of up to five years in combination with commissioning and maintenance by the Wilo Service.

Extended warranty includes:

  • Full protection and predictable cost security
  • Regular maintenance work by the Wilo Service
Supervision
Supervision SiFire DJ
    
2219339

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation SiFire DJ
    
2219374

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
System Optimisation
System Optimisation SiFire DJ
    
2219269

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions SiFire DJ
    
2219304

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair SiFire DJ
    
2219474

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report