Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-SiFire FIRST | Wilo

Wilo-SiFire FIRST

A modular design for a wide field of applications.

Your advantages
Wilo-SiFire FIRST D

A modular design for a wide field of applications.

The Wilo-SiFire FIRST is a flexible modular norm pump system in accordance with EN 12845. It could be equipped with electric or diesel motor and jockey pump for a wide field of applications. The compact system is fixed on an universal baseplate which makes the transport, installation and maintenance very easy. The robust design enables a long lifetime.


Your advantages

  • Modular standard pump system with electric or diesel motor for a wide field of applications and high flexibility in designing
  • Long service life thanks to robust design
  • Easy transport, installation and maintenance thanks to an universal baseplate
  • Intuitive handling on specific firefighting switchgear
  • Equipment and pipes calibrated in accordance with EN 12845 standard
  • Quick installation thanks to preinstalled hydraulic and electric components on the discharge side
Series description
Wilo-SiFire FIRST

Design

Pressure-boosting systems for firefighting in accordance with EN 12845.

Depending on the model, composed of 1 horizontal base plate pump – EN 733 – with spacer coupling or cardanic joint, electrical or diesel motor and electrical multistage vertical jockey pump.

Application

Fully automatic water supply for fire-fighting systems with sprinklers in residential, commercial and public buildings, hotels, hospitals, department stores, and for office or industrial buildings.

Equipment/function

  • 1 horizontal base plate pump per system from 32-200 to 100-200 series, with IE3 equivalent standard motor or diesel engine.
  • Diaphragm, to avoid over heating at zero flow, directly installed on the main pump housing.
  • Jockey pump from Medana CV1-L series
  • One controller fixed on robust supports. Model E for electric motor and D for diesel engine, both equipped with a firefighing dedicated controller, plus additional control J for jockey pump, if present.
  • Electro galvanised steel base frame.
  • Pipe work made of steel and epoxy painted. Manifold with flanges.
  • Shut-off butterfly valve with security lock on discharge side of each pump.
  • Non-return valve, on discharge side of each pump.
  • One circuit with double pressure switch, manometer, non return valve, valve, for main pump for automatic start.
  • Concentric cone on discharge side on main pump, for speed limitation according to prameters requested in EN 12845 standard.
  • Connection DN 2" for the priming tank per pump.
  • Pressure gauge on discharge side.
  • Only for diesel engine model:
    • 2 batteries on the base plate and battery chargers in the control box.
    • Separated fuel tank with level sensor and adequate volume to allow 6 hours operating autonomy.
  • Accessories on request:
    • Horizontal priming tank 500 L, with floating valve and pressure switch for low level alarm.
    • Flow meter
    • Kit eccentric cone on suction side complete of butterfly valve with hand lever or hand wheel.
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Antivibration sleeve for manifold
    • Remote panel to transfer alarms level A+B
    • Densimeter for battery
    • Spare part kit for diesel engine
    • Silencer (30 dBA) for diesel engine
    • Hydraulic heat exchanger for diesel engine

Typekey

Example:

Wilo-SiFire FIRST 40/200-180-7.5 EJ

SiFire

Compact pressure-boosting system for firefighting applications in accordance with the EN 12845 standard

FIRST

Optimised functionalities

40/200

Type of main pump

180

DN nominal impeller diameter of the main pump

7.5

Power of the electric motor [kW] *

EJ

Configuration

E

1 electric pump

D

1 diesel pump

J

1 jockey pump

* = minimum motor power, do not fall below

Technical data

Allowed fluid:

  • Non-aggressive clean water, free of abrasive or long fiber substances

Application field:

  • Power supply 3~400 V, 50 Hz (1~230 V, 50 Hz for Jockey pump and Diesel pump control panel)
  • Fluid temperature max. +25 °C
  • Ambiant temperature min/max. +4 to +40 °C (+10 to +40 °C if diesel pump is installed)
  • Maximum operating pressure 16 bar (12 bar with Jockey pump)
  • Maximum inlet pressure 6 bar
  • Flow from 10 to 320 m³/h
  • Maximum head 95 m

Pump impellers:

  • Bronze for main horizontal base plate pump
  • Stainless steel for vertical multistage jockey pump

Electrical Motor:

  • IE3 standard motors
  • Maximum power 55 kW
  • Nominal speed 2900 rpm
  • Protection class IP55

Diesel engine:

  • Direct injection or supercharged diesel motor with air or water cooling.
  • Maximum power 66 kW
  • Forced lubrification with gear pump and oil filter
  • Cooling depending on the power: Up to 17,7 kW with air flow, direct or with water in closed circuit with radiator. From 26,5 kW with heat exchanger water/water.

Other:

  • Epoxy painted pipes and hydraulic connections
  • Discharge nominal connection diameters DN 50 until DN 150 - EN 1092, PN 16
  • Suction nominal connection diameters DN 50 until DN 125 - EN 1092, PN 16
  • Protection class for Control box: IP54

Materials

For horizontal base plate pump

  • Impellers made of Bronze CuSn10 or CuAl10Fe5Ni5
  • Wear rings made of AISI316L/1.4409 stainless steel
  • Pump housing made of cast iron EN-GJL-250
  • Shaft made of AISI420/1.4021 stainless steel

For Jockey pump

  • Impellers made of AISI304/1.4301 stainless steel
  • Pump housing made of AISI304/1.4301 stainless steel
  • Shaft made of AISI304/1.4301 stainless steel
  • O-ring-seals made of EPDM

Construction

  • Base frame: Made of electro galvanised steel profiles, provided with brakets for control boxes. On the bottom part, special rectangular holes for forklift and integrated hooks for lifting straps.
  • Pipe work: Complete pipe work with flanges made of epoxy painted steel, suitable for connection of all commonly used piping materials; the pipe work is sized corresponding to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 horizontal base plate pump – EN 733 – with spacer coupling, electrical or diesel motor. Back pull out model for easy access to pump internal components without moving motor or pipes.
  • Fittings: For main pump, each pump is fitted on discharge side with a butterfly valve and non return valve, both with epoxy painted and adapted for flanged connection.
  • Tank: Separated fuel tank made of epoxy painted steel with leackage bacin.
  • Sensors and display: 2 Pressure switch 2/16 bar per pump located on the discharge side for activating the pump start through the control box controller. Discharge-side pressure gauge (ø 63 mm) located close to the pressure switches.
  • Control device/controller: The system is standard-equipped with control box for electric or diesel motor and a jockey pump controller, if present.

Scope of delivery

  • Factory-mounted, ready-for-installation pressure-boosting system, which has been checked for functionality and impermeability
  • Installation and operating instructions
  • Required accessories on request
Documents

Installation and operating instructions

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Number of pages 451
Language ar, bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, lt, lv, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk
PDF (18 MB)

Wilo-SiFire FIRST

Article Number 4243594
Edition 2020-12
Number of pages 84
Language en
PDF (12 MB)

Wilo-Atmos GIGA-NF

Article Number 4243597
Edition 2022-02
Number of pages 40
Language en
PDF (4 MB)

Wilo-Medana CV1-L

Article Number 4245263
Edition 03/2021
Number of pages 196
Language da, de, en, es, fi, fr, it, nl, no, pl, ru, sv, tr, uk
PDF (6 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (327 KB)
Product selection
Number of results: 200
System output without standby pump Q
29 … 323 m³/h
[200]
Product descriptionSystem output without standby pump QMaximum operating pressure PNGross weight, approx. mArticle number
SiFire-FIRST-65/250-226-31,5D
141 m³/h
16 bar
696 kg
4240847
SiFire-FIRST-65/250-226-31,5DJ
141 m³/h
12 bar
746 kg
4240900
SiFire-FIRST-65/250-248-37D
111 m³/h
16 bar
731 kg
4240848
SiFire-FIRST-65/250-248-37DJ
111 m³/h
12 bar
781 kg
4240901
SiFire-FIRST-65/250-248-37E
111 m³/h
16 bar
694 kg
4240742
SiFire-FIRST-65/250-248-37EJ
111 m³/h
12 bar
743 kg
4240795
SiFire-FIRST-65/250-258-45E
113 m³/h
16 bar
801 kg
4240743
SiFire-FIRST-65/250-258-45EJ
113 m³/h
12 bar
810 kg
4240796
SiFire-FIRST-65/250-258-47,7D
113 m³/h
16 bar
760 kg
4240849
SiFire-FIRST-65/250-258-47,7DJ
113 m³/h
12 bar
809 kg
4240902
SiFire-FIRST-65/250-264-47,7D
114 m³/h
16 bar
760 kg
4240850
SiFire-FIRST-65/250-264-47,7DJ
114 m³/h
12 bar
809 kg
4240903
SiFire-FIRST-65/250-264-55E
114 m³/h
16 bar
820 kg
4240744
SiFire-FIRST-65/250-264-55EJ
114 m³/h
12 bar
870 kg
4240797
SiFire-FIRST-80/200-185-22E
179 m³/h
16 bar
584 kg
4240745
SiFire-FIRST-80/200-185-22EJ
179 m³/h
12 bar
633 kg
4240798
SiFire-FIRST-80/200-185-26,5D
179 m³/h
16 bar
675 kg
4240851
SiFire-FIRST-80/200-185-26,5DJ
179 m³/h
12 bar
725 kg
4240904
SiFire-FIRST-80/200-195-26,5D
188 m³/h
16 bar
675 kg
4240852
SiFire-FIRST-80/200-195-26,5DJ
188 m³/h
12 bar
725 kg
4240905
SiFire-FIRST-80/200-195-30E
188 m³/h
16 bar
642 kg
4240746
SiFire-FIRST-80/200-195-30EJ
188 m³/h
12 bar
692 kg
4240799
SiFire-FIRST-80/200-201-30E
191 m³/h
16 bar
642 kg
4240747
SiFire-FIRST-80/200-201-30EJ
191 m³/h
12 bar
692 kg
4240800
SiFire-FIRST-80/200-201-31,5D
191 m³/h
16 bar
675 kg
4240853
SiFire-FIRST-80/200-201-31,5DJ
191 m³/h
12 bar
725 kg
4240906
SiFire-FIRST-80/200-210-37D
195 m³/h
16 bar
710 kg
4240854
SiFire-FIRST-80/200-210-37DJ
195 m³/h
12 bar
760 kg
4240907
SiFire-FIRST-80/200-210-37E
195 m³/h
16 bar
673 kg
4240748
SiFire-FIRST-80/200-210-37EJ
195 m³/h
12 bar
722 kg
4240801
SiFire-FIRST-80/200-224-45E
200 m³/h
16 bar
740 kg
4240749
SiFire-FIRST-80/200-224-45EJ
200 m³/h
12 bar
790 kg
4240802
SiFire-FIRST-80/200-224-47,7D
200 m³/h
16 bar
739 kg
4240855
SiFire-FIRST-80/200-224-47,7DJ
200 m³/h
12 bar
789 kg
4240908
SiFire-FIRST-80/200-228-47,7D
202 m³/h
16 bar
739 kg
4240856
SiFire-FIRST-80/200-228-47,7DJ
202 m³/h
12 bar
789 kg
4240909
SiFire-FIRST-80/200-228-55E
202 m³/h
16 bar
835 kg
4240750
SiFire-FIRST-80/200-228-55EJ
202 m³/h
12 bar
884 kg
4240803
SiFire-FIRST-80/250-235-55E
227 m³/h
16 bar
848 kg
4240751
SiFire-FIRST-80/250-235-55EJ
227 m³/h
12 bar
897 kg
4240804
SiFire-FIRST-80/250-235-66D
227 m³/h
16 bar
807 kg
4240857
SiFire-FIRST-80/250-235-66DJ
227 m³/h
12 bar
857 kg
4240910
SiFire-FIRST-100/200-212-45E
250 m³/h
16 bar
795 kg
4240753
SiFire-FIRST-100/200-212-45EJ
250 m³/h
12 bar
845 kg
4240806
SiFire-FIRST-100/200-212-47,7D
250 m³/h
16 bar
794 kg
4240859
SiFire-FIRST-100/200-212-47,7DJ
250 m³/h
12 bar
844 kg
4240912
SiFire-FIRST-100/200-222-55E
323 m³/h
16 bar
890 kg
4240754
SiFire-FIRST-100/200-222-55EJ
323 m³/h
12 bar
939 kg
4240807
SiFire-FIRST-100/200-222-66D
323 m³/h
16 bar
849 kg
4240860
SiFire-FIRST-100/200-222-66DJ
323 m³/h
12 bar
899 kg
4240913