Technical data
Hydraulic data
Maximum operating pressure PN 2 bar
Min. fluid temperature Tmin 3 °C
Max. fluid temperature Tmax 40 °C
Min. ambient temperature Tmin 3 °C
Max. ambient temperature Tmax 40 °C
Switching volume V 900 l
Macerator no
Motor data
Mains connection 3~400 V, 50 Hz
Rated current IN 9,5 A
Phase 3
Rated speed n 1450 1/min
Number of poles 4
Activation type Direct On Line (DOL)
Max. switching frequency t 15 1/h
Power consumption P1(Q=max.) of selected impeller * number of pumps P1 5500 W
Motor efficiency class IE0
For Wilo pumps FA 10.33-223E + FK 17.1-4/8K
Insulation class H
Protection class IP68
Materials
Pump housing Grey cast iron
Impeller Ductile cast iron
Shaft Stainless steel
Motor housing Grey cast iron
Installation dimensions
Operating mode (non-immersed) S1
Pipe connection on the discharge side DN 100
Pipe connection on the suction side DN 200

Wilo-EMUport CORE 60.2

Product data
Brand Wilo
Product description EMUport CORE 60.2-18/540
Article number 2554549
EAN number 4062679160962
Colour black/silver
Minimum order quantity 1
Date of sales availability 2021-11-01
Packaging
Packaging type Euro pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1900 mm
Length L 1830 mm
Height with packaging 2110 mm
Height H 1960 mm
Width with packaging 1900 mm
Width W 1760 mm
Gross weight, approx. m 652 kg
Net weight, approx. m 602 kg
Tender text

Fully submersible and automatically operated sewage lifting unit with solids separation system and two submersible sewage pumps in alternating operation without peak load

Fluid

For the collection and pumping of these fluids in commercial areas:

  • Sewage with faeces
  • Sewage without faeces

Sewage pumping according to 12050

The lifting unit follows DIN EN 12050-1.

Construction

All-in-one gastight and watertight collection tank:

  • Without constructive welded joints
  • With an inspection opening
  • Rounded edges and sloped floor with the deepest point directly below the pump, preventing deposits and the drying of solids at critical points

Two solids separation tanks:

  • Pre-filtering sewage upstream of the collection tank
  • Separately lockable

Sewage pump:

  • Mounted directly on the collection tank
  • Two high-performance submersible sewage pumps run in alternating operation as a redundant double-pump system

Operation of the two pumps at the same time is strictly forbidden.

Supply box/distributor:

  • For connection to the inlet pipe
  • With transparent cover

Manual flushing line for the collection tank

Scope of delivery

  • Solids separation system with two dry-installed submersible pumps
  • 2x shut-off valves for the solids separation tanks
  • 2x non-return valves at the discharge side
  • 2x shut-off valves at the discharge side
  • Consolidation of the discharge pipe
  • 1x level probe
  • 1x floor fixation as cross beam
  • 2.5 m ventilation hose
  • 1x maintenance kit with a blanking cover for the opening on the collection tank and a blanking cover for the discharge pipe
  • Installation and operating instructions
Operating data
For Wilo pumps FA 10.33-223E + FK 17.1-4/8K
Approved field of application
Fluid temperature T 3 °C
Max. fluid temperature, for short periods up to 3 min. T 40 °C
Ambient temperature T 3 °C
Maximum operating pressure PN 2 bar
Max. permissible pressure in the pressure pipe P 6 bar
Product data
Gross volume of the tank V 1200 l
Switching volume V 900 l
Operating mode (non-immersed) S1
Height H 1960 mm
Length L 1830 mm
Width W 1760 mm
Diagonal dimension Diagonal axis 2000 mm
Motor data
Mains connection 3~400 V, 50 Hz
Voltage tolerance ±10 %
Rated power P2 4 kW
Rated speed n 1450 1/min
Rated current IN 9,5 A
Insulation class H
Protection class motor IP68
Activation type Direct On Line (DOL)
Max. switching frequency t 15 1/h
Motor protection Bimetall
Cable
Connection cable length L 20 m
Cable type H07RN-F
Cable cross-section 7G1,5 mm²
Mains plug no
Type of connection cable Non-detachable
Materials
Tank PE
Pump housing Grey cast iron
Impeller Ductile cast iron
Shaft Stainless steel
Gasket material FKM
Motor housing Grey cast iron
Installation dimensions
Pipe connection on the suction side DN 200
Pipe connection on the discharge side DN 100
Connection venting Ø 75
Ordering information
Brand Wilo
Product description EMUport CORE 60.2-18/540
Net weight, approx. m 602 kg
Article number 2554549
Documents

Installation and operating instructions

Wilo-EMUport CORE

Article Number 6092612
Edition 2025-04
Number of pages 44
Language en
PDF (8 MB)

Wilo-Control SC-L...-FTS

Article Number 2545546
Edition 08-2016
Number of pages 112
Language de, en, es, fr, hu
PDF (13 MB)

Operating instructions (digital)

Wilo-EMUport CORE

Article Number 6092612
Edition 2025-04
Language bg, cs, de, el, en, et, fr, hu, ko, lt, lv, pl, ro, tr
HTML (211 MB)

Certification booklet

Wilo-EMUport Core 20.2 / 45.2 / 50.2 / 60.2

Article Number 2546469
Edition 2021-07
Number of pages 40
Language ar, az, ba, bg, cs, da, de, el, en, es, et, fi, fr, ga, hr, hu, it, ko, lt, lv, mk, nl, no, pl, pt, ro, ru, sk, sl, sq, sr, sv, tr, uk, zh
PDF (3 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (287 KB)
BIM/CAD
Accessory

Level control with level sensor (4)

Stationary dry well installation (22)

Adapter (6)

Fittings (2)

Installation/setup (8)

Pipes/pipe joints (7)

Pump control (3)

Pump control/accessories (1)

Alarm signal (5)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Maintenance
Maintenance COMFORT EMUport Core
    

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance PREMIUM EMUport Core
    

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Includes wearing parts

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Commissioning
Commissioning EMUport Core
    

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

More suitable services

Extended Warranty
Extended Warranty EMUport Core
    

In combination of a new pump or system Wilo offers an extended warranty of up to five years in combination with commissioning and maintenance by the Wilo Service.

Extended warranty includes:

  • Full protection and predictable cost security
  • Regular maintenance work by the Wilo Service
Supervision
Supervision EMUport Core
    

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation EMUport Core
    

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
System Optimisation
System Optimisation EMUport Core
    

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions EMUport Core
    

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair EMUport Core
    

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report