ElectronicControl | Wilo
Your advantages
ElectronicControl

Your advantages

  • Easy adjustment and operation
  • Large display with simplified menu and navigation in addition to LED status indicator
  • Meets the EMC standards for domestic use (EN 61000-6-2 and EN 61000-6-3)
  • Comfort functions: PID (APP function), frost protection automatic system AIS, automatic restart after error ART
  • Float switch can be connected optionally
Series description

Construction

Water-cooled frequency converter with built-in pressure and flow monitor

Application

For controlling pumps in the fields:

  • Water supply
  • Rainwater utilisation
  • Irrigation and spraying

Equipment/function

  • With 1.4 m connection cable and plug pre-cabled
  • Pre-cabled motor cable with cable end sleeves
  • Built-in EMC filter
  • with built-in pressure and flow monitors
  • Restoration of the selected settings after interruption of the power supply

Scope of delivery

1 control device Electronic Control incl.:

  • Pre-cabling with 1.4 m connection cable and plug
  • Pre-cabled motor cable with cable end sleeves
  • Installation and operating instructions

Type key

Example;

ElectronicControl MT6

ElectronicControl

Control device with frequency converter

M

Power supply of the electronic control 1~230 V

T

Power supply of the motor T = 3~230 V, M = 1~230 V

6

Max. current consumption in A

Technical data

  • Max. operating pressure: 15 bar
  • Setting range: 0.5 to 12 bar
  • Max. volume flow: 15 m3/h
  • Max. fluid temperature: 40 °C
  • Min. fluid temperature: 0 °C
  • Max. ambient temperature: 50 °C
  • Input voltage: 1~230 V, 50/60 Hz
  • Excess current protection: +20 % of the maximum current consumption over a period of 10 s
  • Protection class: IP55

Materials

  • Safety disk AISI 304 L
  • Pressure sensor: Al2O3
  • Cooling module: CuZn33
  • Housing, safety disk and cover: Polyamide: 6 - 50% glass fibres
  • Flow monitor: Acetal resin Hostaform C2521 14
  • Seals: Natural rubber
  • Cap for minimum flow rate: Noryl GFN2V

Description/construction

  • Complete and automatic protection against:
    • Excess current
    • Dry run
    • Undervoltage and overvoltage
    • Excess temperature
    • Short-circuit
  • History log: operating hours, number of starts, number of connection to the power supply, type and number of alarm signals since commissioning the device

Series

ElectronicControl
Downloads

Certificate REACH (Documents)

REACH regulation

Edition 2020-08
Page format 209.9 x 296.7 mm
Number of pages 4
PDF (1 MB)