Your advantages
Wilo-Stratos MAXO–Z (North America)

Your advantages

  • Intuitive operation by means of application-guided settings with the Setting assistant plus the combination of a new display and operating button using Green Button Technology.
  • Highest standard of drinking water hygiene and energy efficiency with the new, innovative, intelligent T-const. control function.
  • Optimum hygiene promotion through thermal disinfection detection.
  • Latest communication interfaces (e.g. Bluetooth) for connection to mobile devices and direct pump networking for multiple pump control via Wilo Net.
Series description
Wilo-Stratos MAXO-Z

Design

Smart glandless circulator with oval flange and round flange connection and EC motor with integrated electronic power adjustment

Application

Domestic hot water circulation systems of all kinds, hot-water heating systems of all kinds, air-conditioning, closed cooling circuits, industrial circulation systems

Max. Flow: 240 GPM

Max. Head: 40 feet

Equipment/function

Field of application

The pump facilitates an operation with highest system efficiency via precise setting of the control mode for the system-specific application (e.g. radiator, underfloor heating, ceiling cooling).

Heating

  • Radiator
  • Underfloor heating
  • Ceiling heating
  • Fan heater
  • Hydraulic shunt
  • Heat exchanger

Cooling

  • Ceiling cooling
  • Underfloor cooling
  • Air-conditioning devices
  • Hydraulic shunt
  • Heat exchanger

Heating and cooling combined

  • Automatic switchover

The following control modes are available depending on the selected application:

Control modes

  • Constant speed (control mode)
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • Dynamic Adapt plus for continuous (dynamic) adjustment of the delivery rate to the current requirement
  • T-const. for constant temperature regulation
  • ΔT for differential temperature control
  • Constant Q for constant volume flow control
  • Multi-Flow Adaptation: Total volume flow determination through the feeder pump for the needs-based supply of secondary pumps in the heating circuit distributors
  • User-defined PID controller

Optional functions

  • Q-limitmax. for limiting the maximum volume flow
  • Q-limitmin. for limiting the minimum volume flow
  • No-Flow Stop (zero-flow-deactivation)
  • Automatic setback operation
  • Index circuit evaluator (Δp-c control with external actual value sensor)
  • Thermal disinfection detection
  • Variable pitch of Δp-v pump curve

Manual settings

  • Selection of the field of application using the Setup Guide
  • Setting the related operating parameters
  • Nominal duty point: direct input of calculated duty point at Δp-v
  • Status display
  • Setting and resetting the energy meters (heating and cooling)
  • Pump venting function
  • Key lock for disabling the settings
  • Function for resetting the factory settings or the saved restoration points (parameter sets)
  • Parameterising the analogue inputs
  • Parameterising the binary inputs
  • Parameterising the relay outputs

Automatic functions

  • Power adjustment according to requirements for energy-efficient operation depending on the operating mode
  • Setback operation
  • Deactivation at zero flow (No-Flow Stop)
  • Soft start
  • Automatic troubleshooting routines (e.g. deblocking function)
  • Switchover heating/cooling mode
  • Full motor protection with integrated trip electronics

External control inputs and their functions

2 x analogue inputs:

  • Signal types: 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, PT1000
  • Applications: Remote adjustment of the setpoints in every control mode (except Multi-Flow Adaptation), sensor inputs for temperature, differential pressure or free sensor in user-defined PID-operating mode

2 x digital inputs:

  • For potential-free control outputs or switch
  • Parametrizable functions:
    • Ext. Off
    • Ext. Min
    • Ext. Max
    • MANUAL (BMS-OFF)
    • Key lock
    • Switchover between heating/cooling mode

Wilo Net for dual pump management of 2 single pumps, communication of several pumps with each other and pump-remote adjustment via gateway

Signal and display functions

  • Display status operation display:
    • Setpoint
    • Actual delivery head
    • Actual volume flow
    • Power consumption
    • Electric consumption
    • Temperatures
  • Status display LED: Faultless operation (green LED), pump communication (blue LED)
  • Display status of display fault (display red):
    • Error codes and error description in full text
    • Remedial measures
  • Display status of display warning (display yellow):
    • Warning codes and description of the warning in full text
    • Remedial measures
  • Display status process indicator display (display blue):
    • Pump venting
    • Update procedure
  • Display BMS communication (display blue):
    • Summary of the active BMS parameters (baud rate, address,...)
  • Collective fault signal SSM (potential-free changeover contact)
  • Collective run signal SBM (potential-free normally open contact)

Data exchange

  • Bluetooth interface for wireless data exchange and remote operation of the pump using a smartphone or tablet.
  • Serial digital interface Modbus RTU for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module Modbus RTU).
  • Serial digital interface BACnet MS/TP for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module BACnet MS/TP).

Equipment

  • Various integrated communication interfaces and optionally usable CIF module plug-in position
  • 5 cable inlets for connecting the communication interfaces
  • Bluetooth interface
  • High resolution graphic display with green button and 2 additional buttons
  • User-friendly terminal room
  • Integrated temperature sensor in the pump housing
  • Quick electrical connection with optimized Wilo-Connector including a ½ NPT connection adapter for the power supply

Typekey

Example:

Stratos MAXO-D 3x3-40

Stratos MAXO

Pump designation

Single Pump

-D

Double Pump

-Z

Single pump for drinking water circulation system

3

Flange Connection in inches

Continuously variable setpoint height 3 – 40 ft

3-40

Minimum delivery head 3.3 ft

Maximum delivery head 39.4 ft

Technical data

  • Permissible temperature range
    • Drinking water up to 3.57 mmol/l: 32 °F (0 °C) to 176 °F (+80 °C)
    • Heating water: 14 °F (-10 °C) to 230 °F (+110 °C)
  • Mains connection:
    • 1~115 V, 50/60 Hz (depending on type),
    • 1~230 V-240 V, 50/60 Hz
  • Enclosure: Type 2
  • Flange connection: 1.25, 2 and 3 inch
  • Max. operating pressure: 145 psi
  • Insulation class: F
  • Emitted interference in acc. with: EN 61800-3:2004+A1:2012 / residential environment (C1)
  • Interference resistance in acc. with: EN 61800-3:2004+A1:2012 / industrial environment (C2)

Materials

  • Pump housing made of stainless steel
  • Thermal insulation: polypropylene
  • Impeller: Plastic
  • Shaft: Stainless steel
  • Bearing: carbon

Construction

  • Smart glandless circulator with EC motor and integrated electronic power adjustment
  • Green Button Technology and graphic display
  • Motor protection with trip electronics
  • Plug connection for functional extension with optional CIF module for building automation (BA)
  • Impeller with three-dimensionally curved blades and plastic sealing tube made of carbon fibre composite material

Scope of delivery

  • Pump
  • Optimized Wilo-Connector with ½ NPT connection adapter
  • 5x threaded cable gland M16 x 1.5
  • Gaskets for 1.25 and 2 inch flange connection
  • Installation and operating instructions

Options

NO VALUE

Accessories

  • PT 1000 (B) pipe contact sensor (for domestic hot water)
  • PT 1000 (AA) sensor for installation in immersion well
  • Differential pressure sensor
  • Wilo CIF modules: Modbus RTU, BACnet MS/TP
Documents

Installation and operating instructions

Wilo-Stratos MAXO/-D/-Z

Article Number 2226402
Edition 2023-10
Number of pages 324
PDF (6 MB)

Certification booklet

Stratos MAXO, Stratos MAXO-D, Stratos MAXO-Z, Stratos , Stratos-D, Stratos-Z, Stratos-ZD, Yonos MAXO,Yonos MAXO-D, Yonos MAXO-Z, Yonos ECO BMS, Yonos PARA HF, Stratos PARA, Stratos PARA-Z, TOP-Z, TOP-S Transportsysteme

Article Number 2209011
Edition 2022-11
Number of pages 72
PDF (28 MB)

Release notes Software

Release notes Stratos MAXO

Article Number 2212705
Edition 2021-04
Number of pages 60
PDF (4 MB)
Product selection