Hae
Ottaa yhteyttä
Sähköposti
Tuoteluettelon laatiminen
Suosikkini
Tuotevertailu
Wilo-Fire SPK OPTI | Wilo
Your advantages
Wilo-Fire SPK OPTI

Your advantages

  • Two possible models depending on installation conditions
  • Compact system on a single baseplate for easy transport and installation
  • Robust vertical multistage pump with stainless steel impellers
  • Very high control quality and very simple operation due to the firefighting dedicated controller
  • Safety valve on pump discharge to protect the pump in case of low flow condition
  • Pressure-loss optimised hydraulics of entire system
Series description

Design

Pressure-boosting systems for firefighting in accordance with EN 16925.

Composed of 2 electrical multistage vertical pumps: one main pump and one jockey pump.

Application

Fully automatic water supply for fire-extinguishing systems with sprinklers in residential building types 2 and 3 of EN16925 standard such as apartment buildings, care homes, student accommodation, small hotels.

Equipment/function

    • 1 vertical multistage pump of series Helix VF 10,16,22,36 with IE3 equivalent standard motor.
    • Jockey pump from Medana CV1-L series with pressure switch and vertical pressure vessel 20L, PN16.
    • Flow regulation valve on the jockey pump discharge to set the flow
    • All-in-one controller integrated with alarm control panel fixed on robust supports, for all the system.
    • Electro-galvanised steel base frame.
    • Pipework made of steel and epoxy painted or stainless steel. Screwed manifold with flanged adaptor.
    • Shut-off butterfly valve with security lock on discharge side of each pump.
    • Non-return valve, on discharge side of each pump.
    • One flow switch on the discharge manifold for alarm triggering.
    • One circuit with double pressure switch, manometer, non-return valve, valve, for main pump for automatic start.
    • Concentric cone on discharge side on main pump, for speed limitation according to parameters requested in EN16925 standard.
    • Pressure gauge on discharge side.
    • Accessories on request:
    • Flow meter
    • Kit eccentric cone on suction side complete of butterfly valve with hand lever or handwheel.
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Antivibration sleeve for manifold
    • Remote alarm switchgear

Typekey

NO VALUE

Technical data

  • Power supply 3x400 V +/- 10%, 50 Hz (3x230 V +/- 10%, 50 Hz for jockey pump)
  • Fluid temperature max. +40 °C
  • Ambient temperature max. 4 to +40 °C
  • Maximum operating pressure 16 bar
  • Volume flow from 8 to 45 m³/h
  • Maximum delivery head 110 m
  • Pump impellers material: stainless steel 1.4307 (AISI 304L)
  • IE3 standard motors
  • Maximum power 15 kW
  • Rated speed 2900 rpm
  • IP rating IP55
  • Epoxy painted pipes and hydraulic connections
  • IP rating for switchgear: IP54

Materials

For vertical multistage pump

  • Impellers made of AISI304/1.4301 stainless steel
  • Pump housing made of AISI304/1.4301 stainless steel
  • Shaft made of AISI431/1.4057 stainless steel
  • O-ring-seals made of EPDM

For jockey pump

  • Impellers made of AISI304/1.4301 stainless steel
  • Pump housing made of AISI304/1.4301 stainless steel
  • Shaft made of AISI304/1.4301 stainless steel
  • O-ring-seals made of EPDM

Construction

  • Base frame: Made of electro-galvanised steel profiles, provided with brackets for control boxes. Anti-vibration supports in contact with the ground.
  • Pipework: Complete pipework screwed with flanged adaptors made of stainless steel/epoxy painted steel, suitable for connection of all commonly used piping materials; the pipework is sized corresponding to the overall hydraulic performance of the pressure-boosting system.
  • Pumps: 1 vertical multistage pump.
  • Fittings: For main pump, each pump is fitted on discharge side with a butterfly valve and non-return valve-, both with epoxy painted and adapted for screwed connection.
  • Sensors and display: 2 pressure switch 2/16 bar per pump located on the discharge side for activating the pump start through the switch cabinet controller. Discharge side pressure gauge (ø 63 mm) located close to the pressure switches.
  • Control device/controller: The system is standard equipped with one switch cabinet with integrated alarm control panel for electric and jockey pump control.

Scope of delivery

  • Factory-mounted, connection-ready pressure-boosting system checked for functionality and impermeability
  • Packaging
  • Installation and operating instructions
  • Necessary accessories following request
Documents

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (271 KB)

CE

CE 2215816-02

Number of pages 6
Language language neutral
PDF (216 KB)
Product selection
Product description Maximum operating pressure PNGross weight, approx. mArticle number
Fire SPK OPTI VF1003
16 bar
176 kg
4239957
Fire SPK OPTI VF1003 WSM
16 bar
161 kg
4239976
Fire SPK OPTI VF1004
16 bar
182 kg
4239958
Fire SPK OPTI VF1004 WSM
16 bar
167 kg
4239977
Fire SPK OPTI VF1006
16 bar
191 kg
4239959
Fire SPK OPTI VF1006 WSM
16 bar
176 kg
4239978
Fire SPK OPTI VF1008
16 bar
199 kg
4239960
Fire SPK OPTI VF1008 WSM
16 bar
184 kg
4239979
Fire SPK OPTI VF1011
16 bar
206 kg
4239961
Fire SPK OPTI VF1011 WSM
16 bar
191 kg
4239980
Fire SPK OPTI VF1602
16 bar
202 kg
4239962
Fire SPK OPTI VF1602 WSM
16 bar
187 kg
4239981
Fire SPK OPTI VF1603
16 bar
202 kg
4239963
Fire SPK OPTI VF1603 WSM
16 bar
187 kg
4239982
Fire SPK OPTI VF1604
16 bar
201 kg
4239964
Fire SPK OPTI VF1604 WSM
16 bar
186 kg
4239983
Fire SPK OPTI VF1606
16 bar
204 kg
4239965
Fire SPK OPTI VF1606 WSM
16 bar
189 kg
4239984
Fire SPK OPTI VF1608
16 bar
238 kg
4239966
Fire SPK OPTI VF1608 WSM
16 bar
223 kg
4239985
Fire SPK OPTI VF2202
16 bar
229 kg
4239967
Fire SPK OPTI VF2202 WSM
16 bar
207 kg
4239986
Fire SPK OPTI VF2203
16 bar
231 kg
4239968
Fire SPK OPTI VF2203 WSM
16 bar
209 kg
4239987
Fire SPK OPTI VF2204
16 bar
241 kg
4239969
Fire SPK OPTI VF2204 WSM
16 bar
219 kg
4239988
Fire SPK OPTI VF2206
16 bar
279 kg
4239970
Fire SPK OPTI VF2206 WSM
16 bar
257 kg
4239989
Fire SPK OPTI VF2207
16 bar
295 kg
4239971
Fire SPK OPTI VF2207 WSM
16 bar
273 kg
4239990
Fire SPK OPTI VF3602
16 bar
295 kg
4239973
Fire SPK OPTI VF3602 WSM
16 bar
270 kg
4239992
Fire SPK OPTI VF3602/2
16 bar
287 kg
4239972
Fire SPK OPTI VF3602/2 WSM
16 bar
252 kg
4239991
Fire SPK OPTI VF3603/1
16 bar
311 kg
4239974
Fire SPK OPTI VF3603/1 WSM
16 bar
286 kg
4239993
Fire SPK OPTI VF3604
16 bar
341 kg
4239975
Fire SPK OPTI VF3604 WSM
16 bar
316 kg
4239994