P235
Technical data | |
---|---|
Mains connection | 1~230 V, 50 Hz |
Rated power P2 | 370 W |
Control | Without frequency converter |
Activation type | Direct On Line (DOL) |
Electromagnetic compatibility | EN 61000 |
Connection standard | EN 1254 |
Installation | Floor installation |
Operating Data | |
---|---|
Max. inlet pressure | 8 bar |
Dimensions | |
---|---|
Dimensions H1 | 775.0 mm |
Dimensions H2 | 730.0 mm |
Dimensions H3 | 225.0 mm |
Dimensions H4 | 545.0 mm |
Dimensions H5 | 590.0 mm |
Dimensions L | 455.0 mm |
Pressurisation Unit Wiring Diagram
Product data | |
---|---|
Brand | Wilo |
Product description | P235 |
Article number | 2819495 |
EAN number | 5013608000612 |
Colour | Green/silver/grey |
Minimum order quantity | 1 |
Date of sales availability | 2012-06-01 |
Packaging | |
---|---|
Packaging type | Euro pallet |
Packaging property | Transport packaging |
Pieces per pallet | 4 |
Number per layer | 4 |
Dimension, weight | |
---|---|
Length with packaging | 1000 mm |
Length L | 455 mm |
Height with packaging | 925 mm |
Height H | 775 mm |
Width with packaging | 800 mm |
Width W | 350 mm |
Gross weight, approx. m | 48 kg |
Net weight, approx. m | 33 kg |
The Wilo Comfort twin pump pressurisation units (duty / standby) are designed for use on heating or chilled water systems up to and including 3.5, 6.0 and 8.0 bar cold fill pressures.
The unit is fitted with an 18 litre polypropylene break tank c/w type AB air gap to BS13077:2008 and water regulations 1999, Wras approved equilibrium ball float valve to BS1212 and a low water float switch and strainers for pump protection.
Each pump is fitted with a non return valve and quick release couplings for ease of maintenance. The pressure transducer monitors the system pressure and feeds a 0-10v signal to the comfort controller.
Comfort Controller is complete with the following features:
- User friendly interface that has a 2 line LCD backlight display
- Healthy / fail LED
- Password protection
- System Fill for initial fill of system
- Pump check routine, that runs both pumps for 2 seconds if inactive for 7-90 days
- Pump trip and fail alarms
- System leak alarm
- Excessive starts alarm
- Alarm log
- Hours Run
- Automatic duty rotation
- Connectivity: BACnet = RS485 interface, BACnet MS/TP protocol
2 wire BACnet
Volt Free Contacts are supplied with terminals for common, normally open and normally closed.
(5A, 230V)
Pump no.1 trip, Pump no. 1 run, Pump no.2 trip, Pump no. 2 run, High Pressure, Low Pressure, Excess starts, Low water and Boiler Interlock (NC only)
(10A, 230V)
To be selected from Power fail, Common alarm, Common pressure alarm
Standards Applied:
Low Voltage and Machinery Directive 2006/42/EC, EMC Directive EMC 2004/108/EC, BSEN809, BS7074-1 to 3, BS13077:2008 and water regulations 1999.
Technical data | |
---|---|
Mains connection | 1~230 V, 50 Hz |
Control | Without frequency converter |
Operating Data | |
---|---|
Max. inlet pressure | 8 bar |
Ordering information | |
---|---|
Width W | 350 mm |