Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-SiFire FIRST | Wilo

Wilo-SiFire FIRST

A modular design for a wide field of applications.

Your advantages
Wilo-SiFire FIRST D

A modular design for a wide field of applications.

The Wilo-SiFire FIRST is a flexible modular norm pump system in accordance with EN 12845. It could be equipped with electric or diesel motor and jockey pump for a wide field of applications. The compact system is fixed on an universal baseplate which makes the transport, installation and maintenance very easy. The robust design enables a long lifetime.


Your advantages

  • Modular standard pump system with electric or diesel motor for a wide field of applications and high flexibility in designing
  • Long service life thanks to robust design
  • Easy transport, installation and maintenance thanks to an universal baseplate
  • Intuitive handling on specific firefighting switchgear
  • Equipment and pipes calibrated in accordance with EN 12845 standard
  • Quick installation thanks to preinstalled hydraulic and electric components on the discharge side
Series description
Wilo-SiFire FIRST

Design

Pressure-boosting systems for firefighting in accordance with EN 12845.

Depending on the model, composed of 1 horizontal base plate pump – EN 733 – with spacer coupling or cardanic joint, electrical or diesel motor and electrical multistage vertical jockey pump.

Application

Fully automatic water supply for fire-fighting systems with sprinklers in residential, commercial and public buildings, hotels, hospitals, department stores, and for office or industrial buildings.

Equipment/function

  • 1 horizontal base plate pump per system from 32-200 to 100-200 series, with IE3 equivalent standard motor or diesel engine.
  • Diaphragm, to avoid over heating at zero flow, directly installed on the main pump housing.
  • Jockey pump from Medana CV1-L series
  • One controller fixed on robust supports. Model E for electric motor and D for diesel engine, both equipped with a firefighing dedicated controller, plus additional control J for jockey pump, if present.
  • Electro galvanised steel base frame.
  • Pipe work made of steel and epoxy painted. Manifold with flanges.
  • Shut-off butterfly valve with security lock on discharge side of each pump.
  • Non-return valve, on discharge side of each pump.
  • One circuit with double pressure switch, manometer, non return valve, valve, for main pump for automatic start.
  • Concentric cone on discharge side on main pump, for speed limitation according to prameters requested in EN 12845 standard.
  • Connection DN 2" for the priming tank per pump.
  • Pressure gauge on discharge side.
  • Only for diesel engine model:
    • 2 batteries on the base plate and battery chargers in the control box.
    • Separated fuel tank with level sensor and adequate volume to allow 6 hours operating autonomy.
  • Accessories on request:
    • Horizontal priming tank 500 L, with floating valve and pressure switch for low level alarm.
    • Flow meter
    • Kit eccentric cone on suction side complete of butterfly valve with hand lever or hand wheel.
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Antivibration sleeve for manifold
    • Remote panel to transfer alarms level A+B
    • Densimeter for battery
    • Spare part kit for diesel engine
    • Silencer (30 dBA) for diesel engine
    • Hydraulic heat exchanger for diesel engine

Typekey

Example:

Wilo-SiFire FIRST 40/200-180-7.5 EJ

SiFire

Compact pressure-boosting system for firefighting applications in accordance with the EN 12845 standard

FIRST

Optimised functionalities

40/200

Type of main pump

180

DN nominal impeller diameter of the main pump

7.5

Power of the electric motor [kW] *

EJ

Configuration

E

1 electric pump

D

1 diesel pump

J

1 jockey pump

* = minimum motor power, do not fall below

Technical data

Allowed fluid:

  • Non-aggressive clean water, free of abrasive or long fiber substances

Application field:

  • Power supply 3~400 V, 50 Hz (1~230 V, 50 Hz for Jockey pump and Diesel pump control panel)
  • Fluid temperature max. +25 °C
  • Ambiant temperature min/max. +4 to +40 °C (+10 to +40 °C if diesel pump is installed)
  • Maximum operating pressure 16 bar (12 bar with Jockey pump)
  • Maximum inlet pressure 6 bar
  • Flow from 10 to 320 m³/h
  • Maximum head 95 m

Pump impellers:

  • Bronze for main horizontal base plate pump
  • Stainless steel for vertical multistage jockey pump

Electrical Motor:

  • IE3 standard motors
  • Maximum power 55 kW
  • Nominal speed 2900 rpm
  • Protection class IP55

Diesel engine:

  • Direct injection or supercharged diesel motor with air or water cooling.
  • Maximum power 66 kW
  • Forced lubrification with gear pump and oil filter
  • Cooling depending on the power: Up to 17,7 kW with air flow, direct or with water in closed circuit with radiator. From 26,5 kW with heat exchanger water/water.

Other:

  • Epoxy painted pipes and hydraulic connections
  • Discharge nominal connection diameters DN 50 until DN 150 - EN 1092, PN 16
  • Suction nominal connection diameters DN 50 until DN 125 - EN 1092, PN 16
  • Protection class for Control box: IP54

Materials

For horizontal base plate pump

  • Impellers made of Bronze CuSn10 or CuAl10Fe5Ni5
  • Wear rings made of AISI316L/1.4409 stainless steel
  • Pump housing made of cast iron EN-GJL-250
  • Shaft made of AISI420/1.4021 stainless steel

For Jockey pump

  • Impellers made of AISI304/1.4301 stainless steel
  • Pump housing made of AISI304/1.4301 stainless steel
  • Shaft made of AISI304/1.4301 stainless steel
  • O-ring-seals made of EPDM

Construction

  • Base frame: Made of electro galvanised steel profiles, provided with brakets for control boxes. On the bottom part, special rectangular holes for forklift and integrated hooks for lifting straps.
  • Pipe work: Complete pipe work with flanges made of epoxy painted steel, suitable for connection of all commonly used piping materials; the pipe work is sized corresponding to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 horizontal base plate pump – EN 733 – with spacer coupling, electrical or diesel motor. Back pull out model for easy access to pump internal components without moving motor or pipes.
  • Fittings: For main pump, each pump is fitted on discharge side with a butterfly valve and non return valve, both with epoxy painted and adapted for flanged connection.
  • Tank: Separated fuel tank made of epoxy painted steel with leackage bacin.
  • Sensors and display: 2 Pressure switch 2/16 bar per pump located on the discharge side for activating the pump start through the control box controller. Discharge-side pressure gauge (ø 63 mm) located close to the pressure switches.
  • Control device/controller: The system is standard-equipped with control box for electric or diesel motor and a jockey pump controller, if present.

Scope of delivery

  • Factory-mounted, ready-for-installation pressure-boosting system, which has been checked for functionality and impermeability
  • Installation and operating instructions
  • Required accessories on request
Documents

Installation and operating instructions

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Number of pages 451
Language ar, bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, lt, lv, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk
PDF (18 MB)

Wilo-SiFire FIRST

Article Number 4243594
Edition 2020-12
Number of pages 84
Language en
PDF (12 MB)

Wilo-Atmos GIGA-NF

Article Number 4243597
Edition 2022-02
Number of pages 40
Language en
PDF (4 MB)

Wilo-Medana CV1-L

Article Number 4245263
Edition 03/2021
Number of pages 196
Language da, de, en, es, fi, fr, it, nl, no, pl, ru, sv, tr, uk
PDF (6 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (327 KB)
Product selection
Number of results: 200
System output without standby pump Q
29 … 323 m³/h
[200]
Product descriptionSystem output without standby pump QMaximum operating pressure PNGross weight, approx. mArticle number
SiFire-FIRST-40/200-212-15E
66 m³/h
16 bar
440 kg
4240715
SiFire-FIRST-40/200-212-15EJ
66 m³/h
12 bar
489 kg
4240768
SiFire-FIRST-40/250-218-15E
55 m³/h
16 bar
452 kg
4240716
SiFire-FIRST-40/250-218-15EJ
55 m³/h
12 bar
515 kg
4240769
SiFire-FIRST-40/250-218-17,7D
55 m³/h
16 bar
501 kg
4240822
SiFire-FIRST-40/250-218-17,7DJ
55 m³/h
12 bar
550 kg
4240875
SiFire-FIRST-40/250-226-17,7D
59 m³/h
16 bar
501 kg
4240823
SiFire-FIRST-40/250-226-17,7DJ
59 m³/h
12 bar
550 kg
4240876
SiFire-FIRST-40/250-226-18,5E
59 m³/h
16 bar
465 kg
4240717
SiFire-FIRST-40/250-226-18,5EJ
59 m³/h
12 bar
620 kg
4240770
SiFire-FIRST-40/250-244-22E
61 m³/h
16 bar
571 kg
4240718
SiFire-FIRST-40/250-244-22EJ
61 m³/h
12 bar
620 kg
4240771
SiFire-FIRST-40/250-244-26,5D
61 m³/h
16 bar
662 kg
4240824
SiFire-FIRST-40/250-244-26,5DJ
61 m³/h
12 bar
712 kg
4240877
SiFire-FIRST-40/250-250-26,5D
61 m³/h
16 bar
662 kg
4240825
SiFire-FIRST-40/250-250-26,5DJ
61 m³/h
12 bar
712 kg
4240878
SiFire-FIRST-40/250-250-30E
61 m³/h
16 bar
629 kg
4240719
SiFire-FIRST-40/250-250-30EJ
61 m³/h
12 bar
678 kg
4240772
SiFire-FIRST-50/160-147-5,5E
81 m³/h
16 bar
328 kg
4240720
SiFire-FIRST-50/160-147-5,5EJ
81 m³/h
12 bar
391 kg
4240773
SiFire-FIRST-50/160-147-6,8D
81 m³/h
16 bar
415 kg
4240826
SiFire-FIRST-50/160-147-6,8DJ
81 m³/h
12 bar
468 kg
4240879
SiFire-FIRST-50/160-155-6,8D
81 m³/h
16 bar
415 kg
4240827
SiFire-FIRST-50/160-155-6,8DJ
81 m³/h
12 bar
468 kg
4240880
SiFire-FIRST-50/160-155-7,5E
81 m³/h
16 bar
345 kg
4240721
SiFire-FIRST-50/160-155-7,5EJ
81 m³/h
12 bar
394 kg
4240774
SiFire-FIRST-50/160-173-11E
78 m³/h
16 bar
431 kg
4240722
SiFire-FIRST-50/160-173-11EJ
78 m³/h
12 bar
480 kg
4240775
SiFire-FIRST-50/160-173-12,9D
78 m³/h
16 bar
451 kg
4240828
SiFire-FIRST-50/160-173-12,9DJ
78 m³/h
12 bar
501 kg
4240881
SiFire-FIRST-50/160-178-12,9D
81 m³/h
16 bar
451 kg
4240829
SiFire-FIRST-50/160-178-12,9DJ
81 m³/h
12 bar
501 kg
4240882
SiFire-FIRST-50/160-178-15E
81 m³/h
16 bar
443 kg
4240723
SiFire-FIRST-50/160-178-15EJ
81 m³/h
12 bar
493 kg
4240776
SiFire-FIRST-50/200-182-10,5D
86 m³/h
16 bar
430 kg
4240830
SiFire-FIRST-50/200-182-10,5DJ
86 m³/h
12 bar
480 kg
4240883
SiFire-FIRST-50/200-182-11E
86 m³/h
16 bar
434 kg
4240724
SiFire-FIRST-50/200-182-11EJ
86 m³/h
12 bar
484 kg
4240777
SiFire-FIRST-50/200-192-12,9D
88 m³/h
16 bar
455 kg
4240831
SiFire-FIRST-50/200-192-12,9DJ
88 m³/h
12 bar
504 kg
4240884
SiFire-FIRST-50/200-192-15E
88 m³/h
16 bar
446 kg
4240725
SiFire-FIRST-50/200-192-15EJ
88 m³/h
12 bar
496 kg
4240778
SiFire-FIRST-50/200-202-15E
83 m³/h
16 bar
446 kg
4240726
SiFire-FIRST-50/200-202-15EJ
83 m³/h
12 bar
496 kg
4240779
SiFire-FIRST-50/200-202-17,7D
83 m³/h
16 bar
495 kg
4240832
SiFire-FIRST-50/200-202-17,7DJ
83 m³/h
12 bar
545 kg
4240885
SiFire-FIRST-50/200-210-17,7D
84 m³/h
16 bar
495 kg
4240833
SiFire-FIRST-50/200-210-17,7DJ
84 m³/h
12 bar
545 kg
4240886
SiFire-FIRST-50/200-210-18,5E
84 m³/h
16 bar
460 kg
4240727
SiFire-FIRST-50/200-210-18,5EJ
84 m³/h
12 bar
509 kg
4240780