Product design type | Glandless standard pump | Glandless standard high-efficiency pump | Glandless premium high-efficiency pump | Glandless premium smart-pump | Existing pump |
| | | | | |
| | | | | |
| | | | | |
Description | |
Product description | Star-Z 25/6-3 | Yonos PICO-Z 25/0,5-6 180 | Stratos PICO-Z 25/0,5-6 | Stratos MAXO-Z 30/0,5-8 PN 10 | NRW 35 PN16 |
Article number | 4047573 | 4255418 | 4255434 | 2164670 | - |
Series | Wilo-Star-Z | Wilo-Yonos PICO-Z | Wilo-Stratos PICO-Z | Wilo-Stratos MAXO-Z | - |
Mains connection | 1~230 V ±10%, 50 Hz | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | - |
Port-to-port length | 180 mm | 180 mm | 180 mm | 180 mm | 210 mm |
Pump connection | G 1½ | G 1½ | G 1½ | G 2 | - |
Pump connection (alternative designation) | RP 1 | RP 1 | RP 1 | - | - |
| DN 25 | DN 25 | DN 25 | - | - |
| - | - | - | RP 1 1/2 | - |
| - | - | - | DN 30 | - |
Display | No display | LED segment display | Graphic colour display (2 inches) | Graphic colour display (4.3 inches) | - |
Comment | Change piping | Change piping | Change piping | Change piping | - |
Function | |
Control mode | Constant speed (3 speed stages) | Constant speed (3 speed stages) | - | - | - |
| - | Δp-c for constant differential pressure | Δp-c for constant differential pressure | Δp-c for constant differential pressure | - |
| - | Constant speed (n-const.) | Constant speed (n-const.) | Constant speed (n-const.) | - |
| - | - | T-const. for constant temperature control | T-const. for constant temperature control | - |
| - | - | - | Δp-v for variable differential pressure | - |
| - | - | - | Q limit for limiting the maximum volume flow | - |
| - | - | - | Dynamic Adapt plus | - |
| - | - | - | ΔT-const. for constant differential temperature control | - |
| - | - | - | Constant Q for constant volume flow control | - |
| - | - | - | Multi Flow Adaptation | - |
| - | - | - | Δ T-const. for constant differential temperature control | - |
| - | - | - | User-defined PID control | - |
Special features of the series | - | - | Key locking function | Key locking function | - |
| - | - | Reset function for electricity meter | - | - |
| - | - | Reset function to factory setting | - | - |
| - | - | Qmin for T const. control mode | - | - |
| - | - | Automatic detection of thermal disinfection | - | - |
| - | - | - | Heating/Cooling switching | - |
| - | - | - | Thermal desinfection | - |
| - | - | - | Night set back | - |
| - | - | - | Heat quantity measurement | - |
| - | - | - | Cooling quantity measurement | - |
| - | - | - | No-Flow Stop | - |
| - | - | - | Adjustable volume flow limiter | - |
| - | - | - | Ability to save and restore configured pump settings (3 restoration points) | - |
| - | - | - | Fault message and warning message in plain text including suggested remedy | - |
Multi pump operation | - | - | - | Main/Standby | - |
| - | - | - | Parallel operation | - |
Measurement value logging | - | - | - | Heat and cooling capacity measurement | - |
Display | - | Actual volume flow | Actual volume flow | Actual volume flow | - |
| - | Actual power consumption | Actual power consumption | Actual power consumption | - |
| - | - | Setpoint | Setpoint | - |
| - | - | Actual delivery head | Actual delivery head | - |
| - | - | Energy consumption | Energy consumption | - |
| - | - | Actual speed | - | - |
| - | - | Manually activated restart or pump venting function | - | - |
| - | - | Warning messages in plain text (display status: yellow) | - | - |
| - | - | Error messages in plain text (display: red) | - | - |
| - | - | Control mode | Control mode | - |
| - | - | Active influences (e.g. STOP) | Active influences (e.g. STOP) | - |
| - | - | - | Temperature (version “-R7”: current fluid temperature possible with Stratos MAXO temperature sensor) | - |
Display (can also be selected) | - | - | - | Speed | - |
| - | - | - | Heating quantity | - |
| - | - | - | Cooling quantity | - |
| - | - | - | Operating hours | - |
| - | - | - | Mains voltage | - |
| - | - | - | Warning message | - |
| - | - | - | Error message | - |
Pump venting function | - | Manual | Manual | Yes | - |
Dry-running detection | - | - | yes | yes | - |
Equipment | |
Thermal insulation shell | - | Yes | Yes | Yes | - |
Cold water insulation shell | - | - | - | As accessories | - |
Quick electrical connection | - | Wilo Connector | Wilo Connector | Wilo Connector | - |
Blocking-current proof motor | - | - | yes | - | - |
Key lock | - | - | yes | - | - |
Operating elements | - | Green button | Green button and back button | - | - |
Connectivity | |
Analogue signal as standard | - | - | 0-10 V (via BMS Connect module accessories) | - | - |
| - | - | - | 0-10 V | - |
| - | - | - | 2-10 V | - |
| - | - | - | 4-20 mA | - |
| - | - | - | 0-20 mA | - |
| - | - | - | PT1000 | - |
Digital output | - | - | SSM/SBM (via BMS Connect module accessories) | - | - |
| - | - | - | SSM | - |
| - | - | - | SBM | - |
Digital input | - | - | Ext. OFF/Ext. MIN/ Ext. MAX (via BMS Connect module accessories) | - | - |
| - | - | - | Ext. OFF | - |
| - | - | - | Ext. MIN | - |
| - | - | - | Ext. MAX | - |
| - | - | - | MANUAL (BMS-OFF) | - |
| - | - | - | Key lock | - |
| - | - | - | Switchover between heating/cooling mode | - |
Bus communication via additional accessories | - | - | - | BACnet MS/TP | - |
| - | - | - | LON | - |
| - | - | - | Modbus RTU | - |
| - | - | - | CANopen | - |
| - | - | - | PLR | - |
| - | - | - | BACnet IP | - |
| - | - | - | Modbus TCP | - |
Access via the Wilo-Assistant app | - | - | Via accessory Wilo-Smart Connect Module BT | No | - |
Connection for Wilo-Smart Cloud | - | - | - | Via Wilo-Smart Gateway | - |
wire data exchange and remote operation | - | - | Via accessories Wilo-Smart Connect Module BT | Bluetooth | - |
Motor data | |
Phases | 1 | 1 | 1 | 1 | 1 |
Mains connection | 1~230 V, 50 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50 Hz |
Energy efficiency index (EEI) %%fn=footnote%% | - | - | - | ≤0.19 | - |
Min current | - | - | - | 0.11 A | - |
Max current | - | - | - | 1.05 A | - |
Rated power | 64.4 W | 30 W | 30 W | 133 W | - |
Min. speed | 1000 1/min | 700 1/min | 700 1/min | 750 1/min | - |
Max. speed | 1900 1/min | 4200 1/min | 4200 1/min | 3600 1/min | - |
Power consumption | - | 4 W | 3 W | 7 W | - |
Power consumption | 99 W | 40 W | 40 W | 160 W | - |
Emitted interference | EN 61000-6-3 | EN 61000-6-3 | EN 61000-6-3 | EN 61800-3;2004+A1;2012 /residential area (C1) | - |
Interference resistance | EN 61000-6-2 | EN 61000-6-2 | EN 61000-6-2 | EN 61800-3;2004+A1;2012 /industrial environment (C2) | - |
Electromagnetic compatibility | EN 61800-3 | EN 61800-3 | EN 61800-3 | - | - |
Insulation class | F | F | F | F | - |
Protection class | IP44 | IPX4D | IPX4D | IPX4D | - |
Materials | |
Bearing | Carbon, synthetic resin-impregnated | Carbon-graphite | Carbon-graphite | Carbon-graphite | - |
Pipe connection | |
Inlet connection | G 1½ | G 1½ | G 1½ | G 2 | DN 32 |
PN connection on suction side | PN 10 | PN 10 | PN 10 | PN 10 | PN 16 |
Outlet connection | G 1½ | G 1½ | G 1½ | G 2 | DN 32 |
PN connection on discharge side | PN 10 | PN 10 | PN 10 | PN 10 | PN 16 |
Dimension, weight | |
Length with packaging | 147 mm | 194 mm | 194 mm | 400 mm | - |
Length | 134 mm | 180 mm | 180 mm | 335 mm | - |
Height with packaging | 100 mm | 121 mm | 121 mm | 263 mm | - |
Height | 94 mm | 115 mm | 115 mm | 180 mm | - |
Width with packaging | 187 mm | 213 mm | 213 mm | 300 mm | - |
Width | 180 mm | 153 mm | 164 mm | 210 mm | - |
Gross weight, approx. | 2.7 kg | 1.9 kg | 2.1 kg | 8.6 kg | - |
Net weight, approx. | 2.6 kg | 1.6 kg | 1.8 kg | 7.5 kg | - |
Ordering information | |
Product description | Star-Z 25/6-3 | Yonos PICO-Z 25/0,5-6 180 | Stratos PICO-Z 25/0,5-6 | Stratos MAXO-Z 30/0,5-8 PN 10 | NRW 35 PN16 |
Brand | Wilo | Wilo | Wilo | Wilo | Biral |
EAN number | 4016322431244 | 4062679265858 | 4062679266084 | 4048482700120 | - |
Article number | 4047573 | 4255418 | 4255434 | 2164670 | - |
Price (excl. VAT) | EUR 871.- | EUR 865.- | EUR 1,308.- | EUR 2,500.- | - |