Search
Contact
E-mail
Catalog creation
My favorites
Wilo-VeroLine-IPL | Wilo
Your advantages
IPL

Your advantages

  • Integrated suction straightening vane
  • Pump feet drilled and tapped
  • Class 125 ANSI standard flanges
  • Suction and discharge pressure gauge tappings
  • Lifting eyes for easy installation

Recommended services

Eco-friendly features

  • Compact design of cast iron components for lowest possible weight
  • Sustainable and carbon-neutral production and processes in our European factories
Series description
VeroLine-IPL

Design

Single stage inline, flanged, long coupled, mechanical sealed dry rotor pump

Application

Hot Water Heating Systems

Closed Cooling Circuits

Air Conditioning

Industrial Circulation

Solar

Geothermal

Max. Flow: 400 GPM

Max. Head: 65 feet

Equipment/function

  • Coupled to motor via one piece coupling
  • Standard NEMA frame Baldor motor

Typekey

IPL 1.25‐21/50‐2

IPL

Inline flanged ended pump

1.25

Pipe connection in inch

21

Maximal head in feet

50

Maximal capacity in US gpm

2

Number of Poles4=1750 rpm, 2=3500rpm

Technical data

  • TEFC motors standard (ODP available)
  • Fluid Temp Range: 15°F to 250°F (-10°C to 120°C)
  • Max Amb Temp: 104°F (40 °C)
  • Electrical Connection: 1~115v, 230v3~208-230v, 460v, 575v
  • Flange connection: 1 ½" to 3" with ¼" pressure gauge tappings

Materials

  • Cast Iron, Cataphoresis Coated Volute
  • Engineered Composite Impeller
  • Stainless Steel Stub Shaft
  • 2-Part Epoxy Paint

Construction

  • Single stage low pressure centrifugal, inline design with mechanical seal
  • Baldor NEMA standard motors

Scope of delivery

  • Pump and motor (optionally pump end only)
  • Installation and operating instructions
Documents

Installation and operating instructions

Wilo-IPL

Article Number 2060099
Edition 05/06
Number of pages 17
Language en
PDF (649 KB)

Catalogue

IPL Catalog Pages

Number of pages 15
Language en
PDF (702 KB)

General overview

IPL Engineering Specifications

Number of pages 6
Language en
PDF (139 KB)

Certification booklet

Wilo-VeroLine-IP-E, Wilo-VeroTwin-DP-E, Wilo-VeroLine-IPL, Wilo-VeroTwin-DPL, Wilo-VeroLine-IPL-N, Wilo-VeroTwin-DPL-N, Wilo-VeroLine-IPH, Wilo-BM/BM-B/BM-S, Wilo-VeroLine-IP-Z

Article Number 2216679
Edition 2022-11
Number of pages 60
Language language neutral
PDF (22 MB)

Brochure

Wilo IPL Borchure

Number of pages 2
Language en
PDF (1 MB)

Data sheet

IPL Submittal Sheet

Number of pages 18
Language en
PDF (4 MB)
Product selection
Number of results: 35
Nominal flange diameter
Port-to-port length in inch L0
10 … 15 in (")
[35]
Phase
Number of poles
Product description Number of poles Nominal flange diameter Shaft seal type Port-to-port length L0Rated power P2Article number
IPL 1.5 16/80-4 1-115/230V
4
1½" ANSI Class 125
Q1Q1X4GG
13 in (")
0.33 hp
2705365
IPL 1.5 22/95-4 1-115/230V
4
1½" ANSI Class 125
Q1Q1X4GG
13 in (")
0.50 hp
2705367
IPL 1.5 29/95-4 1-115/230V
4
1½" ANSI Class 125
Q1Q1X4GG
13 in (")
0.75 hp
2711996
IPL 1.5 36/95-4 1-115/230V
4
1½" ANSI Class 125
Q1Q1X4GG
13 in (")
1.00 hp
2711998
IPL 1.5 36/95-4 3-208-230/460V
4
1½" ANSI Class 125
Q1Q1X4GG
13 in (")
1.00 hp
2712000
IPL 1.5 38/90-2 1-115/230V
2
1½" ANSI Class 125
Q1Q1X4GG
10 in (")
0.75 hp
2705037
IPL 1.5 46/95-2 1-115/230V
2
1½" ANSI Class 125
Q1Q1X4GG
10 in (")
1.00 hp
2712051
IPL 1.5 46/95-2 3-208-230/460V
2
1½" ANSI Class 125
Q1Q1X4GG
10 in (")
1.00 hp
2712053
IPL 1.5 59/100-2 1-115/230V
2
1½" ANSI Class 125
Q1Q1X4GG
10 in (")
1.50 hp
2702057
IPL 1.5 59/100-2 3-208-230/460V
2
1½" ANSI Class 125
Q1Q1X4GG
10 in (")
1.50 hp
2702058
IPL 1.25 21/50-4 1-115/230V
4
1¼" ANSI Class 125
Q1Q1X4GG
11 in (")
0.33 hp
2705363
IPL 2 18/125-4 1-115/230V
4
2" ANSI Class 125
Q1Q1X4GG
14 in (")
0.50 hp
2705369
IPL 2 23/140-4 1-115/230V
4
2" ANSI Class 125
Q1Q1X4GG
14 in (")
0.75 hp
2705371
IPL 2 28/160-4 1-115/230V
4
2" ANSI Class 125
Q1Q1X4GG
14 in (")
1.00 hp
2712012
IPL 2 28/160-4 3-208-230/460V
4
2" ANSI Class 125
Q1Q1X4GG
14 in (")
1.00 hp
2702014
IPL 2 38/180-4 1-115/230V
4
2" ANSI Class 125
Q1Q1X4GG
14 in (")
1.50 hp
2702018
IPL 2 38/180-4 3-208-230/460V
4
2" ANSI Class 125
Q1Q1X4GG
14 in (")
1.50 hp
2712020
IPL 2 40/140-2 1-115/230V
2
2" ANSI Class 125
Q1Q1X4GG
11 in (")
1.00 hp
2705038
IPL 2 40/140-2 3-208-230/460V
2
2" ANSI Class 125
Q1Q1X4GG
11 in (")
1.00 hp
2705039
IPL 2 52/160-2 1-115/230V
2
2" ANSI Class 125
Q1Q1X4GG
11 in (")
1.50 hp
2702063
IPL 2 52/160-2 3-208-230/460V
2
2" ANSI Class 125
Q1Q1X4GG
11 in (")
1.50 hp
2702064
IPL 2 60/170-2 1-115/230V
2
2" ANSI Class 125
Q1Q1X4GG
11 in (")
2.00 hp
2712066
IPL 2 60/170-2 3-208-230/460V
2
2" ANSI Class 125
Q1Q1X4GG
11 in (")
2.00 hp
2712068
IPL 2.5 15/185-4 1-115V
4
2½" ANSI Class 125
Q1Q1X4GG
14 in (")
0.50 hp
2705373
IPL 2.5 17/215-4 1-115V
4
2½" ANSI Class 125
Q1Q1X4GG
14 in (")
0.75 hp
2712004
IPL 2.5 23/240-4 1-115/230V
4
2½" ANSI Class 125
Q1Q1X4GG
14 in (")
1.00 hp
2705375
IPL 2.5 23/240-4 3-208-230/460V
4
2½" ANSI Class 125
Q1Q1X4GG
14 in (")
1.00 hp
2705377
IPL 2.5 50/260-2 1-115/230V
2
2½" ANSI Class 125
Q1Q1X4GG
14 in (")
2.00 hp
2705042
IPL 2.5 50/260-2 3-208-230/460V
2
2½" ANSI Class 125
Q1Q1X4GG
14 in (")
2.00 hp
2715044
IPL 2.5 65/270-2 3-208-230/460V
2
2½" ANSI Class 125
Q1Q1X4GG
14 in (")
3.00 hp
2712059
IPL 3 20/300-4 1-115/230V
4
3" ANSI Class 125
Q1Q1X4GG
15 in (")
1.00 hp
2705381
IPL 3 20/300-4 3-208-230/460V
4
3" ANSI Class 125
Q1Q1X4GG
15 in (")
1.00 hp
2705383
IPL 3 26/360-4 1-115/230V
4
3" ANSI Class 125
Q1Q1X4GG
15 in (")
1.50 hp
2705387
IPL 3 26/360-4 3-208-230/460V
4
3" ANSI Class 125
Q1Q1X4GG
15 in (")
1.50 hp
2705389
IPL 3 56/400-2 3-208-230/460V
2
3" ANSI Class 125
Q1Q1X4GG
14 in (")
3.00 hp
2705047