Whether in the basement of a hotel, an industrial plant, an office building or in your own home – they work invisibly and reliably everywhere, so we hardly give them a second thought: Sewage pumps. Nevertheless, sewage pumps, or wastewater pumps and faecal pumps, are essential for ensuring that sewage is removed safely, hygienically and energy-efficiently in every situation. They are also perfectly tailored to your application. Here is an overview of the most important types of sewage pumps and their benefits.

Sewage pumps in wet well installation, stationary

Wet well installation is mainly used for larger submersible pumps in sewage pumping stations, sewage collection pumping stations or also in water treatment systems. Wet well installation means that pumps can be operated at least partially or also completely (submersible pumps) under water. The sewage pumps can be used submerged in continuous operation and non-immersed in short-time duty.

Here is a selection of wet-installed Wilo sewage pumps:

Wilo-Rexa BLOCWilo-Rexa SOLID-QWilo-EMUport CORE

Sewage pumps in dry well installation, stationary

Sewage pumps (also called centrifugal pumps) are installed in a dry room and the submersible pumps are not immersed in the sewage. The pump housing is not flooded.

Here is a selection of dry-installed Wilo sewage pumps:

Wilo-Rexa SUPRA-VWilo-Rexa BlocWilo-Rexa SOLID-QWilo-Rexa SUPRA-CWilo-EMUport CORE

Portable sewage pumps for dry well installation

These pumps can easily be carried to their intended site. These mobile pumps are immediately ready for use, especially for dewatering excavations or for emergency watering during flood control.

Here is a selection of portable Wilo sewage pumps:

Wilo-Padus PRO

Lifting units

If the sewage from a building cannot be transported away to the central sewage pipe with a sufficient gradient, lifting units must be used. Lifting units are sewage pumps that discharge the sewage that accumulates below the backflow level in a backflow-resistant manner or pump it to a higher level.

A reliable sewage lifting unit is therefore indispensable for the backwater-resistant discharge of all types of sewage.

Lifting units from Wilo

Wilo sewage lifting units are your ideal solution for the safe and clean disposal of wastewater and sewage below the sewer level. In addition, all of our lifting units for pumping faecal-free sewage comply with the requirements of DIN EN-2 12050-2. We also offer faecal lifting units in accordance with EN-1 12050-1 for pumping sewage containing faeces.

Here is a selection of Wilo lifting units:

Detached and semi-detached housesFor commercial propertiesFor municipal applications

Sewage pumps with macerator

Sewage pumps with macerators are used to simultaneously shred solids and pump out sewage. They are primarily used for the disposal of sewage with a high solids content - mostly in pressure drainage. The pump shreds the solids in the sewage so that the pump or other pumps in the system will not clog and the sewage can be transported without any problems.

Are you looking for a faecal pump with macerator tailor-made for your requirements?

Use the following links. The overview page shows you the suitable fields of application for grinder pumps and the respective series of Wilo pumps that are suitable for you.

read more

FAQ – frequently asked questions

What should you consider when choosing your sewage pump?

In general, there are a few parameters to consider when selecting and operating a sewage pump. Here are the most relevant ones.

Installation types

Submersible motor technology, which includes sewage pumps, has different installation types. These depend primarily on the application. Basically, there are three main types of set-ups:

  • Wet well installation, stationary
  • Wet well installation, portable
  • Dry well installation, stationary

Energy efficiency

Choose sewage pumps with motors of a higher efficiency class, such as IE4 or IE5. These motors have a higher efficiency and can thus save energy costs. This also gives you a quick return on investment (ROI) and the potentially higher purchase costs pay off several times over the life cycle of the pump through the energy cost savings. In addition, sewage pumps with a high efficiency class reduce CO2 emissions and contribute to sustainability.

Condition of the sewage

Another selection criterion is the condition of the sewage. Depending on the substances contained in the sewage, this should be taken into account in selecting the materials for the components to prevent damage in the long term.

read more

Coating of the components

If the sewage contains aggressive and or abrasive substances (e.g. high sand content in the pumped fluid or seawater), it is advisable to select a sewage pump with coatings for the pump housing and impeller. The Ceram coating from Wilo, for example, offers excellent durability and longevity.

read more

Maintenance costs

Last but not least, especially in commercial, industrial and municipal environments, you should consider the costs for maintenance and repair, as well as servicing, of the pump. They should be included in your overall calculations in addition to purchase costs and energy savings.

What quality advantages do Wilo sewage lifting units offer you?

Wilo sewage lifting units are compact, robust and durable. The lifting units are made of durable, high-quality materials and components.

How can Wilo sewage lifting units be installed?

Wilo sewage lifting units are easy to install and maintain. All you need is a power connection and an inlet for the sewage.

How do you determine if your sewage lifting unit is running smoothly?

Wilo sewage lifting units are reliable and powerful. They have a high delivery rate and can also transport solid components in the sewage without any problems. The lifting units are equipped with an intelligent control system that monitors operation and alerts in case of malfunctions.

Does a lifting unit cause unpleasant odours?

Wilo sewage lifting units prevent unpleasant odours in the cellar or in the building. They have an odour-tight design and an active carbon filter that neutralises the gases produced.