P160-TS
Techniniai duomenys | |
---|---|
Maitinimo įtampa | 1~230 V, 50 Hz |
Nominalioji galia P2 P2 | 500 W |
Valdymas | be dažnio keitiklio |
Įjungimo būdas | Tiesioginis tinkle (DOL) |
Elektromagnetinis suderinamumas | EN 61000 |
Standartinė jungtis | EN 1254 |
Montavimas | Montavimas ant grindų |
Eksploatavimo duomenys | |
---|---|
Didž. įtako slėgis | 8 bar |
Matmenys | |
---|---|
Matmenys H1 | 775,0 mm |
Matmenys H2 | 730,0 mm |
Matmenys H3 | 225,0 mm |
Dimensions H4 | 545,0 mm |
Dimensions H5 | 590,0 mm |
Matmenys L | 455,0 mm |
Produkto duomenys | |
---|---|
Gamintojas | Wilo |
Produkto žymėjimas | P160-TS |
Prekės numeris | 2819499 |
EAN numeris | 5013608000650 |
Spalva | žalias / sidabrinis / pilkas |
Mažiausias užsakymo kiekis | 1 |
Turimumas rinkoje | 2012-06-01 |
Pakuotė | |
---|---|
Pakuotės rūšis | Europinis padėklas |
Pakuotė | Transportavimo pakuotė |
Skaičius ant padėklo | 4 |
Kiekis kiekvienam sluoksniui | 4 |
Masė ir matmenys | |
---|---|
Ilgio matmuo su pakuote | 1000 mm |
Ilgis L | 455 mm |
Aukščio matmuo su pakuote | 925 mm |
Aukštis H | 775 mm |
Pločio matmuo su pakuote | 800 mm |
Plotis W | 350 mm |
Bendroji masė (apyt.) m | 52 kg |
Grynoji masė (apyt.) m | 37 kg |
The Wilo Comfort Twin System pressurisation units are designed for use on heating or chilled water systems and include 1 pump per system, each pump capable of up to and including 3.5, 6.0 and 8.0 bar cold fill pressures.
The unit is fitted with an 18 litre polypropylene break tank c/w type AB air gap to BS13077:2008 and water regulations 1999, Wras approved equilibrium ball float valve to BS1212 and a low water float switch and strainers for pump protection.
Each pump is fitted with a non return valve and quick release couplings for ease of maintenance. The two pressure transducers monitor each system pressure individually and feed 0-10v signals to the comfort controller.
Comfort Controller is complete with the following features:
- User friendly interface that has a 2 line LCD backlight display
- Healthy / fail LED
- Password protection
- System Fill for initial fill of system
- Pump check routine, that runs both pumps for 2 seconds if inactive for 7-90 days
- Pump trip and fail alarms
- System leak alarm
- Excessive starts alarm
- Alarm log
- Hours Run
- Connectivity: BACnet = RS485 interface, BACnet MS/TP protocol
2 wire BACnet
Volt Free Contacts are supplied with terminals for common, normally open and normally closed.
(5A, 230V)
Pump no.1 trip, Pump no. 1 run, High Pressure, Low Pressure, Excess starts, Low water and Boiler Interlock (NC only)
(10A, 230V)
To be selected from Power fail, Common alarm, Common pressure alarm
Standards Applied:
Low Voltage and Machinery Directive 2006/42/EC, EMC Directive EMC 2004/108/EC, BSEN809, BS7074-1 to 3, BS13077:2008 and water regulations 1999.
Techniniai duomenys | |
---|---|
Maitinimo įtampa | 1~230 V, 50 Hz |
Valdymas | be dažnio keitiklio |
Eksploatavimo duomenys | |
---|---|
Didž. įtako slėgis | 8 bar |
Informacija apie užsakymo pateikimą | |
---|---|
Plotis W | 350 mm |