Product design type | Glandless high-efficiency pump | Glandless premium smart-pump | Existing pump |
| | | |
| | | |
| | | |
Description | |
Product description | Stratos PICO 25/0,5-6 | Stratos MAXO 25/0,5-4 PN 10 | Stratos ECO 25/1-5-BMS |
Article number | 4244395 | 2164567 | 4092514 |
Series | Wilo-Stratos PICO | Wilo-Stratos MAXO | - |
Mains connection | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | - |
Port-to-port length | - | - | - |
Pump connection | G 1½ | G 1½ | G 1½ |
Pump connection (alternative designation) | RP 1 | RP 1 | RP 1 |
| DN 25 | DN 25 | DN 25 |
Display | Graphic colour display (2 inches) | Graphic colour display (4.3 inches) | - |
Comment | Fits without modifications
Additional accessories required, BMS functionality via optional Wilo-Connect module BMS | Fits without modifications
Additional accessories required, BMS functionality via optional Wilo-Connect module BMS | - |
Function | |
Control mode | Δp-v for variable differential pressure | Δp-v for variable differential pressure | - |
| Δp-c for constant differential pressure | Δp-c for constant differential pressure | - |
| Dynamic Adapt plus | Dynamic Adapt plus | - |
| Constant speed (n-const.) | Constant speed (n-const.) | - |
| - | Q limit for limiting the maximum volume flow | - |
| - | ΔT-const. for constant differential temperature control | - |
| - | T-const. for constant temperature control | - |
| - | Constant Q for constant volume flow control | - |
| - | Multi Flow Adaptation | - |
| - | Δ T-const. for constant differential temperature control | - |
| - | User-defined PID control | - |
Special features of the series | Night set back | Night set back | - |
| Mode for pressure-independent control valves (PICV) | - | - |
| Key locking function | Key locking function | - |
| Reset function for electricity meter | - | - |
| Reset function to factory setting | Reset function to factory setting | - |
| - | Heating/Cooling switching | - |
| - | Heat quantity measurement | - |
| - | Cooling quantity measurement | - |
| - | No-Flow Stop | - |
| - | Adjustable volume flow limiter | - |
| - | Ability to save and restore configured pump settings (3 restoration points) | - |
| - | Fault message and warning message in plain text including suggested remedy | - |
Multi pump operation | - | Main/Standby | - |
| - | Parallel operation | - |
Measurement value logging | - | Heat and cooling capacity measurement | - |
Display | Setpoint | Setpoint | - |
| Actual delivery head | Actual delivery head | - |
| Actual volume flow | Actual volume flow | - |
| Actual power consumption | Actual power consumption | - |
| Energy consumption | Energy consumption | - |
| Actual speed | - | - |
| Manually activated restart or pump venting function | - | - |
| Warning messages in plain text (display status: yellow) | Warning messages in plain text (display status: yellow) | - |
| Error messages in plain text (display: red) | Error messages in plain text (display: red) | - |
| Control mode | Control mode | - |
| Active influences (e.g. STOP) | Active influences (e.g. STOP) | - |
| - | Temperature (version “-R7”: current fluid temperature possible with Stratos MAXO temperature sensor) | - |
| - | Pump venting (display status: blue) | - |
Display (can also be selected) | - | Speed | - |
| - | Heating quantity | - |
| - | Cooling quantity | - |
| - | Operating hours | - |
| - | Mains voltage | - |
| - | Warning message | - |
| - | Error message | - |
Pump venting function | Manual | Yes | - |
Dry-running detection | yes | yes | - |
Equipment | |
Thermal insulation shell | Yes | Yes | - |
Cold water insulation shell | - | As accessories | - |
Quick electrical connection | Wilo Connector | Wilo Connector | - |
Blocking-current proof motor | yes | yes | - |
Particle filter | yes | yes | - |
Key lock | yes | yes | - |
Operating elements | Green button and back button | - | - |
Fluid temperature sensor | - | Integrated | - |
Connectivity | |
Analogue signal as standard | 0-10 V (via BMS Connect module accessories) | - | - |
| - | 0-10 V | - |
| - | 2-10 V | - |
| - | 4-20 mA | - |
| - | 0-20 mA | - |
| - | PT1000 | - |
Digital output | SSM/SBM (via BMS Connect module accessories) | - | - |
| - | SSM | - |
| - | SBM | - |
Digital input | Ext. OFF/Ext. MIN/ Ext. MAX (via BMS Connect module accessories) | - | - |
| - | Ext. OFF | - |
| - | Ext. MIN | - |
| - | Ext. MAX | - |
| - | MANUAL (BMS-OFF) | - |
| - | Key lock | - |
| - | Switchover between heating/cooling mode | - |
Bus communication via additional accessories | - | BACnet MS/TP | - |
| - | LON | - |
| - | Modbus RTU | - |
| - | CANopen | - |
| - | PLR | - |
| - | BACnet IP | - |
| - | Modbus TCP | - |
Access via the Wilo-Assistant app | Via accessory Wilo-Smart Connect Module BT | Yes | - |
Connection for Wilo-Smart Cloud | - | Via Wilo-Smart Gateway | - |
wire data exchange and remote operation | Via accessories Wilo-Smart Connect Module BT | Bluetooth | - |
Motor data | |
Phases | 1 | 1 | 1 |
Mains connection | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50 Hz |
Energy efficiency index (EEI) | ≤0,18 | ≤0,18 | - |
Min current | - | 0,11 A | - |
Max current | - | 0,58 A | - |
Rated power | 30 W | 69 W | 34 W |
Min. speed | 700 1/min | 750 1/min | 1400 1/min |
Max. speed | 4200 1/min | 2550 1/min | 3500 1/min |
Power consumption | 3 W | 7 W | 5,8 W |
Power consumption | 40 W | 80 W | 59 W |
Emitted interference | EN 61000-6-3 | EN 61800-3;2004+A1;2012 /residential area (C1) | EN 61000-6-3 |
Interference resistance | EN 61000-6-2 | EN 61800-3;2004+A1;2012 /industrial environment (C2) | EN 61000-6-2 |
Electromagnetic compatibility | EN 61800-3 | - | EN 61800-3 |
Insulation class | F | F | F |
Protection class | IPX4D | IPX4D | IP44 |
Sound-pressure level | - | - | - |
Materials | |
Material | Grey cast iron | Grey cast iron | Grey cast iron |
Impeller | PP-GF40 | PPS-GF40 | PP-GF40 |
Shaft | Stainless steel | Stainless steel | Stainless steel |
Bearing | Carbon, metal-impregnated | Carbon-graphite | Carbon, metal-impregnated |
Pipe connection | |
Inlet connection | G 1½ | G 1½ | G 1½ |
PN connection on suction side | PN 10 | PN 10 | PN 10 |
Outlet connection | G 1½ | G 1½ | G 1½ |
PN connection on discharge side | PN 10 | PN 10 | PN 10 |
Dimension, weight | |
Length with packaging | 194 mm | 400 mm | 222 mm |
Length | 180 mm | 335 mm | 186 mm |
Height with packaging | 121 mm | 263 mm | 214 mm |
Height | 114 mm | 180 mm | 185 mm |
Width with packaging | 213 mm | 300 mm | 208 mm |
Width | 165 mm | 210 mm | 180 mm |
Gross weight, approx. | 2,2 kg | 8,3 kg | 3,2 kg |
Net weight, approx. | 1,9 kg | 7,2 kg | 3,1 kg |
Ordering information | |
Product description | Stratos PICO 25/0,5-6 | Stratos MAXO 25/0,5-4 PN 10 | Stratos ECO 25/1-5-BMS |
Brand | Wilo | Wilo | Wilo |
EAN number | 4062679126159 | 4048482699189 | 4016322891451 |
Article number | 4244395 | 2164567 | 4092514 |