Wilo-Drain TS 40
Series description


Your advantages
- Simple handling thanks to low weight
- Attached float switch and plug (A version) enable ease of use
Construction
Submersible drainage pump
Application
Pumping of
- Sewage without faeces or long-fibre constituents
- Wastewater
Equipment/function
- A-model with float switch and plug
- Thermal motor monitoring
- Integrated non-return valve
- Hose connection
Scope of delivery
- Pump with 10 m connection cable and bare cable end
- A-model with float switch and plug
- Hose connection
- Installation and operating instructions
Type key
Example: | Wilo-Drain TS 40/10-A |
TS | Submersible drainage pump |
40 | Nominal diameter discharge port (Rp 1½) |
10 | Max. delivery head |
A | Version with float switch and plug |
Technical data
- Mains connection: 1~ 230 V, 50 Hz or 3~ 400 V, 50 Hz
- Protection class: IP68
- Max. immersion depth: 7 m
- Fluid temperature: 3 ... 35 °C
- Cable length: 10 m
- Pressure port: Rp 1½
Materials
- Motor housing: 1.4301
- Pump housing: PP-GF30
- Impeller: PP-GF30
- Shaft: 1.4404
- Seal:
- On motor side: SiC/SiC
- Fluid side: SiC/SiC
- Static gasket: NBR
Description/construction
Submersible drainage pump as submersible monobloc unit for stationary and portable wet well installation.
Hydraulics
The outlet on the pressure side is designed as a vertical threaded connection Rp 1½ with an integrated non-return valve. Semi-open channel impellers are the impeller type used.
Motor
Single-phase or three-phase current version surface-cooled motors with thermal motor monitoring. In the single-phase version, motor monitoring switches automatically. The waste heat is given off directly to the surrounding fluid via the housing components. As a result, these units must always be immersed for permanent or intermittent operation.
A sealing chamber protects the motor from fluid ingress. The filling fluid used is potentially biodegradable and environmentally safe.
The detachable connection cable has a length of 10 metres and has bare cable ends. A version is equipped with a float switch and plug.
Seal
Fluid-side and motor-side sealing is performed by bidirectional mechanical seals.
Duty chart
Wilo-Drain TS 40


Downloads


General overview 2020 International version
Edition | 2020 |
Version number | 1 |
Page format | 209.9 x 297.0 mm |
Number of pages | 78 |
PDF (48 MB)
Download
Wilo-Drain TS 40
Article Number | 2065337 |
Edition | 2017-03 |
Version number | 03 |
Page format | 209.9 x 297.0 mm |
Number of pages | 84 |
PDF (2 MB)
Download
Wilo-Drain TS 50/65 & TP 50/65
Article Number | 2046787 |
Edition | 2014-07 |
Version number | 08 |
Page format | 209.9 x 297.0 mm |
Number of pages | 208 |