Stratos MAXO-Z
Wet rotor circulator
The smart high-efficiency pump for domestic hot water circulation in large buildings with building management system.
- Intuitive operation by application-guided settings with the setting assistant plus the combination of a new display and control knob using the Green Button Technology.
- Highest standard of drinking water hygiene and energy efficiency with the new, innovative, intelligent T-const. control function.
- Optimal hygiene is ensured through thermal disinfection detection.
- Latest communication interfaces (e.g. Bluetooth) for connection to mobile devices and direct pump networking for multi-pump control via Wilo Net.
- A clearly arranged and spacious terminal box and the optimised Wilo-Connector ensure maximum convenience in electrical installation.

| Product description | Pump connection | Mains connection | Gross weight, approx. m | Pieces per pallet | Maximum operating pressure | Article number | |
|---|---|---|---|---|---|---|---|
Stratos MAXO-Z 1.25x3-25 145PSI1~115/230 | 1.25" | 1~115, 230-240 V, 50/60 Hz | 0.48 lb | 8 | 145 psi | 2164623 | |
Stratos MAXO-Z 1.25x3-35 145PSI1~115/230 | 1.25" | 1~115, 230-240 V, 50/60 Hz | 0.72 lb | 8 | 145 psi | 2164624 | |
Stratos MAXO-Z 3x3-40 145PSI | 3" ANSI Class 125 | 1~230-240 V, 50/60 Hz | 1.41 lb | 8 | 145 psi | 2164626 | |
Stratos-MAXO Z 2x3-35 145PSI | 2.00" | 1~230-240 V, 50/60 Hz | 0.85 lb | 8 | 145 psi | 2164625 |

Design
Smart glandless circulator with oval flange and round flange connection and EC motor with integrated electronic power adjustment
Application
Domestic hot water circulation systems of all kinds, hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.Equipment/function
Field of application
The pump facilitates an operation with highest system efficiency via precise setting of the control mode for the system-specific application (e.g. radiator, underfloor heating, ceiling cooling).
Heating
- Radiator
- Underfloor heating
- Ceiling heating
- Fan heater
- Hydraulic shunt
- Heat exchanger
Cooling
- Ceiling cooling
- Underfloor cooling
- Air-conditioning devices
- Hydraulic shunt
- Heat exchanger
Heating and cooling combined
- Automatic switchover
The following control modes are available depending on the selected application:
Control modes
- Constant speed (control mode)
- Δp-c for constant differential pressure
- Δp-v for variable differential pressure
- Dynamic Adapt plus for continuous (dynamic) adjustment of the delivery rate to the current requirement
- T-const. for constant temperature regulation
- ΔT for differential temperature control
- Constant Q for constant volume flow control
- Multi-Flow Adaptation: Total volume flow determination through the feeder pump for the needs-based supply of secondary pumps in the heating circuit distributors
- User-defined PID controller
Optional functions
- Q-limitmax. for limiting the maximum volume flow
- Q-limitmin. for limiting the minimum volume flow
- No-Flow Stop (zero-flow-deactivation)
- Automatic setback operation
- Index circuit evaluator (Δp-c control with external actual value sensor)
- Thermal disinfection detection
- Variable pitch of Δp-v pump curve
Manual settings
- Selection of the field of application using the Setup Guide
- Setting the related operating parameters
- Nominal duty point: direct input of calculated duty point at Δp-v
- Status display
- Setting and resetting the energy meters (heating and cooling)
- Pump venting function
- Key lock for disabling the settings
- Function for resetting the factory settings or the saved restoration points (parameter sets)
- Parameterising the analogue inputs
- Parameterising the binary inputs
- Parameterising the relay outputs
Automatic functions
- Power adjustment according to requirements for energy-efficient operation depending on the operating mode
- Setback operation
- Deactivation at zero flow (No-Flow Stop)
- Soft start
- Automatic troubleshooting routines (e.g. deblocking function)
- Switchover heating/cooling mode
- Full motor protection with integrated trip electronics
External control inputs and their functions
2 x analogue inputs:
- Signal types: 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, PT1000
- Applications: Remote adjustment of the setpoints in every control mode (except Multi-Flow Adaptation), sensor inputs for temperature, differential pressure or free sensor in user-defined PID-operating mode
2 x digital inputs:
- For potential-free control outputs or switch
- Parametrizable functions:
- Ext. Off
- Ext. Min
- Ext. Max
- MANUAL (BMS-OFF)
- Key lock
- Switchover between heating/cooling mode
Wilo Net for dual pump management of 2 single pumps, communication of several pumps with each other and pump-remote adjustment via gateway
Signal and display functions
- Display status operation display:
- Setpoint
- Actual delivery head
- Actual volume flow
- Power consumption
- Electric consumption
- Temperatures
- Status display LED: Faultless operation (green LED), pump communication (blue LED)
- Display status of display fault (display red):
- Error codes and error description in full text
- Remedial measures
- Display status of display warning (display yellow):
- Warning codes and description of the warning in full text
- Remedial measures
- Display status process indicator display (display blue):
- Pump venting
- Update procedure
- Display BMS communication (display blue):
- Summary of the active BMS parameters (baud rate, address,...)
- Collective fault signal SSM (potential-free changeover contact)
- Collective run signal SBM (potential-free normally open contact)
Data exchange
- Bluetooth interface for wireless data exchange and remote operation of the pump using a smartphone or tablet.
- Serial digital interface Modbus RTU for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module Modbus RTU).
- Serial digital interface BACnet MS/TP for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module BACnet MS/TP).
Equipment
- Various integrated communication interfaces and optionally usable CIF module plug-in position
- 5 cable inlets for connecting the communication interfaces
- Bluetooth interface
- High resolution graphic display with green button and 2 additional buttons
- User-friendly terminal room
- Integrated temperature sensor in the pump housing
- Quick electrical connection with optimized Wilo-Connector including a ½ NPT connection adapter for the power supply
Type key
Example: | Wilo-Stratos MAXO-Z 3x3-40 |
Stratos MAXO | High-efficiency pump, electronically controlled |
-Z | Single pump for domestic hot water circulation systems |
3 | Flange connection in inches |
3-40 | Continuously adjustable setpoint height 3-40 ft |
Minimum delivery head 3.3 ft | |
Maximum delivery head 39.4 ft | |
at Q = 0 US gpm |
Technical data
- Permissible temperature range
- Drinking water up to 3.57 mmol/l: 32 °F (0 °C) to 176 °F (+80 °C)
- Heating water: 14 °F (-10 °C) to 230 °F (+110 °C)
- Mains connection:
- 1~115 V, 50/60 Hz (depending on type),
- 1~230 V-240 V, 50/60 Hz
- Enclosure: Type 2
- Flange connection: 1.25, 2 and 3 inch
- Max. operating pressure: 145 psi
- Insulation class: F
- Emitted interference in acc. with: EN 61800-3:2004+A1:2012 / residential environment (C1)
- Interference resistance in acc. with: EN 61800-3:2004+A1:2012 / industrial environment (C2)
Materials
- Pump housing made of stainless steel
- Thermal insulation: polypropylene
- Impeller: Plastic
- Shaft: Stainless steel
- Bearing: carbon
Construction
- Smart glandless circulator with EC motor and integrated electronic power adjustment
- Green Button Technology and graphic display
- Motor protection with trip electronics
- Plug connection for functional extension with optional CIF module for building automation (BA)
- Impeller with three-dimensionally curved blades and plastic sealing tube made of carbon fibre composite material
Scope of delivery
- Pump
- Optimized Wilo-Connector with ½ NPT connection adapter
- 5x threaded cable gland M16 x 1.5
- Gaskets for 1.25 and 2 inch flange connection
- Installation and operating instructions
Options
NO VALUEAccessories
- PT 1000 (B) pipe contact sensor (for domestic hot water)
- PT 1000 (AA) sensor for installation in immersion well
- Differential pressure sensor
- Wilo CIF modules: Modbus RTU, BACnet MS/TP