Similar to figure
Stratos GIGA-D 50/1-14/0,8
Article number: 2170230
High-efficiency in-line twin-head pump with EC motor of energy efficiency class IE5 in accordance with IEC 60034-30-2 and electronic power adjustment in glanded pump construction. The pump is configured as a single-stage low-pressure centrifugal pump with flange connection and mechanical seal. The Stratos GIGA-D has been predominantly designed for pumping heating water (acc. to VDI 2035), cold water and water-glycol mixtures without abrasive substances in heating, air-conditioning and cooling systems.
Design:
- Single-stage low-pressure centrifugal pump with one-piece shaft in monobloc design
- Spiral housing in in-line design (suction and pressure ports with the same flanges in a line)
- PN 16 flange – drilled according to EN 1092-2
- Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor)
- Pump housing and motor flange with cataphoretic coating as standard
- Mechanical seal for pumping water up to Tmax. = +140 °C. A glycol admixture of 20 % to +40 % by volume is permitted up to T ≤ +40 °C. An alternative mechanical seal must be provided in water-glycol mixtures with glycol proportions > 40 % up to maximum 50 % by volume and a fluid temperature of > +40 °C up to maximum +120 °C or fluids other than water.
- Connection voltages: 3~480 V ±10 % 50/60 Hz; 3~440 V ±10 % 50/60 Hz; 3~400 V ±10 % 50/60 Hz; 3~380 V -5 % +10 % 50/60 Hz
Accessories:
- Mounting brackets for fixing to the foundation
- Blind flanges for twin-head pump housing
- Differential pressure sensor sets 0 – 10 V for pumps in ...–R1 version
- IR-Monitor
- IR-Stick
- IF module PLR
- IF module LON
- IF module Modbus
- IF module BACnet
- IF module CAN
Standard equipment:
- Green button manual operation level for:
- Pump On/Off
- Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
- Setpoint and speed adjustment
- Configuration of operating parameters
- Fault acknowledgement
- Pump display for displaying:
- Control mode
- Setpoint (e.g. differential pressure or speed)
- Error and warning messages
- Actual values (e.g. power consumption, actual value of the sensor)
- Operating data (e.g. operating hours, energy consumption)
- Status data (e.g. status of SSM and SBM relay)
- Device data (e.g. pump name)
- Operating mode (only for twin-head pump operation: main/standby operation, parallel operation)
- Status of the pressure values correction
Additional functions:
- Analogue interfaces 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, built-in dual pump management, adjustable time interval for pump cycling (with dual pump operation), two configurable signalling relays for operating and fault messages, configurable fault response adapted to HVAC applications, access disable on the pump, built-in full motor protection (PTC thermistor sensor) with trip electronics, condensation drain holes in the motor housing as standard (sealed in delivered condition), infrared interface for wireless communication with the operating and service unit Wilo-IR monitor and Wilo IR-Stick, plug-in position for Wilo IF modules Modbus, BACnet, CAN, PLR, LON for connecting to the building automation.
Operating Data | |
---|---|
Fluid temperature T | -20 °C |
Ambient temperature T | 0 °C |
Maximum operating pressure PN | 16 bar |
Note on dimensioning | 16 bar to 120 °C, 13 bar to 140 °C |
Minimum efficiency index (MEI) | 0.7 |
Drive | |
---|---|
Mains connection | 3~400 V, 50/60 Hz |
Motor efficiency class | IE5 |
Power consumption P1 max | 900 W |
Rated power P2 | 0.8 kW |
Max current Imax | 1.6 A |
Max. speed nmax | 3300 1/min |
Interference emission | EN 61800-3 |
Interference immunity | EN 61800-3 |
Insulation class | F |
Protection class motor | IP55 |
Motor protection | PTC integrated |
Materials | |
---|---|
Pump housing | Grey cast iron |
Impeller | PPS-GF40 |
Shaft | Stainless steel |
Shaft seal | AQ1EGG |
Lantern | 5.1301/EN-GJL-250 KTL-coated |
Installation dimensions | |
---|---|
Pipe connection on the suction side DNs | DN 50 |
Pipe connection on the discharge side DNd | DN 50 |
Port-to-port length L0 | 280 mm |
Ordering information | |
---|---|
Brand | Wilo |
Product description | Stratos GIGA-D 50/1-14/0,8 |
Net weight, approx. m | 84 kg |
Article number | 2170230 |