Article number: 4242334
Technical data
Hydraulic data
Maximum inlet pressure p inl 6 bar
Maximum operating pressure PN 16 bar
Number of pumps 3
Min. fluid temperature Tmin 3 °C
Max. fluid temperature Tmax 25 °C
Min. ambient temperature Tmin 5 °C
Max. ambient temperature Tmax 40 °C
Motor data
Mains connection 3~400 V, 50 Hz
Rated power P2 7.5 kW
Rated current IN 13.5 A
Power factor cos φ100 0.88
Rated speed n 2900 1/min
Protection class switchgear IP54
Diesel engine
Air volume flow cooling 710 m³/h
Cooling method Air
Cylinder capacity 0.851 l
Cylinder number 2
Rated power 10250 W
Rated speed 2900 1/min
Materials
Pump housing Grey cast iron
Impeller
Shaft Stainless steel
Gasket material EPDM
Pipework material Steel
Installation dimensions
Pipe connection on the suction side DNs DN 50
Pipe connection on the discharge side DNd DN 65
Product data
Brand Wilo
Product description SiFire-Easy-32/200-191-7,5/10,5EDJ
Article number 4242334
EAN number 4062679090801
Colour Red/black/silver
Minimum order quantity 1
Date of sales availability 2020-09-20
Packaging
Packaging type Special pallet
Packaging property Sales packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1430 mm
Length L 1230 mm
Height with packaging 1659 mm
Height H 1529 mm
Width with packaging 1748 mm
Width W 1548 mm
Gross weight, approx. m 891 kg
Net weight, approx. m 861 kg
Tender text

Pressure boosting system as a fully automatic compact unit for fire fighting purposes in accordance with EN 12845.

Consisting of 2 pumps (main/standby) with horizontal base frame - EN 733 - with spacer coupling, one with an electric motor and one with a diesel motor and multistage vertical electric jockey pump, diaphragm pressure vessel (capacity: 20 l) and one switch cabinet per pump, fixed to a robust support structure.

Model EC-Fire E for the electric motor and model EC-Fire D for the diesel motor, both equipped with Easy Controller, plus model EC-Fire J for the jockey pump, solid construction made of special profiled parts with cut-outs for forklift trucks and hooks to ensure trouble-free, safe transportation. Height-adjustable bracket for the outlet manifold, special base plate for the diesel motor which reduces the transfer of vibrations considerably and increases the reliability and service life.

A circuit with dual pressure switch, pressure gauge, non-return valve, valve (secured from use by unauthorised personnel) for the main pump and standby pump for automatic start. The cables are concealed in the construction and protected against bumps and cuts. Equipped with a diaphragm installed directly on the main/standby pump housing as standard, to prevent overheating in the event of zero flow.

Only for the model with diesel motor: Fuel tank with level sensor and sufficient volume for six hours of autonomous operation, as well as 2 batteries on the base frame and battery charging units on the EC-Fire switch cabinet.

Independent anti-vibration base frame for the diesel motor pump.

One switchgear EC-Fire E and one EC-Fire D plus EC-Fire J for fire extinguishing systems in accordance with EN 12845.

Switchgears integrated in a sheet metal enclosure in accordance with protection class IP54.

Optimum regulation and ease of use by EC-Fire control with direct display of the current operating status, with symbol-based multilingual LCD display, easy user interface with simple menu navigation, buttons for quick setting of parameters. Communicative controller for monitoring system operation.

The system has been mounted on the base frame with wires and pipes are ready for connection.

Inlet pressure:

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum pumping head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For the main/standby pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 350 m³/h (97 l/s) system configuration for the main/standby pump.

Switchgears/control devices for fire water supply systems

Wilo-Control EC-Fire E (main pump with electric motor)

Hardware:

Fully electronic central control unit, installed in a painted steel enclosure, protection class IP54, control and display devices on the front door

Features and functions:

The design of the control device depends on the power of the connected pump (start via DOL or star-delta connection). The device comprises the following components:

  • Main switch: For switching the switchgear on and off. (For unauthorised use in the event of a fire)
  • Display: Display built into the door of the switch cabinet for operation and display purposes. Shows the operating data and the operating status of the pump and the controller using symbols. Menus are selected and parameters entered using the buttons on the front door
  • Microprocessor: Microprocessor PLC realised by programming, power supply unit and I/O wiring. The configuration of the programming depends on the system and the sprinkler system
  • Indicators: Long-life signal lamps indicate the operational readiness, motor operation and operation of the pump, the activation of the pressure switch and float switch, a false start, manual start and manual stop
  • Buttons: Buttons for manual start and manual stop, the lamp test and menu selection
  • Fuse protection: Fuses which tolerate the starting current for at least 20 s
  • Motor startup: Contactor for direct-on-line starting, up to 22 kW, for higher power levels start via star-delta connection
  • Motor protection: Only for signalling
  • Monitoring of the water supply: By means of a float switch to ensure a minimum water level of 2/3 of the supply tank is always maintained
  • Performance monitoring: Power supply and performance of the pump
  • Combined signal report: All types of error are displayed via a common error indicator
  • Individual signal report: The important false start error message is displayed via an individual error indicator
  • Error message and acknowledgement: All error messages are displayed via LEDs, shown in the display as an error code and must be acknowledged

Software:

  • Factory-programmed for fully automatic operation
  • Information regarding voltage, electric current and power of the pump
  • Menu navigation with clear text display

Conforms to the following standards:

  • Fixed Firefighting Systems - Automatic Sprinkler Systems - (EN 12845), part for pumps with electric motor
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Controlgear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC - Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC - Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo EC-Fire E control devices can be used to control pumps with an electric motor, sensors for pump management and the level of information. The microprocessor-controlled switchgear is used to control and regulate all required functions of a pressure boosting system according to EN 12845, for test purposes or actual sprinkler events.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

If a large amount of water is requested due to the opening of one or more circuits or due to a defective sprinkler, the pressure in the system decreases. As a result, the main pump is started using switchgear. If the electric main pump does not start in systems with multiple pumps (for example due to problems with the power supply), the pressure drop will activate the pressure switch of the standby pump, which starts this pump. In some cases, two or more electric pumps can be used.

As soon as the sprinkler circuit or gate valve, via which the sprinkler heads are supplied, is closed, pressure is built up in the system. The stop buttons on the front door must then be pressed to stop the pump.

Wilo-Control EC-Fire D (main pump with diesel motor)

Hardware:

Fully electronic central control unit, installed in a painted steel enclosure, protection class IP54, control and display devices on the front door

Features and functions:

The design of the control device depends on the power of the connected pump. The device comprises the following components:

  • Main switch: For switching the switchgear on and off. (For unauthorised use in the event of a fire)
  • Display: Display built into the door of the switch cabinet for operation and display purposes. Shows the operating data and the operating status of the pump and the controller using symbols. Menus are selected and parameters entered using the buttons on the front door
  • Microprocessor: Microprocessor PLC realised by programming, power supply unit and I/O wiring. The configuration of the programming depends on the system and the sprinkler system
  • Indicators: Longlife signal lamps which indicate the following: Operation of the pump, activation of the pressure switch, activation of the float switch, deactivation of automatic mode, deactivation of the motor heater, temperature alarm, oil pressure alarm, false start, belt alarm, low fuel level, running battery charger, low battery status, battery charger alarm, manual stop
  • Buttons: Push button for manual stop, manual start battery A, manual start battery B, lamp test and acknowledgement of alarms and warning messages, as well as menu selection
  • Fuse protection: Fuses for heating and battery charging unit in the switchgear
  • Motor startup: Automatically via 2 alternating batteries or directly with the start button on the front panel
  • Motor protection: Monitoring of typical operating parameters of the diesel motor (temperature, oil pressure, etc.) without stopping
  • Performance monitoring: Speed monitoring of the diesel engine
  • Battery monitoring: Monitoring of charging voltage, charging current and charging errors
  • Monitoring of the water supply: By means of a float switch to ensure a minimum water level of 2/3 of the supply tank is always maintained
  • Monitoring of the power supply: Error message from the battery charging unit in the event of a failure of the power supply
  • Combined signal report: All types of error are displayed via a common error indicator
  • Individual signal report: Important individual errors are indicated via individual error indicators
  • Error message and acknowledgement: All error messages are indicated by LEDs, and must be acknowledged

Software:

  • Factory-programmed for fully automatic operation
  • Information regarding motor speed, charging voltage and charging current.
  • Menu navigation with clear text display

Conforms to the following standards:

  • Fixed Firefighting Systems - Automatic Sprinkler Systems - (EN 12845), part for pumps with diesel motor
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Controlgear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC - Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC - Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo EC-Fire D control devices can be used to control pumps with a diesel motor, sensors for pump management and the level of information. The microprocessor-controlled switchgear is used to control and regulate all required functions of a pressure boosting system according to EN 12845, for test purposes or actual sprinkler events.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump. The pressure in the system decreases if a large quantity of water is requested due to the opening of one or more circuits or due to a defective sprinkler. As a result, the main pump is started using switchgear.

As soon as the sprinkler circuit or gate valve, via which the sprinkler heads are supplied, is closed, pressure is built up in the system. The stop buttons on the front door must then be pressed to stop the pump.

Wilo-Control EC-Fire J (jockey pump with electric motor)

Hardware:

Fully electromechanical control unit, installed in a painted steel enclosure, protection class IP54, control devices and buttons on the front door

Features and functions:

The design of the control device depends on the power of the connected pump. The device comprises the following components:

  • Main switch: For switching the switchgear on and off
  • Indicators: Longlife signal lamps, which indicate the operational readiness of the pump, operation of the pump and collective errors
  • Switches: Rotary switch for setting the manual mode or automatic mode
  • Motor startup: Direct contactor
  • Motor protection: Switch for protection against short-circuits and overloads
  • Individual signal report: Motor error message (short-circuit, overload)
  • Error message and acknowledgement: The motor error message is indicated via corresponding LEDs. The error is acknowledged when the motor protection switch is restarted

Conforms to the following standards:

  • Fixed Firefighting Systems - Automatic Sprinkler Systems - (EN 12845), part for jockey pumps
  • Electrical Equipment of Machines (EN 60204-1)
  • Low-voltage Switchgear and Controlgear Assemblies (EN 61439-1 and EN 61439-2)
  • EMC - Electromagnetic Compatibility for Industrial Environments (EN 61000-6-2)
  • EMC - Emission Standard for Residential, Commercial and Light-Industrial Environments (EN 61000-6-3)

Function description:

Wilo-Control EC-Fire J units can be used to control jockey pumps with an electric motor and sensors according to EN 12845, as well as for test purposes and operation of the sprinkler system.

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

The jockey pump, which is used for pressure boosting, is started first and ensures that the system is filled with water and that it remains pressurised. It is activated in the event of a pressure drop in the system. A properly calibrated pressure switch is used for controlled starting and stopping procedures.

Operating Data
Max. delivery head Hmax 48.8 m
Number of pumps 3
Fluid temperature T 3 °C
Ambient temperature T 5 °C
Maximum operating pressure PN 16 bar
Maximum inlet pressure p inl 6 bar
Motor data
Mains connection 3~400 V, 50 Hz
Rated power P2 7.5 kW
Rated current IN 13.5 A
Power factor cos φ100 0.88
Rated speed n 2900 1/min
Protection class switchgear IP54
Materials
Pump housing Grey cast iron
Impeller
Shaft Stainless steel
Shaft seal BVEGG
Gasket material EPDM
Pipework material Steel
Installation dimensions
Pipe connection on the suction side DNs DN 50
Pipe connection on the discharge side DNd DN 65
Ordering information
Brand Wilo
Product description SiFire-Easy-32/200-191-7,5/10,5EDJ
Net weight, approx. m 861 kg
Article number 4242334
Documents

Installation and operating instructions

Wilo-SiFire Easy

Article Number 4206362
Edition 1801
Number of pages 116
Language de, en, fr
PDF (8 MB)

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Number of pages 451
Language ar, bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, lt, lv, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk
PDF (18 MB)

Wilo-SiFire Easy

Article Number 4206363
Edition 2019-12
Number of pages 116
Language de, en, fr
PDF (4 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (327 KB)
Accessory

Break tank (1)

Fittings (10)

Noise control (6)

Pipe installation (8)

Valves/accessories (1)

Alarm signal (1)

Operating/service units (1)

Maintenance/replacement (15)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Maintenance
Maintenance COMFORT SiFire EDJ
    
2219507

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance PREMIUM SiFire EDJ
    
2219560

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Includes wearing parts

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Commissioning
Commissioning SiFire EDJ
    
2219405

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

More suitable services

Service packages
Service Package L SiFire EDJ
    
2219490

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package L includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • Energy Solutions
  • WiloCare Premium
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Repairs
  • Extended Warranty
Service Package L SiFire EJ
    
2219486

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package M includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • WiloCare Comfort
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Energy Solutions
  • Repairs
  • Extended Warranty
Service Package S SiFire EDJ
    
2219481

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package S includes:

  • Installation check
  • Commissioning
  • Maintenance
  • WiloCare Basic
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Energy Solutions
  • Supervision
  • Repairs
  • Extended Warranty
Wilo-Live Assistant
Wilo-Live Assistant Service
    
2216415

The Wilo-Live Assistant is a technical advisor at your side during pump service. By using the Wilo-Live Assistant, our expert advisers can support you in the boiler or equipment room via video transmission – live and in real time. You use your smartphone to show the installation set-up, while the Wilo expert follows everything on their screen. They can see the components as well as other details and can thus determine where the fault or breakdown originates. We prevent downtime and ensure operational reliability of your pumps and systems!

The Wilo-Live Assistant includes:

  • Interactive live support via video chat
  • Direct contact with an expert
  • Just-in-time solution to ensure maximum operational reliability of your pumps and systems
Extended Warranty
Extended Warranty SiFire EDJ
    
2219464

In combination of a new pump or system Wilo offers an extended warranty of up to five years in combination with commissioning and maintenance by the Wilo Service.

Extended warranty includes:

  • Full protection and predictable cost security
  • Regular maintenance work by the Wilo Service
Supervision
Supervision SiFire EDJ
    
2219341

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation SiFire EDJ
    
2219376

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
System Optimisation
System Optimisation SiFire EDJ
    
2219271

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions SiFire EDJ
    
2219306

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair SiFire EDJ
    
2219476

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report