Article number : 2221267
Technical data
Hydraulic data
Minimum efficiency index (MEI) ≥0,4
Maximum operating pressure PN 16 bar
Note on dimensioning 16 bar to 120 °C, 13 bar to 140 °C
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 140 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Drive
Mains connection 3~400 V, 50/60 Hz
Number of poles 4
Motor efficiency class IE4
Power consumption P1 max 16,80 kW
Rated power P2 15 kW
Max current Imax 26,2 A
Emitted interference EN 61800-3
Interference resistance EN 61800-3
Insulation class F
Protection class motor IP55
Motor protection PTC integrated
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Grey cast iron
Shaft Stainless steel
Shaft seal Q1Q1X4GG
Lantern 5.1301/EN-GJL-250 KTL-coated
Approved liquids (other liquids upon request)
Heating water (as per VDI 2035) yes
Heat carrier oil Special version at additional charge
Cooling and cold water circulation systems yes
Water-glycol mixtures (at 20 – 40 vol. % glycol and fluid temperature ≤ 40 °C) yes
Installation dimensions
Port-to-port length L0 620 mm
Pipe connection on the suction side DNs DN 80
Pipe connection on the discharge side DNd DN 80

IL-E 80/315-15/4-S1

L1, L2, L3: Mains connection: 3~440 V ±10%, 50/60 Hz; 3~400 V ±10%, 50/60 Hz; 3~380 V -5%/+10%, 50/60 Hz
PE: Protective conductor connection
DDG: Connection for differential pressure sensor
In1 (1): Actual value input 0-10 V/0-20 mA; 2-10 V/4-20 mA
GND (2): Ground connection for In1 and In2
+ 24 V (3): DC voltage output for an external consumer/sensor. Max load 60 mA
In2: Setpoint input 0-10 V/0-20 mA; 2-10 V/4-20 mA
MP: Multi-pump, interface for dual pump management
Ext. off: Control input “Overriding Off”The pump can be switched on or off via an external, potential-free contact (24 V DC/10 mA).
SBM:* Potential-free collective run signal (changeover contact according to VDI 3814)
SSM:* Potential-free collective fault signal (changeover contact according to VDI 3814)
aux: External pump cycling (only with dual pump operation). Pump cycling can be performed using an external, potential-free contact (24 VDC/10 mA)
DIP switch: 1: Switchover between operation (O) and service mode (S)2: Activate/deactivate the menu for access disable
Optional: IF-Modules for connection to the building automation

* Load capacity of contacts for SBM and SSM:

min.: 12 V DC/10 mA

max.: 250 V AC/1 A

Product data
Brand Wilo
Product description CronoLine IL-E 80/315-15/4-S1
Article number 2221267
EAN number 4062679237770
Colour Green
Minimum order quantity 1
Date of sales availability 2023-06-30
Packaging
Packaging type Euro pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1200 mm
Length L 930 mm
Height with packaging 1200 mm
Height H 760 mm
Width with packaging 800 mm
Width W 467 mm
Gross weight, approx. m 322 kg
Net weight, approx. m 273 kg
Tender text

Glanded centrifugal pump with in-line design for pipe installation with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v).

Design:

  • Single-stage low-pressure centrifugal pump
  • Spiral housing in in-line design (suction and discharge ports with the same flanges in one line), flanges PN 16 – drilled acc. to EN 1092-2
  • Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor)
  • Pump housing and motor flange with cataphoretic coating as standard.
  • Mechanical seal S1 recommended for water-glycol mixtures with glycol proportions up to max. 50% by volume and a fluid temperature of -20 °C up to max. +90 °C to +110 °C and also if the water-glycol mixture contains oil.

Accessories:

  • Mounting brackets for fixing to the foundation
  • IR-Stick
  • IF module PLR
  • IF module LON
  • IF module Modbus
  • IF module BACnet
  • IF module CAN
  • Control system VR-HVAC
  • Control system CCe-HVAC
  • Control system SCe-HVAC
  • Differential pressure sensor (DDG)

Standard equipment:

  • One-button manual operation level for:
    • Pump On/Off
    • Setpoint and speed adjustment
    • Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
    • Selection of operating mode in dual-pump operation (main/standby operation, parallel operation)
    • Configuration of operating parameters
    • Fault acknowledgement
  • Pump display for indication of:
    • Control mode
    • Setpoint (e.g. differential pressure or speed)
    • Error and warning messages
    • Actual values (e.g. power consumption, actual value of the sensor)
    • Operating data (e.g. operating hours, energy consumption)
    • Status data (e.g. status of SSM and SBM relay)
    • Device data (e.g. pump name)

Additional functions

  • 1x “Overriding OFF” control input
  • 1x “External pump cycling” (effective only in twin-head pump operation)
  • 1x Analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for constant speed (DDC) or remote setpoint adjustment,
  • 1x Analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for actual value signal from pressure sensor
  • IR interface for wireless communication with Wilo-IR-Stick operating and service device,
  • Slot for Wilo IF modules for connection to the building automation system,
  • Configurable, potential-free fault and operating/standby signal
  • 1x Interface to dual-pump communication
  • Three-phase AC motor with frequency converter
  • Integrated dual-pump management
  • Adjustable time interval for pump cycling (in dual-pump operation)
  • Integrated full motor protection
  • Different operating modes for heating (HV) or air-conditioning (AC) applications
  • Access disable
  • Different operation levels: Standard/service
Operating data
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 140 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Maximum operating pressure PN 16 bar
Note on dimensioning 16 bar to 120 °C, 13 bar to 140 °C
Minimum efficiency index (MEI) ≥0,4
Drive
Mains connection 3~400 V, 50/60 Hz
Motor efficiency class IE4
Power consumption P1 max 16800 W
Rated power P2 15 kW
Max current Imax 26,2 A
Max. speed nmax 1470 1/min
Emitted interference EN 61800-3
Interference resistance EN 61800-3
Insulation class F
Protection class motor IP55
Motor protection PTC integrated
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Grey cast iron
Shaft Stainless steel
Shaft seal Q1Q1X4GG
Lantern 5.1301/EN-GJL-250 KTL-coated
Installation dimensions
Pipe connection on the suction side DNs DN 80
Pipe connection on the discharge side DNd DN 80
Port-to-port length L0 620 mm
Ordering information
Brand Wilo
Product description CronoLine IL-E 80/315-15/4-S1
Net weight, approx. m 273 kg
Article number 2221267
Documents

Installation and operating instructions

Wilo-CronoLine-IL-E (11-22 kW), Wilo-CronoTwin-DL-E (11-22 kW), Wilo-CronoBloc-BL-E (1,5-22 kW)

Article Number 2234255
Edition 2024-02
Number of pages 88
Language en
PDF (13 MB)

Wilo-CronoLine-IL-E (11-22 kW), Wilo-CronoTwin-DL-E (11-22 kW), Wilo-CronoBloc-BL-E (1,5-22 kW)

Article Number 2234256
Edition 2024-02
Number of pages 328
Language de, en, fr, nl
PDF (21 MB)

Consulting guide

Glanded pumps, single-stage, single-volute

Edition 2021-12
Number of pages 24
Language en
PDF (7 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (287 KB)
BIM/CAD
Accessory

Continuous, infinitely variable control, differential pressure-sensitive CCe-HVAC system (27)

Continuous, infinitely variable control, temperature-dependent CCe-HVAC system (20)

Continuous, infinitely variable control, differential pressure-sensitive SCe-HVAC system (23)

Continuous, infinitely variable control, temperature-dependent SCe-HVAC system (14)

Pipe installation, adapter fitting (5)

Wall fixation/installation on a base (1)

Pump control/accessories (21)

Pump control/Comfort control system (6)

Pump control/Smart control system (4)

Pump control/interface module (6)

Differential pressure detection (40)

Operating/service units (1)