Product design type | Glandless premium smart-pump | Glandless premium smart-pump | Glandless standard high-efficiency pump | Existing pump |
| | | | |
| | | | |
| | | | |
Description | |
Product description | Stratos MAXO 32/0,5-12 PN6/10 | Stratos MAXO 40/0,5-12 PN6/10 | Yonos MAXO 32/0,5-11 PN6/10 | Ecocirc XLplus 32-120 F |
Article number | 2164580 | 2164584 | 2210114 | E503270AA |
Series | Wilo-Stratos MAXO | Wilo-Stratos MAXO | Wilo-Yonos MAXO | - |
Mains connection | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | - |
Port-to-port length l0 | 220 mm | 250 mm | 220 mm | 220 mm |
Pump connection | DN 32 | DN 40 | DN 32 | - |
Display | Graphic colour display (4.3 inches) | Graphic colour display (4.3 inches) | LED segment display | - |
Comment | Fits without modifications
No SSM integrated, please check interface usage. Additonal functions (external on/off, external operation indication) can be added with the simple install of the Connect-Module. | Change piping
No SSM integrated, please check interface usage. Additonal functions (external on/off, external operation indication) can be added with the simple install of the Connect-Module. | Fits without modifications
No SSM integrated, please check interface usage. Additonal functions (external on/off, external operation indication) can be added with the simple install of the Connect-Module. | - |
Result summary | |
Function | |
Control mode | Δp-v for variable differential pressure | Δp-v for variable differential pressure | Δp-v for variable differential pressure | - |
| Δp-c for constant differential pressure | Δp-c for constant differential pressure | Δp-c for constant differential pressure | - |
| Q limit for limiting the maximum volume flow | Q limit for limiting the maximum volume flow | - | - |
| Dynamic Adapt plus | Dynamic Adapt plus | - | - |
| ΔT-const. for constant differential temperature control | ΔT-const. for constant differential temperature control | - | - |
| T-const. for constant temperature control | T-const. for constant temperature control | - | - |
| Constant Q for constant volume flow control | Constant Q for constant volume flow control | - | - |
| Multi Flow Adaptation | Multi Flow Adaptation | - | - |
| Δ T-const. for constant differential temperature control | Δ T-const. for constant differential temperature control | - | - |
| User-defined PID control | User-defined PID control | - | - |
| Constant speed (n-const.) | Constant speed (n-const.) | - | - |
| - | - | Constant speed (3 speed stages) | - |
Special features of the series | Heating/Cooling switching | Heating/Cooling switching | - | - |
| Night set back | Night set back | - | - |
| Heat quantity measurement | Heat quantity measurement | - | - |
| Cooling quantity measurement | Cooling quantity measurement | - | - |
| Key locking function | Key locking function | - | - |
| No-Flow Stop | No-Flow Stop | - | - |
| Reset function to factory setting | Reset function to factory setting | - | - |
| Adjustable volume flow limiter | Adjustable volume flow limiter | - | - |
| Ability to save and restore configured pump settings (3 restoration points) | Ability to save and restore configured pump settings (3 restoration points) | - | - |
| Fault message and warning message in plain text including suggested remedy | Fault message and warning message in plain text including suggested remedy | - | - |
Multi pump operation | Main/Standby | Main/Standby | - | - |
| Parallel operation | Parallel operation | - | - |
| - | - | Main/Standby (with Connect Module Yonos MAXO) | - |
Measurement value logging | Heat and cooling capacity measurement | Heat and cooling capacity measurement | - | - |
Display | Setpoint | Setpoint | Setpoint | - |
| Actual delivery head | Actual delivery head | - | - |
| Actual volume flow | Actual volume flow | - | - |
| Actual power consumption | Actual power consumption | - | - |
| Energy consumption | Energy consumption | - | - |
| Temperature (version “-R7”: current fluid temperature possible with Stratos MAXO temperature sensor) | Temperature (version “-R7”: current fluid temperature possible with Stratos MAXO temperature sensor) | - | - |
| Warning messages in plain text (display status: yellow) | Warning messages in plain text (display status: yellow) | - | - |
| Error messages in plain text (display: red) | Error messages in plain text (display: red) | - | - |
| Pump venting (display status: blue) | Pump venting (display status: blue) | - | - |
| Control mode | Control mode | - | - |
| Active influences (e.g. STOP) | Active influences (e.g. STOP) | - | - |
| - | - | Fault signals (error codes) | - |
Display (can also be selected) | Speed | Speed | - | - |
| Heating quantity | Heating quantity | - | - |
| Cooling quantity | Cooling quantity | - | - |
| Operating hours | Operating hours | - | - |
| Mains voltage | Mains voltage | - | - |
| Warning message | Warning message | - | - |
| Error message | Error message | - | - |
Pump venting function | Yes | Yes | - | - |
Dry-running detection | yes | yes | - | - |
Equipment | |
Thermal insulation shell | Yes | Yes | As accessory | - |
Cold water insulation shell | As accessories | As accessories | - | - |
Quick electrical connection | Wilo Connector | Wilo Connector | Wilo plug | - |
Blocking-current proof motor | yes | yes | yes | - |
Particle filter | yes | yes | yes | - |
Key lock | yes | yes | - | - |
Fluid temperature sensor | Integrated | Integrated | - | - |
Connectivity | |
Analogue signal as standard | 0-10 V | 0-10 V | - | - |
| 2-10 V | 2-10 V | - | - |
| 4-20 mA | 4-20 mA | - | - |
| 0-20 mA | 0-20 mA | - | - |
| PT1000 | PT1000 | - | - |
Digital output | SSM | SSM | - | - |
| SBM | SBM | - | - |
| - | - | SSM/SBM (via accessories Connect module Yonos MAXO) | - |
Digital input | Ext. OFF | Ext. OFF | - | - |
| Ext. MIN | Ext. MIN | - | - |
| Ext. MAX | Ext. MAX | - | - |
| MANUAL (BMS-OFF) | MANUAL (BMS-OFF) | - | - |
| Key lock | Key lock | - | - |
| Switchover between heating/cooling mode | Switchover between heating/cooling mode | - | - |
| - | - | Ext. OFF (via accessories Wilo-Connect module Yonos MAXO) | - |
Bus communication via additional accessories | BACnet MS/TP | BACnet MS/TP | - | - |
| LON | LON | - | - |
| Modbus RTU | Modbus RTU | - | - |
| CANopen | CANopen | - | - |
| PLR | PLR | - | - |
| BACnet IP | BACnet IP | - | - |
| Modbus TCP | Modbus TCP | - | - |
Access via the Wilo-Assistant app | Yes | Yes | - | - |
Connection for Wilo-Smart Cloud | Via Wilo-Smart Gateway | Via Wilo-Smart Gateway | - | - |
wire data exchange and remote operation | Bluetooth | Bluetooth | - | - |
Motor data | |
Phases | 1 | 1 | 1 | 1 |
Mains connection | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50 Hz |
Energy efficiency index (EEI) | ≤0.18 | ≤0.17 | ≤0.20 | - |
Min current Imin | 0.11 A | 0.2 A | 0.15 A | - |
Max current Imax | 1.42 A | 2.49 A | 1.33 A | - |
Rated power P2 | 266 W | 479 W | 230 W | - |
Min. speed nmin | 750 1/min | 650 1/min | 1000 1/min | - |
Max. speed nmax | 4400 1/min | 3600 1/min | 4800 1/min | - |
Power consumption P1 min | 7 W | 10 W | 10 W | - |
Power consumption P1 max | 320 W | 570 W | 305 W | - |
Emitted interference | EN 61800-3;2004+A1;2012 /residential area (C1) | EN 61800-3;2004+A1;2012 /residential area (C1) | EN 61800-3;2004+A1;2012 /residential area (C1) | - |
Interference resistance | EN 61800-3;2004+A1;2012 /industrial environment (C2) | EN 61800-3;2004+A1;2012 /industrial environment (C2) | EN 61800-3;2004+A1;2012 /industrial environment (C2) | - |
Insulation class | F | F | F | - |
Protection class | IPX4D | IPX4D | IPX4D | - |
Materials | |
Material | Grey cast iron | Grey cast iron | Grey cast iron | - |
Impeller | PPS-GF40 | PPS-GF40 | PPE/PS-GF30 | - |
Shaft | 1.4122, DLC-coated | 1.4028, DLC-coated | Stainless steel | - |
Bearing | Carbon, antimony-impregnated | Carbon, antimony-impregnated | Carbon-graphite | - |
Pipe connection | |
Inlet connection | DN 32 | DN 40 | DN 32 | DN 32 |
PN connection on suction side | PN 6/10 | PN 6/10 | PN 6/10 | PN 10 |
Outlet connection | DN 32 | DN 40 | DN 32 | DN 32 |
PN connection on discharge side | PN 6/10 | PN 6/10 | PN 6/10 | PN 10 |
Dimension, weight | |
Length with packaging | 600 mm | 600 mm | 400 mm | - |
Length L | 360 mm | 410 mm | 245 mm | - |
Height with packaging | 394 mm | 394 mm | 263 mm | - |
Height H | 220 mm | 250 mm | 272 mm | - |
Width with packaging | 400 mm | 400 mm | 300 mm | - |
Width W | 212 mm | 239 mm | 146 mm | - |
Gross weight, approx. m | 14.5 kg | 19.9 kg | 11 kg | - |
Net weight, approx. m | 11.1 kg | 16.4 kg | 9.2 kg | - |
Ordering information | |
Product description | Stratos MAXO 32/0,5-12 PN6/10 | Stratos MAXO 40/0,5-12 PN6/10 | Yonos MAXO 32/0,5-11 PN6/10 | Ecocirc XLplus 32-120 F |
Brand | Wilo | Wilo | Wilo | Lowara/Xylem |
EAN number | 4048482699561 | 4048482699608 | 4062679000718 | - |
Article number | 2164580 | 2164584 | 2210114 | E503270AA |