Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Wilo-CronoLine-IL-E | Wilo
Your advantages
Wilo-CronoLine-IL-E

Your advantages

  • Energy savings due to integrated electronic power adjustment
  • Optional interfaces for bus communication using plug-in IF-Modules
  • Simple operation with Green Button Technology and display
  • Integrated dual pump management
  • Integrated full motor protection (PTC thermistor sensor) with trip electronics

Environmentally friendly properties

  • Use of IE4 motor technology and hydraulics with an MEI ≥ 0.4 saves energy
  • Sustainable and carbon-neutral production and processes in our European factories
Series description
CronoLine-IL-E

Design

Electronically controlled glanded single pump in in-line design with flange connection and automatic power adjustment

Application

The pumping of heating water (in accordance with VDI 2035), chilled water and water-glycol mixtures without abrasive substances in heating, chilled water and cooling systems.

Equipment/function

Operating modes

  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • PID-Control
  • Constant speed (n=constant)

Manual operation level

  • Green button and display

Manual functions

  • Differential pressure setpoint setting
  • Setting the speed (manual control mode)
  • Setting the operating mode
  • Setting the pump ON/OFF
  • Configuration of all operating parameters
  • Fault acknowledgement

External control functions

  • "Overriding Off" control input
  • “External pump cycling” control input (only effective in twin-head pump operation)
  • Analogue input 0 – 10 V, 0 – 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 2 – 10 V, 4 – 20 mA for constant speed (DDC) and remote setpoint adjustment
  • Analogue input 0 – 10 V for actual value signal from pressure sensor
  • Analogue input 2 – 10 V, 0 – 20 mA, 4 – 20 mA for actual value signal from pressure sensor

Signal and display functions

  • Collective fault signal SSM
  • Collective run signal SBM

Data exchange

  • Infrared interface for wireless data exchange with IR-Stick
  • Plug-in position for Wilo IF-Modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation

Safety functions

  • Full motor protection with integrated trip electronics
  • Access disable

Dual pump management (twin-head pump or 2 x single pumps)

  • Main/standby operation (automatic fault-actuated switchover)
  • Pump cycling main/standby operation after 24 hours
  • Parallel operation
  • Parallel operation (efficiency-optimised peak-load activation and deactivation)

Typekey

Example

IL-E 50/190-11/2-R1

IL-E

In-line pump with electronic control

50

Nominal diameter DN of the pipe connection

190

Nominal impeller diameter

11

Rated power P2 in kW

2

Number of poles

R1

Version without pressure sensor

Technical data

  • Permissible temperature range of -20 °C to +140 °C
  • Mechanical seal for pumping water up to Tmax = +140 °C. Up to T ≤ +40 °C, a glycol admixture of 20 % to 40 % by volume is permissible. An alternative mechanical seal must be provided for water-glycol mixtures with a glycol content of > 40% to max. 50% by volume and a fluid temperature of > +40 °C to max. +120 °C or other fluids that differ from water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.
  • Mains connection
    • 3~440 V ±10 %, 50/60 Hz
    • 3~400 V ±10%, 50/60 Hz
    • 3~380 V -5% +10%, 50/60 Hz
  • Compliance with electromagnetic compatibility without additional measures:
    • Interference emission for residential environment according to EN 61800-3:2018
    • Interference immunity for industrial environments according to EN 61800-3:2018
  • Protection class IP55
  • Nominal diameter DN 40 to DN 200
  • Max. operating pressure 16 bar up to +120 °C, 13 bar up to +140 °C

Materials

  • Pump housing and lantern: EN-GJL-250
  • Impeller
    • Standard version: EN-GJL-200
    • Special version: Bronze CuSn 10
    • Special version: Stainless steel 1.4408
  • Shaft: 1.4122
  • Mechanical seal: AQEGG; other mechanical seals on request

Construction

Single-stage, low-pressure centrifugal pump in in-line design with

  • Mechanical seal
  • Flange connection
  • Lantern
  • Coupling
  • Drive with integrated electronic speed control

Scope of delivery

  • Pump
  • Installation and operating instructions

Options

  • …-R1 variant without differential pressure sensor
  • …-L1 variant with bronze impeller (at additional charge)
  • …-L4 variant with stainless steel impeller (at additional charge)

Accessories

  • 3 Mounting brackets with fixation material for installation on a base
  • Wilo-IR-Stick
  • IF-Module PLR for connecting to PLR/interface converter
  • IF-Module LON for connection to the LONWORKS network
  • IF-Module BACnet
  • IF-Module Modbus
  • CAN IF-Module
  • VR-HVAC control system
  • Control system CCe-HVAC
  • Control system SCe-HVAC
  • Differential pressure sensor (DDG)
Documents

Installation and operating instructions

Wilo-CronoLine-IL-E (11-22 kW), Wilo-CronoTwin-DL-E (11-22 kW), Wilo-CronoBloc-BL-E (1,5-22 kW)

Article Number 2234255
Edition 2024-02
Number of pages 88
Language en
PDF (13 MB)

Wilo-CronoLine-IL-E (11-22 kW), Wilo-CronoTwin-DL-E (11-22 kW), Wilo-CronoBloc-BL-E (1,5-22 kW)

Article Number 2234256
Edition 2024-02
Number of pages 328
Language de, en, fr, nl
PDF (21 MB)

Consulting manual

Glanded pumps, single-stage, single-volute

Article Number Wilo515021
Edition 2021-12
Number of pages 24
Language en
PDF (7 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (279 KB)

EAC

EAC 2215562

Number of pages 2
Language language neutral
PDF (227 KB)

EAC RU Д-DE.РА05.В.73495/22

Number of pages 3
Language language neutral
PDF (1 MB)

EAC RU C-DE.БЛ08.В.00901/20

Number of pages 4
Language language neutral
PDF (3 MB)
Product selection
Number of results: 197
Nominal flange diameter
Port-to-port length L0
340 … 800 mm
[197]
productversion
Mechanical seal
Product descriptionMEIIENominal flange diameterMechanical sealPort-to-port length L0Rated power P2PhaseArticle number
CronoLine IL-E 40/170-5,5/2
≥0.4
IE4
DN 40
AQ1EGG
340 mm
5.5 kW
3
2159314
CronoLine IL-E 40/170-5,5/2-R1
≥0.4
IE4
DN 40
AQ1EGG
340 mm
5.5 kW
3
2159362
CronoLine IL-E 40/170-5,5/2-R1-S1
≥0.4
IE4
DN 40
Q1Q1X4GG
340 mm
5.5 kW
3
2171030
CronoLine IL-E 40/170-5,5/2-S1
≥0.4
IE4
DN 40
Q1Q1X4GG
340 mm
5.5 kW
3
2171007
CronoLine IL-E 40/200-7,5/2
≥0.4
IE4
DN 40
AQ1EGG
440 mm
7.5 kW
3
2159315
CronoLine IL-E 40/200-7,5/2-R1
≥0.4
IE4
DN 40
AQ1EGG
440 mm
7.5 kW
3
2159363
CronoLine IL-E 40/200-7,5/2-R1-S1
≥0.4
IE4
DN 40
Q1Q1X4GG
440 mm
7.5 kW
3
2171031
CronoLine IL-E 40/200-7,5/2-S1
≥0.4
IE4
DN 40
Q1Q1X4GG
440 mm
7.5 kW
3
2171008
CronoLine IL-E 40/210-11/2
≥0.4
IE4
DN 40
AQ1EGG
390 mm
11 kW
3
2231556
CronoLine IL-E 40/210-11/2-R1
≥0.4
IE4
DN 40
AQ1EGG
390 mm
11 kW
3
2231558
CronoLine IL-E 40/210-11/2-R1-S1
≥0.4
IE4
DN 40
Q1Q1X4GG
390 mm
11 kW
3
2231559
CronoLine IL-E 40/210-11/2-S1
≥0.4
IE4
DN 40
Q1Q1X4GG
390 mm
11 kW
3
2231557
CronoLine IL-E 50/160-5,5/2
≥0.4
IE4
DN 50
AQ1EGG
340 mm
5.5 kW
3
2159316
CronoLine IL-E 50/160-5,5/2-R1
≥0.4
IE4
DN 50
AQ1EGG
340 mm
5.5 kW
3
2159364
CronoLine IL-E 50/160-5,5/2-R1-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
340 mm
5.5 kW
3
2171033
CronoLine IL-E 50/160-5,5/2-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
340 mm
5.5 kW
3
2171009
CronoLine IL-E 50/170-7,5/2
≥0.4
IE4
DN 50
AQ1EGG
340 mm
7.5 kW
3
2159317
CronoLine IL-E 50/170-7,5/2-R1
≥0.4
IE4
DN 50
AQ1EGG
340 mm
7.5 kW
3
2159365
CronoLine IL-E 50/170-7,5/2-R1-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
340 mm
7.5 kW
3
2171034
CronoLine IL-E 50/170-7,5/2-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
340 mm
7.5 kW
3
2171010
CronoLine IL-E 50/180-7,5/2
≥0.4
IE4
DN 50
AQ1EGG
440 mm
7.5 kW
3
2159318
CronoLine IL-E 50/180-7,5/2-R1
≥0.4
IE4
DN 50
AQ1EGG
440 mm
7.5 kW
3
2159366
CronoLine IL-E 50/180-7,5/2-R1-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
7.5 kW
3
2171035
CronoLine IL-E 50/180-7,5/2-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
7.5 kW
3
2171011
CronoLine IL-E 50/190-11/2
≥0.4
IE4
DN 50
AQ1EGG
440 mm
11 kW
3
2221346
CronoLine IL-E 50/190-11/2-R1
≥0.4
IE4
DN 50
AQ1EGG
440 mm
11 kW
3
2221348
CronoLine IL-E 50/190-11/2-R1-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
11 kW
3
2221349
CronoLine IL-E 50/190-11/2-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
11 kW
3
2221347
CronoLine IL-E 50/200-15/2
≥0.4
IE4
DN 50
AQ1EGG
440 mm
15 kW
3
2221342
CronoLine IL-E 50/200-15/2-R1
≥0.4
IE4
DN 50
AQ1EGG
440 mm
15 kW
3
2221344
CronoLine IL-E 50/200-15/2-R1-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
15 kW
3
2221345
CronoLine IL-E 50/200-15/2-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
15 kW
3
2221343
CronoLine IL-E 50/230-18,5/2
≥0.4
IE4
DN 50
AQ1EGG
440 mm
18.5 kW
3
2221354
CronoLine IL-E 50/230-18,5/2-R1
≥0.4
IE4
DN 50
AQ1EGG
440 mm
18.5 kW
3
2221356
CronoLine IL-E 50/230-18,5/2-R1-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
18.5 kW
3
2221357
CronoLine IL-E 50/230-18,5/2-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
18.5 kW
3
2221355
CronoLine IL-E 50/240-22/2
≥0.4
IE4
DN 50
AQ1EGG
440 mm
22 kW
3
2221350
CronoLine IL-E 50/240-22/2-R1
≥0.4
IE4
DN 50
AQ1EGG
440 mm
22 kW
3
2221352
CronoLine IL-E 50/240-22/2-R1-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
22 kW
3
2221353
CronoLine IL-E 50/240-22/2-S1
≥0.4
IE4
DN 50
Q1Q1X4GG
440 mm
22 kW
3
2221351
CronoLine IL-E 65/150-11/2
≥0.4
IE4
DN 65
AQ1EGG
430 mm
11 kW
3
2221358
CronoLine IL-E 65/150-11/2-R1
≥0.4
IE4
DN 65
AQ1EGG
430 mm
11 kW
3
2221360
CronoLine IL-E 65/150-11/2-R1-S1
≥0.4
IE4
DN 65
Q1Q1X4GG
430 mm
11 kW
3
2221361
CronoLine IL-E 65/150-11/2-S1
≥0.4
IE4
DN 65
Q1Q1X4GG
430 mm
11 kW
3
2221359
CronoLine IL-E 65/160-15/2
≥0.4
IE4
DN 65
AQ1EGG
430 mm
15 kW
3
2226302
CronoLine IL-E 65/160-15/2-R1
≥0.4
IE4
DN 65
AQ1EGG
430 mm
15 kW
3
2226304
CronoLine IL-E 65/160-15/2-R1-S1
≥0.4
IE4
DN 65
Q1Q1X4GG
430 mm
15 kW
3
2226305
CronoLine IL-E 65/160-15/2-S1
≥0.4
IE4
DN 65
Q1Q1X4GG
430 mm
15 kW
3
2226303
CronoLine IL-E 65/180-15/2
≥0.4
IE4
DN 65
AQ1EGG
475 mm
15 kW
3
2221370
CronoLine IL-E 65/180-15/2-R1
≥0.4
IE4
DN 65
AQ1EGG
475 mm
15 kW
3
2221372