CronoTwin-DL-E 80/200-22/2-R1

Data sheet

Materials
  • Pump housing
    5.1301, EN-GJL-250
  • Impeller
    5.1300, EN-GJL-200
  • Lantern
  • Shaft
    1.4122, X39CrMo17-1
Operating data
  • Min. fluid temperature T
    -20 °C
  • Max. fluid temperature T
    140 °C
  • Maximum operating pressure p
    16 bar
  • Max. ambient temperature T
    40 °C
  • Minimum efficiency index (MEI)
    0.4
Motor data
  • Mains connection
    3~440 V, 50 Hz
  • Motor efficiency class
    IE4
  • Emitted interference
    EN 61800-3
  • Interference resistance
    EN 61800-3
  • Rated power P2
    22.00 kW
  • Rated current IN
    38.70 A
  • Rated speed n
    2900 rpm
  • Max. speed nmax
    2900 rpm
  • Protection class motor
    IP55
Installation dimensions
  • Port-to-port length L0
    500 mm
  • Pipe connection on the suction side
    DN 80
  • Pipe connection on the pressure side
    DN 80
Information for order placements
  • Net weight, approx. m
    548 kg
  • Brand
    Wilo
  • Product description
    CronoTwin-DL-E 80/200-22/2-R1
  • Article number
    2153885

Dimensions and dimensions drawings

CronoTwin-DL-E 80/200-22/2-R1

CronoTwin-DL-E 80/200-22/2-R1
CronoTwin-DL-E 80/200-22/2-R1

Pump curves

CronoTwin-DL-E 80/200-22/2, 2-pole - individual operation

CronoTwin-DL-E 80/200-22/2, 2-pole - individual operation

CronoTwin-DL-E 80/200-22/2, 2-pole - parallel operation

CronoTwin-DL-E 80/200-22/2, 2-pole - parallel operation
CronoTwin-DL-E 80/200-22/2, 2-pole - individual operation
CronoTwin-DL-E 80/200-22/2, 2-pole - parallel operation

Wiring diagram

IL-E

IL-E

L1, L2, L3:Mains connection: 3~440 V ±10%, 50/60 Hz; 3~400 V ±10%, 50/60 Hz; 3~380 V -5%/+10%, 50/60 Hz
PE:Protective conductor connection
DDG:Connection for differential pressure sensor
In1 (1):Actual value input 0-10 V/0-20 mA; 2-10 V/4-20 mA
GND (2):Ground connection for In1 and In2
+ 24 V (3):DC voltage output for an external consumer/sensor. Max load 60 mA
In2:Setpoint input 0-10 V/0-20 mA; 2-10 V/4-20 mA
MP:Multi-pump, interface for dual pump management
Ext. off:Control input “Overriding Off”The pump can be switched on or off via an external, potential-free contact (24 V DC/10 mA).
SBM:*Potential-free collective run signal (changeover contact according to VDI 3814)
SSM:*Potential-free collective fault signal (changeover contact according to VDI 3814)
aux:External pump cycling (only with dual pump operation). Pump cycling can be performed using an external, potential-free contact (24 VDC/10 mA)
DIP switch:1: Switchover between operation (O) and service mode (S)2: Activate/deactivate the menu for access disable
Optional:IF-Modules for connection to the building automation

* Load capacity of contacts for SBM and SSM:

min.: 12 V DC/10 mA

max.: 250 V AC/1 A

IL-E

Ordering information

Information for order placements
  • Brand
    Wilo
  • Product description
    CronoTwin-DL-E 80/200-22/2-R1
  • EAN number
    4048482554082
  • Article number
    2153885
  • Gross weight, approx. m
    575.0 kg
  • Net weight, approx. m
    548 kg
  • Overall length L
    881.0 mm
  • Height without packaging H
    677 mm
  • Colour
    Green
  • Packaging property
    Transport packaging
  • Packaging type
    Europallet
  • Number per layer
    1
  • Width without packaging L
    792.0 mm
  • Minimum order quantity
    1
  • Pieces per pallet
    1

Tender text

Glanded twin-head pump with in-line design for pipe installation or installation on a base with built-in frequency converter for electronic control for constant or variable differential pressure (Δp-c/Δp-v), among other things.

Design:

  • Single-stage low-pressure centrifugal pump
  • Spiral housing in in-line design (suction and pressure ports with the same flanges in one line), flanges PN 16 – drilled acc. to EN 1092-2
  • Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor)
  • Pump housing and motor flange with cataphoretic coating as standard
  • Mechanical seal for water feed up to T=140 °C. A glycol admixture of 20 to 40% by vol. is permitted up to Tmax = +40 °C
  • Special mechanical seals for water-glycol mixtures deviating from the 20–40% glycol by volume and a fluid temperature of ≤ 40 °C or fluids other than water (additional charge).

Accessories:

  • Mounting brackets for fixing to the foundation
  • IR-Monitor
  • IF module PLR
  • IF module LON
  • IF module Modbus
  • IF module BACnet
  • IF module CAN
  • Control systems VR-HVAC/CCe-HVAC/SCe-HVAC
  • Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1

Standard equipment:

  • One-button manual operation level for:
    • Pump On/Off
    • Setpoint and speed adjustment
    • Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
    • Selection of operating mode in dual pump operation (main/standby operation, parallel operation)
    • Configuration of operating parameters
    • Fault acknowledgement
  • Pump display for displaying:
    • Control mode
    • Setpoint (e.g. differential pressure or speed)
    • Error and warning messages
    • Actual values (e.g. power consumption, actual value of the sensor)
    • Operating data (e.g. operating hours, energy consumption)
    • Status data (e.g. status of SSM and SBM relay)
    • Device data (e.g. pump name)

Additional functions:

  • Interfaces: Control input "Overriding Off", "External pump cycling", analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for control mode (DDC) or for remote setpoint adjustment, analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for actual value signal of the pressure sensor, Infrared interface for wireless communication with the operating and service unit Wilo-IR Stick/IR-Monitor, plug-in position for Wilo IF-Module for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for dual pump communication
  • Three-phase AC motor with frequency converter
  • Integrated dual pump management
  • Adjustable time interval for pump cycling
  • Integrated full motor protection
  • Different operating modes for heating mode (HV) or air-conditioning mode (AC)
  • Access disable
  • Different operation levels: Standard / Service
Materials
  • Pump housing
    5.1301, EN-GJL-250
  • Impeller
    5.1300, EN-GJL-200
  • Lantern
  • Shaft
    1.4122, X39CrMo17-1
Operating data
  • Fluid media
    Water
  • Min. fluid temperature T
    -20 °C
  • Max. fluid temperature T
    140 °C
  • Maximum operating pressure p
    16 bar
  • Max. ambient temperature T
    40 °C
  • Minimum efficiency index (MEI)
    0.4
Motor data
  • Emitted interference
    EN 61800-3
  • Interference resistance
    EN 61800-3
  • Mains connection
    3~440 V, 50 Hz
  • Rated power P2
    22000 W
  • Max. speed nmax
    2900 rpm
  • Rated current IN
    38.70 A
  • Protection class motor
    IP55
  • Insulation class
    F
  • Integrated full motor protection
    yes
Installation dimensions
  • Pipe connection on the suction side
    DN 80
  • Pipe connection on the pressure side
    DN 80
Information for order placements
  • Net weight, approx. m
    548 kg
  • Brand
    Wilo
  • Product description
    CronoTwin-DL-E 80/200-22/2-R1
  • Article number
    2153885

Downloads

Wilo-IL-E/DL-E/BL-E

Article Number 2112769-72, 2122801
Edition 1512
Version number 01
Page format A4
Number of pages 1

PDF (144 MB)

Download

Wilo-IL-E/DL-E/BL-E

Article Number 2112769-72, 2122801
Edition 1512
Version number 01
Page format A4
Number of pages 72

PDF (9 MB)

Download

Wilo-CronoLine-IL-E/DL-E/BL-E

Article Number 2160196
Edition 2017-12
Version number 03
Page format 209.9 x 297.0 mm
Number of pages 261

PDF (25 MB)

Download

REACH Regulation

Edition 2018-10
Page format 209.9 x 296.7 mm
Number of pages 4

PDF (581 kB)

Download

PDF: CronoTwin-DL-E 80/200-22/2-R1

Configure

Page selection

Format selection

Optional information

You can enter any personal information that you want to be displayed in the header.

Download